{"product_id":"goodman-1-5-ton-18-000-btu-multi-positional-heat-pump-split-system-15-2-seer2-r32","title":"Goodman - 1.5 Ton\/18,000 BTU - Multi-Positional - Heat Pump Split System - 15.2 SEER2 - R32 - GLZS5BA1810","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 1.5 Ton\/18,000 BTU - Multi-Positional - Heat Pump Split System - 15.2 SEER2 - R32 - GLZS5BA1810 \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Goodman Heat Pump Split System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, the Goodman Heat Pump Split System is a perfect choice for all of your heating and cooling needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to cover a smaller house in average climates\u003c\/li\u003e\n\u003cli\u003e1.5 ton, 15.2 SEER2 heat pump condenser\u003c\/li\u003e\n\u003cli\u003eR32: Complies with Clean Air Act New Refrigerant Requirements\u003c\/li\u003e\n\u003cli\u003eLow sound output\u003c\/li\u003e\n\u003cli\u003eFully charged for up to 15' of line set\u003c\/li\u003e\n\u003cli\u003eFactory-installed bi-flow filter drier\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eAir Handler\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e2 ton air handler\u003c\/li\u003e\n\u003cli\u003eElectric heat compatible\u003c\/li\u003e\n\u003cli\u003eOptimized for use with R-32 refrigerant\u003c\/li\u003e\n\u003cli\u003eMulti-speed, direct drive ECM blower motor\u003c\/li\u003e\n\u003cli\u003eMulti-positional (upflow, downflow, or horizontal)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-4x00{background-color:#ffffff;border-color:#000000;color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-4x00\"\u003eSKU\u003c\/th\u003e\n\u003cth class=\"tg-cly1\"\u003eGLZS5BA1810 \/ AMST24BU1300\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e215381159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e17,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eSEER2 (Efficiency)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eSystem Tonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman_Heat_Pump_Install_Manual_v2023_1.pdf?v=1727084167\" target=\"_blank\"\u003e\u003cstrong\u003eGSZH5 Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GSZH5_Spec_Sheet.pdf?v=1727084174\" target=\"_blank\"\u003e\u003cstrong\u003eGSZH5 Specifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"jtyg4s\" data-start=\"27\" data-end=\"387\"\u003e\n\u003cp data-start=\"29\" data-end=\"387\"\u003e\u003cstrong data-start=\"29\" data-end=\"85\"\u003eEfficient Year‑Round Comfort with Modern Refrigerant\u003c\/strong\u003e\u003cbr data-start=\"85\" data-end=\"88\"\u003eThe \u003cstrong data-start=\"94\" data-end=\"148\"\u003eGoodman GLZS5BA1810 1.5 Ton Heat Pump Split System\u003c\/strong\u003e delivers \u003cstrong data-start=\"158\" data-end=\"221\" data-is-only-node=\"\"\u003e15.2 SEER2 cooling and solid heating capacity (~18,000 BTU)\u003c\/strong\u003e using \u003cstrong data-start=\"228\" data-end=\"248\"\u003eR‑32 refrigerant\u003c\/strong\u003e, helping lower both your \u003cstrong data-start=\"274\" data-end=\"313\"\u003eenergy use and environmental impact\u003c\/strong\u003e compared with older refrigerants. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tnriyr\" data-start=\"389\" data-end=\"678\"\u003e\n\u003cp data-start=\"391\" data-end=\"678\"\u003e\u003cstrong data-start=\"391\" data-end=\"428\"\u003eReliable Single‑Stage Performance\u003c\/strong\u003e\u003cbr data-start=\"428\" data-end=\"431\"\u003eIts \u003cstrong data-start=\"437\" data-end=\"471\"\u003esingle‑stage scroll compressor\u003c\/strong\u003e provides \u003cstrong data-start=\"481\" data-end=\"527\" data-is-only-node=\"\"\u003edependable, consistent cooling and heating\u003c\/strong\u003e for smaller homes or zones without complex modulation or expensive controls—ideal for straightforward comfort. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l04xin\" data-start=\"680\" data-end=\"942\"\u003e\n\u003cp data-start=\"682\" data-end=\"942\"\u003e\u003cstrong data-start=\"682\" data-end=\"723\"\u003eSmartShift® Defrost for Quiet Heating\u003c\/strong\u003e\u003cbr data-start=\"723\" data-end=\"726\"\u003eBuilt‑in \u003cstrong data-start=\"737\" data-end=\"771\"\u003eSmartShift® defrost technology\u003c\/strong\u003e helps ensure heating cycles are \u003cstrong data-start=\"804\" data-end=\"842\" data-is-only-node=\"\"\u003equiet and reliable in cold weather\u003c\/strong\u003e, minimizing frost buildup and interruptions in performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vc2hvq\" data-start=\"944\" data-end=\"1236\"\u003e\n\u003cp data-start=\"946\" data-end=\"1236\"\u003e\u003cstrong data-start=\"946\" data-end=\"988\"\u003eDurable Weather‑Resistant Construction\u003c\/strong\u003e\u003cbr data-start=\"988\" data-end=\"991\"\u003eThe unit features a \u003cstrong data-start=\"1013\" data-end=\"1095\"\u003eheavy‑gauge galvanized‑steel cabinet with powder‑paint finish and louver guard\u003c\/strong\u003e, protecting components from rain, corrosion, and harsh outdoor conditions for long‑term reliability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bum3ak\" data-start=\"1238\" data-end=\"1524\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1524\"\u003e\u003cstrong data-start=\"1240\" data-end=\"1278\"\u003eService‑Friendly \u0026amp; Installer‑Ready\u003c\/strong\u003e\u003cbr data-start=\"1278\" data-end=\"1281\"\u003eFactory‑installed components like \u003cstrong data-start=\"1317\" data-end=\"1424\"\u003esuction‑line accumulator, crankcase heater, high‑capacity muffler, and service valves with gauge access\u003c\/strong\u003e help HVAC pros install and maintain the system efficiently. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jucux1\" data-start=\"1526\" data-end=\"1793\"\u003e\n\u003cp data-start=\"1528\" data-end=\"1793\"\u003e\u003cstrong data-start=\"1528\" data-end=\"1565\"\u003eQuiet Operation You’ll Appreciate\u003c\/strong\u003e\u003cbr data-start=\"1565\" data-end=\"1568\"\u003eWith a typical sound level around \u003cstrong data-start=\"1604\" data-end=\"1614\"\u003e70 dBA\u003c\/strong\u003e, this heat pump delivers cooling and heating without excessive noise, making it suitable for suburban homes or quiet residential settings. \u003cspan class=\"\" data-state=\"delayed-open\" aria-describedby=\"radix-_r_na_\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"zph4k0\" data-start=\"127\" data-end=\"392\"\u003e\n\u003cp data-start=\"129\" data-end=\"392\"\u003e\u003cstrong data-start=\"129\" data-end=\"157\"\u003eChange Air Filters Often\u003c\/strong\u003e – Check and replace your indoor air filter every 1–3 months to maintain strong airflow and protect coils from dust and debris. Dirty filters can drastically reduce system efficiency and comfort. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsmiym\" data-start=\"394\" data-end=\"623\"\u003e\n\u003cp data-start=\"396\" data-end=\"623\"\u003e\u003cstrong data-start=\"396\" data-end=\"423\"\u003eKeep Outdoor Unit Clear\u003c\/strong\u003e – Regularly remove leaves, grass clippings, and other debris around the condenser to ensure proper airflow and prevent blockages that reduce SEER2 performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5n6wx0\" data-start=\"625\" data-end=\"863\"\u003e\n\u003cp data-start=\"627\" data-end=\"863\"\u003e\u003cstrong data-start=\"627\" data-end=\"651\"\u003eClean Coils Annually\u003c\/strong\u003e – Both outdoor condenser and indoor evaporator coils should be cleaned at least once per year by a professional to maintain efficient heat transfer and avoid frozen coils. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ytw6xm\" data-start=\"865\" data-end=\"1093\"\u003e\n\u003cp data-start=\"867\" data-end=\"1093\"\u003e\u003cstrong data-start=\"867\" data-end=\"909\"\u003eInspect Refrigerant Lines \u0026amp; Insulation\u003c\/strong\u003e – Ensure R32 lines are intact, well‑insulated, and leak‑free; proper refrigerant conditions are critical for heat pump efficiency and capacity. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sn9qtg\" data-start=\"1095\" data-end=\"1292\"\u003e\n\u003cp data-start=\"1097\" data-end=\"1292\"\u003e\u003cstrong data-start=\"1097\" data-end=\"1129\"\u003eCheck Drain \u0026amp; Fan Components\u003c\/strong\u003e – Periodically clean the condensate drain line and pan to prevent clogs and check outdoor fan blades for debris or damage. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g0ph3v\" data-start=\"1294\" data-end=\"1481\"\u003e\n\u003cp data-start=\"1296\" data-end=\"1481\"\u003e\u003cstrong data-start=\"1296\" data-end=\"1324\"\u003eMaintain Unit Clearances\u003c\/strong\u003e – Trim vegetation and maintain ≈ 2 ft of space around the outdoor unit so airflow isn’t restricted during operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vnb5yx\" data-start=\"1483\" data-end=\"1820\"\u003e\n\u003cp data-start=\"1485\" data-end=\"1820\"\u003e\u003cstrong data-start=\"1485\" data-end=\"1531\"\u003eSchedule Professional Tune‑Ups Bi‑Annually\u003c\/strong\u003e – Have a licensed HVAC technician service the system before cooling and heating seasons to check pressures, electrical connections, reversing valve operation, and overall performance. This helps preserve SEER2 efficiency and prolong equipment life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"zph4k0\" data-start=\"127\" data-end=\"392\"\u003e\n\u003cp data-start=\"129\" data-end=\"392\"\u003e\u003cstrong data-start=\"129\" data-end=\"157\"\u003eChange Air Filters Often\u003c\/strong\u003e – Check and replace your indoor air filter every 1–3 months to maintain strong airflow and protect coils from dust and debris. Dirty filters can drastically reduce system efficiency and comfort. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsmiym\" data-start=\"394\" data-end=\"623\"\u003e\n\u003cp data-start=\"396\" data-end=\"623\"\u003e\u003cstrong data-start=\"396\" data-end=\"423\"\u003eKeep Outdoor Unit Clear\u003c\/strong\u003e – Regularly remove leaves, grass clippings, and other debris around the condenser to ensure proper airflow and prevent blockages that reduce SEER2 performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5n6wx0\" data-start=\"625\" data-end=\"863\"\u003e\n\u003cp data-start=\"627\" data-end=\"863\"\u003e\u003cstrong data-start=\"627\" data-end=\"651\"\u003eClean Coils Annually\u003c\/strong\u003e – Both outdoor condenser and indoor evaporator coils should be cleaned at least once per year by a professional to maintain efficient heat transfer and avoid frozen coils. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ytw6xm\" data-start=\"865\" data-end=\"1093\"\u003e\n\u003cp data-start=\"867\" data-end=\"1093\"\u003e\u003cstrong data-start=\"867\" data-end=\"909\"\u003eInspect Refrigerant Lines \u0026amp; Insulation\u003c\/strong\u003e – Ensure R32 lines are intact, well‑insulated, and leak‑free; proper refrigerant conditions are critical for heat pump efficiency and capacity. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sn9qtg\" data-start=\"1095\" data-end=\"1292\"\u003e\n\u003cp data-start=\"1097\" data-end=\"1292\"\u003e\u003cstrong data-start=\"1097\" data-end=\"1129\"\u003eCheck Drain \u0026amp; Fan Components\u003c\/strong\u003e – Periodically clean the condensate drain line and pan to prevent clogs and check outdoor fan blades for debris or damage. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g0ph3v\" data-start=\"1294\" data-end=\"1481\"\u003e\n\u003cp data-start=\"1296\" data-end=\"1481\"\u003e\u003cstrong data-start=\"1296\" data-end=\"1324\"\u003eMaintain Unit Clearances\u003c\/strong\u003e – Trim vegetation and maintain ≈ 2 ft of space around the outdoor unit so airflow isn’t restricted during operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vnb5yx\" data-start=\"1483\" data-end=\"1820\"\u003e\n\u003cp data-start=\"1485\" data-end=\"1820\"\u003e\u003cstrong data-start=\"1485\" data-end=\"1531\"\u003eSchedule Professional Tune‑Ups Bi‑Annually\u003c\/strong\u003e – Have a licensed HVAC technician service the system before cooling and heating seasons to check pressures, electrical connections, reversing valve operation, and overall performance. This helps preserve SEER2 efficiency and prolong equipment life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533438910538,"sku":"GLZS5BA1810 \/ AMST24BU1300","price":3238.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/goodman-split-gsxh5-amst_46_7c033e58-63ec-4cf5-9b02-e3db19222647.webp?v=1776875848","url":"https:\/\/wen0d6-q0.myshopify.com\/es\/products\/goodman-1-5-ton-18-000-btu-multi-positional-heat-pump-split-system-15-2-seer2-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}