{"product_id":"goodman-2-5-ton-60-000-btu-96-afue-gas-furnace-and-air-conditioner-system-downflow-14-3-seer2-r32","title":"Goodman - 2.5 Ton\/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 2.5 Ton\/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Downflow - 14.3 SEER2 - R32 - CAPTA3026B3 \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eA Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman furnace and air conditioning system is the perfect choice for all of your heating and cooling needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll-Aluminum Coil: Goodman's evaporator coils maximize surface area and optimize heat transfer for efficient comfort by using a reliable all-aluminum design complete with sine fins and grooved tubes.\u003c\/li\u003e\n\u003cli\u003eInternal Thermostatic Expansion Valve: Goodman's CAPTA units have a factory-installed internal thermostatic expansion valve, which streamlines installation and maintains ideal refrigerant flow for your system.\u003c\/li\u003e\n\u003cli\u003eCabinet Durability: Providing superior longevity and efficiency, CAPTA units have a galvanized, embossed, and insulated cabinet that protects the coil and prevents air leakage.\u003c\/li\u003e\n\u003cli\u003eCondensate Management: Keeping your system sage and operational, the CAPTA units feature a foil-faced insulation to inhibit the formation of condensate and a rust-resistant, DecaBDE-free thermoplastic drain pan secondary drain connections. The drain pan is UV-resistant.\u003c\/li\u003e\n\u003cli\u003eR32 Compatibility: Complies with Clean Air Act New Refrigerant Requirements.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wa1i\" colspan=\"2\"\u003e2.5 Ton 14.3 SEER2 Goodman Air Conditioner Condenser - R32\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGLXS4BA3010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e170.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eReplaces\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGSXN403010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eProduct Features\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eNew Refrigerant Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e30,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHorsepower\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1\/6 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSEER2\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e14.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e208\/230v 1 Phase 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e15.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e32\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e29\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e29\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/glxs4b_spec_sheet_6b26cb6d-15e2-4254-a82d-b7ca4077f5e6.pdf?v=1727948877\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003e\u003cstrong\u003eGLXS4B Specifications\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/install_Manual_5eb964ff-5cc2-40ad-ac68-740f9017f179.pdf?v=1727948873\" target=\"_blank\"\u003e\u003cstrong\u003eGLXS4B Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman_Vertical_Coil_Install_Manual_v3.2023_a27bd171-c979-47ff-916d-74c9a52a4b22.pdf?v=1727948869\" target=\"_blank\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-CAPTA32-coil_spec.pdf?v=1727948869\" target=\"_blank\"\u003e\u003cstrong\u003eCAPTA Specifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1wzgkcg\" data-start=\"27\" data-end=\"214\"\u003e\n\u003cp data-start=\"29\" data-end=\"214\"\u003e\u003cstrong data-start=\"29\" data-end=\"66\"\u003eMatched Heating \u0026amp; Cooling Package\u003c\/strong\u003e – Combines a \u003cstrong data-start=\"80\" data-end=\"116\"\u003e60,000 BTU, 96% AFUE gas furnace\u003c\/strong\u003e with a \u003cstrong data-start=\"124\" data-end=\"151\" data-is-only-node=\"\"\u003e2.5 ton air conditioner\u003c\/strong\u003e for dependable \u003cstrong data-start=\"167\" data-end=\"189\"\u003eyear‑round comfort\u003c\/strong\u003e in medium‑sized homes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17z60tl\" data-start=\"216\" data-end=\"367\"\u003e\n\u003cp data-start=\"218\" data-end=\"367\"\u003e\u003cstrong data-start=\"218\" data-end=\"256\"\u003eHigh Heating Efficiency (96% AFUE)\u003c\/strong\u003e – Means most fuel converts to heat, \u003cstrong data-start=\"293\" data-end=\"333\"\u003esignificantly reducing heating costs\u003c\/strong\u003e versus standard‑efficiency units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ko4zqa\" data-start=\"369\" data-end=\"514\"\u003e\n\u003cp data-start=\"371\" data-end=\"514\"\u003e\u003cstrong data-start=\"371\" data-end=\"405\"\u003e14.3 SEER2 Cooling Performance\u003c\/strong\u003e – Meets modern efficiency standards, \u003cstrong data-start=\"443\" data-end=\"484\"\u003elowering energy use and utility bills\u003c\/strong\u003e compared to older AC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o2eiv8\" data-start=\"516\" data-end=\"679\"\u003e\n\u003cp data-start=\"518\" data-end=\"679\"\u003e\u003cstrong data-start=\"518\" data-end=\"552\"\u003eDownflow Furnace Configuration\u003c\/strong\u003e – Ideal for installations in \u003cstrong data-start=\"582\" data-end=\"625\"\u003ebasements or attic‑mounted air handlers\u003c\/strong\u003e, providing installation flexibility for tight spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xokw9d\" data-start=\"681\" data-end=\"812\"\u003e\n\u003cp data-start=\"683\" data-end=\"812\"\u003e\u003cstrong data-start=\"683\" data-end=\"717\"\u003eR‑32 Refrigerant Compatibility\u003c\/strong\u003e – Uses \u003cstrong data-start=\"725\" data-end=\"784\"\u003enext‑generation, lower‑environmental‑impact refrigerant\u003c\/strong\u003e for modern cooling systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"frb8vv\" data-start=\"814\" data-end=\"975\"\u003e\n\u003cp data-start=\"816\" data-end=\"975\"\u003e\u003cstrong data-start=\"816\" data-end=\"849\"\u003eFactory‑Matched System Design\u003c\/strong\u003e – Designed to work together for \u003cstrong data-start=\"882\" data-end=\"933\"\u003eoptimized performance, airflow, and reliability\u003c\/strong\u003e when installed by a qualified technician.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fj7o4y\" data-start=\"977\" data-end=\"1123\"\u003e\n\u003cp data-start=\"979\" data-end=\"1123\"\u003e\u003cstrong data-start=\"979\" data-end=\"1003\"\u003eDurable Construction\u003c\/strong\u003e – Built with \u003cstrong data-start=\"1017\" data-end=\"1073\"\u003ereliable components and Goodman’s proven engineering\u003c\/strong\u003e for long‑term operation with routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1f4uiuf\" data-start=\"1125\" data-end=\"1325\"\u003e\n\u003cp data-start=\"1127\" data-end=\"1325\"\u003e\u003cstrong data-start=\"1127\" data-end=\"1155\"\u003eBalanced Comfort \u0026amp; Value\u003c\/strong\u003e – Excellent choice for homeowners who want \u003cstrong data-start=\"1199\" data-end=\"1274\"\u003eefficient heating, effective cooling, and long‑term energy cost savings\u003c\/strong\u003e without overspending on ultra‑high SEER equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"137\" data-end=\"479\"\u003e\u003cstrong data-start=\"137\" data-end=\"188\"\u003eQ: What’s included in this Goodman HVAC system?\u003c\/strong\u003e\u003cbr data-start=\"188\" data-end=\"191\"\u003eA: This matched system includes a \u003cstrong data-start=\"225\" data-end=\"291\"\u003e2.5 ton 14.3 SEER2 R32 air conditioner condenser (GLXS4BA3010)\u003c\/strong\u003e, a \u003cstrong data-start=\"295\" data-end=\"351\"\u003eCAPTA3026B3 R32‑ready cased evaporator coil with TXV\u003c\/strong\u003e, and a \u003cstrong data-start=\"359\" data-end=\"394\"\u003e96% AFUE 60,000 BTU gas furnace\u003c\/strong\u003e designed for downflow\/horizontal installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"481\" data-end=\"741\"\u003e\u003cstrong data-start=\"481\" data-end=\"527\"\u003eQ: What size home is this system best for?\u003c\/strong\u003e\u003cbr data-start=\"527\" data-end=\"530\"\u003eA: With \u003cstrong data-start=\"538\" data-end=\"580\"\u003e2.5 ton cooling and 60,000 BTU heating\u003c\/strong\u003e, this system fits \u003cstrong data-start=\"599\" data-end=\"646\"\u003emedium to larger homes (~1,500–2,500 sq ft)\u003c\/strong\u003e depending on insulation, local climate, and duct design. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"743\" data-end=\"992\"\u003e\u003cstrong data-start=\"743\" data-end=\"800\"\u003eQ: What does 14.3 SEER2 mean for cooling performance?\u003c\/strong\u003e\u003cbr data-start=\"800\" data-end=\"803\"\u003eA: A \u003cstrong data-start=\"808\" data-end=\"829\"\u003e14.3 SEER2 rating\u003c\/strong\u003e delivers \u003cstrong data-start=\"839\" data-end=\"881\"\u003eefficient seasonal cooling performance\u003c\/strong\u003e, helping reduce electricity costs compared to older, lower‑SEER systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"994\" data-end=\"1217\"\u003e\u003cstrong data-start=\"994\" data-end=\"1045\"\u003eQ: Why is 96% AFUE significant for the furnace?\u003c\/strong\u003e\u003cbr data-start=\"1045\" data-end=\"1048\"\u003eA: \u003cstrong data-start=\"1051\" data-end=\"1063\"\u003e96% AFUE\u003c\/strong\u003e means \u003cstrong data-start=\"1070\" data-end=\"1112\"\u003e96% of the fuel is converted into heat\u003c\/strong\u003e, offering \u003cstrong data-start=\"1123\" data-end=\"1178\"\u003ehigh heating efficiency and lower natural gas costs\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1219\" data-end=\"1427\"\u003e\u003cstrong data-start=\"1219\" data-end=\"1264\"\u003eQ: What refrigerant does this system use?\u003c\/strong\u003e\u003cbr data-start=\"1264\" data-end=\"1267\"\u003eA: This system uses \u003cstrong data-start=\"1287\" data-end=\"1306\"\u003eR32 refrigerant\u003c\/strong\u003e, a more \u003cstrong data-start=\"1315\" data-end=\"1364\"\u003eefficient and environmentally friendly choice\u003c\/strong\u003e than older refrigerants. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1429\" data-end=\"1659\"\u003e\u003cstrong data-start=\"1429\" data-end=\"1491\"\u003eQ: What installation orientation does the furnace support?\u003c\/strong\u003e\u003cbr data-start=\"1491\" data-end=\"1494\"\u003eA: The \u003cstrong data-start=\"1501\" data-end=\"1558\"\u003efurnace supports downflow and horizontal installation\u003c\/strong\u003e, ideal for \u003cstrong data-start=\"1570\" data-end=\"1620\"\u003eattics, crawlspaces, or tight mechanical room\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"272\" data-start=\"143\" data-section-id=\"1ms5j15\"\u003e\n\u003cp data-end=\"272\" data-start=\"145\"\u003e\u003cstrong data-end=\"179\" data-start=\"145\"\u003eReplace Air Filters Regularly:\u003c\/strong\u003e Check every \u003cstrong data-end=\"206\" data-start=\"192\"\u003e1–3 months\u003c\/strong\u003e to maintain airflow and protect both furnace and AC components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"394\" data-start=\"273\" data-section-id=\"18px60r\"\u003e\n\u003cp data-end=\"394\" data-start=\"275\"\u003e\u003cstrong data-end=\"308\" data-start=\"275\"\u003eKeep Vents \u0026amp; Registers Clear:\u003c\/strong\u003e Ensure supply and return vents are unobstructed for consistent heating and cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"520\" data-start=\"395\" data-section-id=\"a8vxk9\"\u003e\n\u003cp data-end=\"520\" data-start=\"397\"\u003e\u003cstrong data-end=\"428\" data-start=\"397\"\u003eClean Outdoor AC Condenser:\u003c\/strong\u003e Rinse coils every \u003cstrong data-end=\"461\" data-start=\"447\"\u003e3–6 months\u003c\/strong\u003e to preserve SEER2 efficiency and prevent debris buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"676\" data-start=\"521\" data-section-id=\"cg0eaw\"\u003e\n\u003cp data-end=\"676\" data-start=\"523\"\u003e\u003cstrong data-end=\"554\" data-start=\"523\"\u003eInspect Furnace Components:\u003c\/strong\u003e Have a professional check burners, heat exchanger, gas pressure, and airflow annually for safe and efficient operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"814\" data-start=\"677\" data-section-id=\"17h9or3\"\u003e\n\u003cp data-end=\"814\" data-start=\"679\"\u003e\u003cstrong data-end=\"720\" data-start=\"679\"\u003eCheck Refrigerant Lines \u0026amp; Insulation:\u003c\/strong\u003e Ensure lines are intact and insulation is in good condition for optimal \u003cstrong data-end=\"811\" data-start=\"793\"\u003eR32 efficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"938\" data-start=\"815\" data-section-id=\"12m7iwu\"\u003e\n\u003cp data-end=\"938\" data-start=\"817\"\u003e\u003cstrong data-end=\"848\" data-start=\"817\"\u003eMaintain Condensate Drains:\u003c\/strong\u003e Keep both furnace and AC drain lines clear to prevent water issues or system shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1094\" data-start=\"939\" data-section-id=\"me0k0n\"\u003e\n\u003cp data-end=\"1094\" data-start=\"941\"\u003e\u003cstrong data-end=\"982\" data-start=\"941\"\u003eSchedule Annual Professional Service:\u003c\/strong\u003e A certified technician should inspect electrical connections, airflow, and overall system performance yearly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1223\" data-start=\"1095\" data-section-id=\"zgt888\"\u003e\n\u003cp data-end=\"1223\" data-start=\"1097\"\u003e\u003cstrong data-end=\"1127\" data-start=\"1097\"\u003eMonitor for Unusual Signs:\u003c\/strong\u003e Strange noises, odors, or inconsistent heating\/cooling require prompt professional attention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533436485706,"sku":"GLXS4BA3010 \/ CAPTA3026B3 \/ GD9S960603BN","price":3612.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/GSXH5cond-CAPTAcoil-90_DownflowFurn_2.webp?v=1776875704","url":"https:\/\/wen0d6-q0.myshopify.com\/es\/products\/goodman-2-5-ton-60-000-btu-96-afue-gas-furnace-and-air-conditioner-system-downflow-14-3-seer2-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}