{"product_id":"goodman-40-000-btu-96-gas-furnace-14-width-upflow-horizontal-two-stage-115v-r32","title":"Goodman - 40,000 BTU 96% Gas Furnace - 14\" Width - Upflow \/ Horizontal - Two Stage - 115V - R32 - GR9T960403AN","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 40,000 BTU 96% Gas Furnace - 14\" Width - Upflow \/ Horizontal - Two Stage - 115V - R32 - GR9T960403AN\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAs a high-efficiency system, the GR9T960403AN Goodman gas furnace features many money saving features. The two-stage, 9-speed furnace uses a superior heat exchanger for better heat transfers to your home. Considered one of the best efficiencies on the market, the GR9T960403AN is a good way to go if you want to lower your gas bill.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThis furnace is ideal to heat a smaller house (depending on climate)\u003c\/li\u003e\n\u003cli\u003e40,000 BTU 96% AFUE natural gas furnace\u003c\/li\u003e\n\u003cli\u003eRequires plastic\/PVC flue venting\u003c\/li\u003e\n\u003cli\u003eComplies with Clean Air Act New Refrigerant Requirements\u003c\/li\u003e\n\u003cli\u003eCan be used in the upflow or horizontal orientation\u003c\/li\u003e\n\u003cli\u003eCan be converted to an LP furnace with an optional conversion kit (sold separately)\u003c\/li\u003e\n\u003cli\u003eInnovative design for electrical efficiency, safety, and lower sound output\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wa1i\"\u003eSKU\u003c\/th\u003e\n\u003cth class=\"tg-cly1\"\u003eGR9T960403AN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e106.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e215225024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eExhaust Flue Requirement\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003ePlastic \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eR-32 Compliant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eProduct Features\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eNew Refrigerant Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eFurnace Efficiency \/ AFUE\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e40,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e9 Speed - ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eEnergy Star\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e115 V. 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e15 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e7.8 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBurner Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003ePropane, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e34.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e28.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GR9T96-GD9T96-Install-Manual.pdf?v=1759999427\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eInstallation Manual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GR9T96_Spec_Sheet.pdf?v=1759999423\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eSpecifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul data-start=\"104\" data-end=\"725\"\u003e\n\u003cli data-section-id=\"vlr0r3\" data-start=\"104\" data-end=\"196\"\u003e\n\u003cp data-start=\"106\" data-end=\"196\"\u003e\u003cstrong data-start=\"106\" data-end=\"126\"\u003eHigh Efficiency:\u003c\/strong\u003e 96% AFUE rating lowers energy bills while delivering reliable heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"j9cdqp\" data-start=\"197\" data-end=\"283\"\u003e\n\u003cp data-start=\"199\" data-end=\"283\"\u003e\u003cstrong data-start=\"199\" data-end=\"223\"\u003eRight-Sized Heating:\u003c\/strong\u003e 40,000 BTU output ideal for small spaces or single rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4gy5fu\" data-start=\"284\" data-end=\"384\"\u003e\n\u003cp data-start=\"286\" data-end=\"384\"\u003e\u003cstrong data-start=\"286\" data-end=\"308\"\u003eTwo-Stage Comfort:\u003c\/strong\u003e Provides quieter, more consistent heat with improved temperature control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ifnfgv\" data-start=\"385\" data-end=\"471\"\u003e\n\u003cp data-start=\"387\" data-end=\"471\"\u003e\u003cstrong data-start=\"387\" data-end=\"413\"\u003eFlexible Installation:\u003c\/strong\u003e 14\" compact width supports upflow or horizontal setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1doow0c\" data-start=\"472\" data-end=\"556\"\u003e\n\u003cp data-start=\"474\" data-end=\"556\"\u003e\u003cstrong data-start=\"474\" data-end=\"495\"\u003eEasy Integration:\u003c\/strong\u003e 115V power supply works with standard residential systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1723bwf\" data-start=\"557\" data-end=\"637\"\u003e\n\u003cp data-start=\"559\" data-end=\"637\"\u003e\u003cstrong data-start=\"559\" data-end=\"578\"\u003eDurable Design:\u003c\/strong\u003e Engineered for long-term reliability in varied climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1y2xne6\" data-start=\"638\" data-end=\"725\"\u003e\n\u003cp data-start=\"640\" data-end=\"725\"\u003e\u003cstrong data-start=\"640\" data-end=\"660\"\u003eQuiet Operation:\u003c\/strong\u003e Optimized for minimal operational noise during heating cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"127\" data-end=\"377\"\u003e\u003cstrong data-start=\"127\" data-end=\"185\"\u003eQ: What size home or space is this furnace suited for?\u003c\/strong\u003e\u003cbr data-start=\"185\" data-end=\"188\"\u003eA: With \u003cstrong data-start=\"196\" data-end=\"229\"\u003e40,000 BTU input and 96% AFUE\u003c\/strong\u003e, it’s ideal for \u003cstrong data-start=\"246\" data-end=\"299\"\u003esmall to medium homes or single‑zone applications\u003c\/strong\u003e, delivering efficient, consistent heat. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"379\" data-end=\"602\"\u003e\u003cstrong data-start=\"379\" data-end=\"421\"\u003eQ: How energy efficient is this model?\u003c\/strong\u003e\u003cbr data-start=\"421\" data-end=\"424\"\u003eA: It has a \u003cstrong data-start=\"436\" data-end=\"455\"\u003e96% AFUE rating\u003c\/strong\u003e, meaning nearly all fuel is converted into heat — \u003cstrong data-start=\"506\" data-end=\"563\"\u003elowering energy costs and boosting winter performance\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"888\"\u003e\u003cstrong data-start=\"604\" data-end=\"648\"\u003eQ: What does “two‑stage” operation mean?\u003c\/strong\u003e\u003cbr data-start=\"648\" data-end=\"651\"\u003eA: The \u003cstrong data-start=\"658\" data-end=\"681\"\u003etwo‑stage gas valve\u003c\/strong\u003e runs at a lower setting during mild weather for quieter, more efficient heat and switches to full power when needed — improving comfort and reducing temperature swings. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"890\" data-end=\"1122\"\u003e\u003cstrong data-start=\"890\" data-end=\"934\"\u003eQ: What blower motor technology is used?\u003c\/strong\u003e\u003cbr data-start=\"934\" data-end=\"937\"\u003eA: Equipped with a \u003cstrong data-start=\"956\" data-end=\"988\"\u003emulti‑speed ECM blower motor\u003c\/strong\u003e, providing \u003cstrong data-start=\"1000\" data-end=\"1049\"\u003esilent airflow and better temperature control\u003c\/strong\u003e than standard single‑speed motors. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1124\" data-end=\"1329\"\u003e\u003cstrong data-start=\"1124\" data-end=\"1176\"\u003eQ: What installation orientations are supported?\u003c\/strong\u003e\u003cbr data-start=\"1176\" data-end=\"1179\"\u003eA: Designed for \u003cstrong data-start=\"1195\" data-end=\"1228\"\u003eupflow or horizontal mounting\u003c\/strong\u003e, offering flexible placement in attics, basements, or closets. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1331\" data-end=\"1521\"\u003e\u003cstrong data-start=\"1331\" data-end=\"1370\"\u003eQ: What fuel types does it support?\u003c\/strong\u003e\u003cbr data-start=\"1370\" data-end=\"1373\"\u003eA: Factory‑configured for \u003cstrong data-start=\"1399\" data-end=\"1414\"\u003enatural gas\u003c\/strong\u003e and \u003cstrong data-start=\"1419\" data-end=\"1450\"\u003econvertible to propane (LP)\u003c\/strong\u003e with an optional conversion kit. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1523\" data-end=\"1693\"\u003e\u003cstrong data-start=\"1523\" data-end=\"1559\"\u003eQ: What venting does it require?\u003c\/strong\u003e\u003cbr data-start=\"1559\" data-end=\"1562\"\u003eA: As a high‑efficiency condensing furnace, it uses \u003cstrong data-start=\"1614\" data-end=\"1637\"\u003eplastic\/PVC venting\u003c\/strong\u003e for safe exhaust. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1695\" data-end=\"1866\"\u003e\u003cstrong data-start=\"1695\" data-end=\"1744\"\u003eQ: What electrical requirements does it have?\u003c\/strong\u003e\u003cbr data-start=\"1744\" data-end=\"1747\"\u003eA: Operates on \u003cstrong data-start=\"1762\" data-end=\"1790\"\u003e115 V single‑phase power\u003c\/strong\u003e, common for residential HVAC systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1868\" data-end=\"2118\"\u003e\u003cstrong data-start=\"1868\" data-end=\"1925\"\u003eQ: What durability and service features are included?\u003c\/strong\u003e\u003cbr data-start=\"1925\" data-end=\"1928\"\u003eA: Includes a \u003cstrong data-start=\"1942\" data-end=\"2039\"\u003eself‑diagnostic control board, silicon nitride igniter, and color‑coded low‑voltage terminals\u003c\/strong\u003e for easier installation and maintenance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cdiv class=\"flex flex-col text-sm\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:b168e384-d1df-4ed6-9474-98c62e7eeec4-19\" data-testid=\"conversation-turn-40\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"c20e13d8-f6c5-4170-bf9a-9a72815d917b\" dir=\"auto\" data-message-model-slug=\"gpt-5-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cul data-start=\"106\" data-end=\"948\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"19v370a\" data-start=\"106\" data-end=\"186\"\u003e\n\u003cp data-start=\"108\" data-end=\"186\"\u003e\u003cstrong data-start=\"108\" data-end=\"148\"\u003eReplace air filters every 1–3 months\u003c\/strong\u003e to maintain airflow and efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"120yn51\" data-start=\"187\" data-end=\"268\"\u003e\n\u003cp data-start=\"189\" data-end=\"268\"\u003eKeep \u003cstrong data-start=\"194\" data-end=\"227\"\u003esupply and return vents clear\u003c\/strong\u003e to ensure proper heating distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iif3ij\" data-start=\"269\" data-end=\"346\"\u003e\n\u003cp data-start=\"271\" data-end=\"346\"\u003eMaintain \u003cstrong data-start=\"280\" data-end=\"324\"\u003e2–3 feet of clearance around the furnace\u003c\/strong\u003e for safe operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"119o52v\" data-start=\"347\" data-end=\"416\"\u003e\n\u003cp data-start=\"349\" data-end=\"416\"\u003eInspect the \u003cstrong data-start=\"361\" data-end=\"386\"\u003econdensate drain line\u003c\/strong\u003e regularly to prevent clogs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16qgz4t\" data-start=\"417\" data-end=\"507\"\u003e\n\u003cp data-start=\"419\" data-end=\"507\"\u003e\u003cstrong data-start=\"419\" data-end=\"462\"\u003eCheck thermostat settings and operation\u003c\/strong\u003e to ensure smooth two-stage heating cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tmmhoi\" data-start=\"508\" data-end=\"574\"\u003e\n\u003cp data-start=\"510\" data-end=\"574\"\u003eExamine \u003cstrong data-start=\"518\" data-end=\"548\"\u003event pipes and connections\u003c\/strong\u003e for leaks or blockages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d9a1x0\" data-start=\"575\" data-end=\"672\"\u003e\n\u003cp data-start=\"577\" data-end=\"672\"\u003eListen for \u003cstrong data-start=\"588\" data-end=\"606\"\u003eunusual noises\u003c\/strong\u003e like rattling or humming, which may indicate mechanical issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xqr6xe\" data-start=\"673\" data-end=\"751\"\u003e\n\u003cp data-start=\"675\" data-end=\"751\"\u003eClean \u003cstrong data-start=\"681\" data-end=\"725\"\u003eblower compartment and internal surfaces\u003c\/strong\u003e to reduce dust buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10b2gmo\" data-start=\"752\" data-end=\"834\"\u003e\n\u003cp data-start=\"754\" data-end=\"834\"\u003eTest \u003cstrong data-start=\"759\" data-end=\"788\"\u003ecarbon monoxide detectors\u003c\/strong\u003e to ensure safe operation with gas furnaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j76b0c\" data-start=\"835\" data-end=\"948\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"837\" data-end=\"948\" data-is-last-node=\"\"\u003eSchedule \u003cstrong data-start=\"846\" data-end=\"881\"\u003eannual professional maintenance\u003c\/strong\u003e to inspect burners, heat exchanger, gas connections, and controls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533441007690,"sku":"GR9T960403AN","price":1407.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/90_upflow_front-800x800_1_16_1f774b77-3caf-46af-a2ca-f45289d3f946.webp?v=1776875948","url":"https:\/\/wen0d6-q0.myshopify.com\/es\/products\/goodman-40-000-btu-96-gas-furnace-14-width-upflow-horizontal-two-stage-115v-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}