{"product_id":"goodman-5-ton-60-000-btu-multi-positional-air-conditioner-split-system-13-8-seer2-r32","title":"Goodman - 5 Ton\/60,000 BTU - Multi-Positional - Air Conditioner Split System - 13.8 SEER2 - R32 - GLXS3BN6010","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 5 Ton\/60,000 BTU - Multi-Positional - Air Conditioner Split System - 13.8 SEER2 - R32 - GLXS3BN6010 \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eA Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman air conditioner split system is the perfect choice for all of your cooling needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal size to cover a medium-sized house\u003c\/li\u003e\n\u003cli\u003e5 ton, 13.4 SEER2 AC-only condenser\u003c\/li\u003e\n\u003cli\u003eR32: Complies with Clean Air Act New Refrigerant Requirements\u003c\/li\u003e\n\u003cli\u003eLow sound output\u003c\/li\u003e\n\u003cli\u003eFully charged for up to 15' of line set\u003c\/li\u003e\n\u003cli\u003eFactory-installed filter drier\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAir Handler\u003c\/li\u003e\n\u003cli\u003e5 ton air handler\u003c\/li\u003e\n\u003cli\u003eElectric heat compatible\u003c\/li\u003e\n\u003cli\u003eOptimized for use with R-32 refrigerant\u003c\/li\u003e\n\u003cli\u003eMulti-speed, direct drive ECM blower motor\u003c\/li\u003e\n\u003cli\u003eMulti-positional (upflow, downflow, or horizontal)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" class=\"tg-wa1i\"\u003e5 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGLXS3BN6010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e244.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eReplaces\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGSX130601 and GSXN3N6010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e60,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Speed PSC Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHorsepower\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1\/4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSEER2\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e13.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eScroll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e208 \/ 230 V. 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e50 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e31.1 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e39 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e35 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e35 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman_Condenser_Install_Manual_v2023_af457533-e299-4010-a608-3f97394733ee.pdf?v=1727168675\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003eGLXS3B \u003c\/span\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-GLXS3B-specsheet_246499af-feef-40bc-855c-7fd04a53997f.pdf?v=1727168689\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003eGLXS3B \u003c\/span\u003eSpecifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/AMST_Install_Manual_2ecccd50-6ef5-45ce-aaae-c506fd4e6884.pdf?v=1727168684\" target=\"_blank\"\u003e\u003cstrong\u003eAMST Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-AirHandlerR32-specsheet_46186ad2-0e40-460d-ac30-f43168585037.pdf?v=1727168673\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong style=\"color: rgb(43, 0, 255);\"\u003eAMST Specifications Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"tebfq6\" data-start=\"27\" data-end=\"221\"\u003e\n\u003cp data-start=\"29\" data-end=\"221\"\u003e\u003cstrong data-start=\"29\" data-end=\"68\"\u003e5 Ton \/ 60,000 BTU Cooling Capacity\u003c\/strong\u003e – Designed for \u003cstrong data-start=\"84\" data-end=\"123\"\u003elarger homes and high‑demand spaces\u003c\/strong\u003e, delivering steady cooling performance throughout summer. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kmzpjz\" data-start=\"222\" data-end=\"442\"\u003e\n\u003cp data-start=\"224\" data-end=\"442\"\u003e\u003cstrong data-start=\"224\" data-end=\"271\"\u003e13.8 SEER2 Efficiency with R‑32 Refrigerant\u003c\/strong\u003e – Meets modern efficiency standards while using \u003cstrong data-start=\"320\" data-end=\"353\"\u003eeco‑friendly R‑32 refrigerant\u003c\/strong\u003e, balancing performance and environmental impact. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uolf6o\" data-start=\"443\" data-end=\"637\"\u003e\n\u003cp data-start=\"445\" data-end=\"637\"\u003e\u003cstrong data-start=\"445\" data-end=\"479\"\u003eSingle‑Stage Scroll Compressor\u003c\/strong\u003e – Simple, \u003cstrong data-start=\"490\" data-end=\"512\"\u003ereliable operation\u003c\/strong\u003e with consistent cooling output and lower initial cost compared to multi‑stage units. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1m4ubyz\" data-start=\"638\" data-end=\"831\"\u003e\n\u003cp data-start=\"640\" data-end=\"831\"\u003e\u003cstrong data-start=\"640\" data-end=\"672\"\u003eMulti‑Positional Air Handler\u003c\/strong\u003e – Install in \u003cstrong data-start=\"686\" data-end=\"734\"\u003eupflow, downflow, or horizontal orientations\u003c\/strong\u003e, ideal for varied duct layouts and tight utility spaces. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zf57vw\" data-start=\"832\" data-end=\"1045\"\u003e\n\u003cp data-start=\"834\" data-end=\"1045\"\u003e\u003cstrong data-start=\"834\" data-end=\"856\"\u003eECM Motor with TXV\u003c\/strong\u003e – Enhanced blower efficiency and internal thermal expansion valve help \u003cstrong data-start=\"928\" data-end=\"972\"\u003eoptimize airflow and refrigerant control\u003c\/strong\u003e for steadier system performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zh4jf2\" data-start=\"1046\" data-end=\"1260\"\u003e\n\u003cp data-start=\"1048\" data-end=\"1260\"\u003e\u003cstrong data-start=\"1048\" data-end=\"1099\"\u003eFactory‑Installed Filter Drier \u0026amp; Service Valves\u003c\/strong\u003e – Simplifies maintenance and improves \u003cstrong data-start=\"1138\" data-end=\"1163\"\u003elong‑term reliability\u003c\/strong\u003e by protecting the system from moisture and contaminants. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ylkflz\" data-start=\"1261\" data-end=\"1422\"\u003e\n\u003cp data-start=\"1263\" data-end=\"1422\"\u003e\u003cstrong data-start=\"1263\" data-end=\"1287\"\u003eDurable Construction\u003c\/strong\u003e – Powder‑coat finish and robust coil guard resist outdoor wear and \u003cstrong data-start=\"1355\" data-end=\"1381\"\u003eextend system lifespan\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16lxikv\" data-start=\"1423\" data-end=\"1597\"\u003e\n\u003cp data-start=\"1425\" data-end=\"1597\"\u003e\u003cstrong data-start=\"1425\" data-end=\"1453\"\u003eBroad HVAC Compatibility\u003c\/strong\u003e – Works with compatible indoor coils or air handlers for \u003cstrong data-start=\"1511\" data-end=\"1556\"\u003eflexible replacement or new installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"126\" data-end=\"411\"\u003e\u003cstrong data-start=\"126\" data-end=\"173\"\u003eQ: What is this Goodman GLXS3BN6010 system?\u003c\/strong\u003e\u003cbr data-start=\"173\" data-end=\"176\"\u003eA: It’s a \u003cstrong data-start=\"186\" data-end=\"307\"\u003e5‑ton (60,000 BTU) R32‑refrigerant split‑system air conditioner condenser and compatible multi‑positional indoor unit\u003c\/strong\u003e, built for large residential or light commercial cooling needs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"413\" data-end=\"717\"\u003e\u003cstrong data-start=\"413\" data-end=\"466\"\u003eQ: What does a 13.8 SEER2 efficiency rating mean?\u003c\/strong\u003e\u003cbr data-start=\"466\" data-end=\"469\"\u003eA: \u003cstrong data-start=\"472\" data-end=\"486\"\u003e13.8 SEER2\u003c\/strong\u003e (often listed as \u003cstrong data-start=\"504\" data-end=\"518\"\u003e13.4 SEER2\u003c\/strong\u003e) reflects \u003cstrong data-start=\"529\" data-end=\"559\"\u003eseasonal energy efficiency\u003c\/strong\u003e — it’s designed to \u003cstrong data-start=\"579\" data-end=\"608\"\u003ehelp reduce cooling costs\u003c\/strong\u003e compared to older, lower SEER units while meeting current standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"719\" data-end=\"964\"\u003e\u003cstrong data-start=\"719\" data-end=\"755\"\u003eQ: What refrigerant does it use?\u003c\/strong\u003e\u003cbr data-start=\"755\" data-end=\"758\"\u003eA: This system uses \u003cstrong data-start=\"778\" data-end=\"797\"\u003eR32 refrigerant\u003c\/strong\u003e, a more \u003cstrong data-start=\"806\" data-end=\"858\"\u003eefficient and environmentally responsible choice\u003c\/strong\u003e with lower global warming potential than many older refrigerants. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"966\" data-end=\"1173\"\u003e\u003cstrong data-start=\"966\" data-end=\"1010\"\u003eQ: What kind of compressor does it have?\u003c\/strong\u003e\u003cbr data-start=\"1010\" data-end=\"1013\"\u003eA: The outdoor condenser features a \u003cstrong data-start=\"1049\" data-end=\"1083\"\u003esingle‑stage scroll compressor\u003c\/strong\u003e for \u003cstrong data-start=\"1088\" data-end=\"1132\"\u003ereliable, consistent cooling performance\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1175\" data-end=\"1440\"\u003e\u003cstrong data-start=\"1175\" data-end=\"1222\"\u003eQ: What is “multi‑positional” installation?\u003c\/strong\u003e\u003cbr data-start=\"1222\" data-end=\"1225\"\u003eA: \u003cstrong data-start=\"1228\" data-end=\"1255\"\u003eMulti‑positional design\u003c\/strong\u003e means the indoor air handler can be installed \u003cstrong data-start=\"1302\" data-end=\"1339\"\u003eupflow, downflow, or horizontally\u003c\/strong\u003e, offering flexibility for different duct layouts and spaces. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1442\" data-end=\"1609\"\u003e\u003cstrong data-start=\"1442\" data-end=\"1470\"\u003eQ: How loud is the unit?\u003c\/strong\u003e\u003cbr data-start=\"1470\" data-end=\"1473\"\u003eA: Typical operating sound levels are around \u003cstrong data-start=\"1518\" data-end=\"1528\"\u003e74 dBA\u003c\/strong\u003e, which is average for a 5‑ton condenser. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1611\" data-end=\"1843\"\u003e\u003cstrong data-start=\"1611\" data-end=\"1660\"\u003eQ: What size spaces is a 5‑ton AC suited for?\u003c\/strong\u003e\u003cbr data-start=\"1660\" data-end=\"1663\"\u003eA: A \u003cstrong data-start=\"1668\" data-end=\"1690\"\u003e5 ton (60,000 BTU)\u003c\/strong\u003e capacity is ideal for \u003cstrong data-start=\"1713\" data-end=\"1769\"\u003elarge homes, bigger apartments, or commercial spaces\u003c\/strong\u003e that require high cooling output.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1lqqdu\" data-start=\"132\" data-end=\"280\"\u003e\n\u003cp data-start=\"134\" data-end=\"280\"\u003e\u003cstrong data-start=\"134\" data-end=\"162\"\u003eKeep Outdoor Unit Clear:\u003c\/strong\u003e Maintain \u003cstrong data-start=\"172\" data-end=\"198\"\u003e24 inches of clearance\u003c\/strong\u003e around the condenser; remove leaves, dirt, and debris to ensure proper airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1k7czzm\" data-start=\"281\" data-end=\"393\"\u003e\n\u003cp data-start=\"283\" data-end=\"393\"\u003e\u003cstrong data-start=\"283\" data-end=\"309\"\u003eClean Condenser Coils:\u003c\/strong\u003e Rinse every \u003cstrong data-start=\"322\" data-end=\"336\"\u003e3–6 months\u003c\/strong\u003e to prevent dirt buildup that reduces SEER2 efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ktdqys\" data-start=\"394\" data-end=\"509\"\u003e\n\u003cp data-start=\"396\" data-end=\"509\"\u003e\u003cstrong data-start=\"396\" data-end=\"427\"\u003eReplace Indoor Air Filters:\u003c\/strong\u003e Change filters every \u003cstrong data-start=\"449\" data-end=\"463\"\u003e1–3 months\u003c\/strong\u003e to protect the system and maintain airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ggody5\" data-start=\"510\" data-end=\"644\"\u003e\n\u003cp data-start=\"512\" data-end=\"644\"\u003e\u003cstrong data-start=\"512\" data-end=\"555\"\u003eInspect Refrigerant Lines \u0026amp; Insulation:\u003c\/strong\u003e Ensure lines are intact and insulation is not damaged for optimal \u003cstrong data-start=\"622\" data-end=\"641\"\u003eR32 performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tal7au\" data-start=\"645\" data-end=\"752\"\u003e\n\u003cp data-start=\"647\" data-end=\"752\"\u003e\u003cstrong data-start=\"647\" data-end=\"674\"\u003eCheck Condensate Drain:\u003c\/strong\u003e Keep the drain line clear to prevent water buildup or system interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k4cbhu\" data-start=\"753\" data-end=\"925\"\u003e\n\u003cp data-start=\"755\" data-end=\"925\"\u003e\u003cstrong data-start=\"755\" data-end=\"796\"\u003eSchedule Annual Professional Service:\u003c\/strong\u003e Technicians should inspect electrical connections, refrigerant levels, fan motor, and overall split system performance yearly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ot3fno\" data-start=\"926\" data-end=\"1052\"\u003e\n\u003cp data-start=\"928\" data-end=\"1052\"\u003e\u003cstrong data-start=\"928\" data-end=\"959\"\u003eMonitor System Performance:\u003c\/strong\u003e Unusual noises, weak cooling, or higher energy bills indicate the need for prompt service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533436878922,"sku":"GLXS3BN6010 \/ AMST60DU1300","price":3668.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/goodman-split-gsxh5-amst_46_76f5198a-d7b2-4948-ad43-dd78f3eb4247.webp?v=1776875726","url":"https:\/\/wen0d6-q0.myshopify.com\/es\/products\/goodman-5-ton-60-000-btu-multi-positional-air-conditioner-split-system-13-8-seer2-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}