{"product_id":"mitsubishi-17kw-electric-heater-module-large-cabinet-pva","title":"Mitsubishi 17kW Electric Heater Module - Large Cabinet, PVA - EH17-MPAS-L","description":"\u003cdiv class=\"product_details\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv class=\"product_details\"\u003e\n\u003ch2\u003eMitsubishi 17kW Electric Heater Module - Large Cabinet, PVA - EH17-MPAS-L\u003c\/h2\u003e\n\u003cp\u003eMitsubishi electric back-up heater module for P-Series PVA multi-position air handlers\u003c\/p\u003e\n\u003cp\u003eThis module is necessary for the systems installed in cold regions \u003c\/p\u003e\nUnit Type: Electric Back-up Heater ModuleProduct Line: P-Series PVACompatible Air Handlers: PVA-A42AARequired Accessory\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e: \u003ca style=\"color: rgb(0, 0, 0);\" title=\"SPTB1 Separate Power Terminal Block\" href=\"https:\/\/gotductless.com\/products\/mitsubishi-separate-terminal-power-block-sptb1\" target=\"_blank\"\u003eSPTB1\u003c\/a\u003e - Se\u003c\/span\u003eparate Terminal Power Block\n\u003ch5 class=\"p1\"\u003eIncludes\u003c\/h5\u003e\n\u003clabel\u003eUnit EH17-MPAS-L\u003c\/label\u003e\n\u003ch5 class=\"p1\"\u003eSpecifications\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-oevy{background-color:#ffffff;border-color:#000000;color:#000000;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003cdiv class=\"product_details\"\u003e\n\u003cdiv class=\"product_details\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-oevy\"\u003eVoltage\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003e208\/240 V, 1‑Phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eHeater Power (kW)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e13.2 \/ 17.5 (208\/240 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eHeater Amps (Circuits 1 \u0026amp; 2)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e31.6 \/ 36.5 A (208\/240 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eStages kW (1st + 2nd)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e8.75 + 8.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eFactory Installed Breaker (Circuit 1\/2)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e60 A \/ 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e25\" × 21‑1\/4\" × 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5 class=\"grid__item medium-up--one-half\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1ayn11c\" data-start=\"27\" data-end=\"350\"\u003e\n\u003cp data-start=\"29\" data-end=\"350\"\u003e\u003cstrong data-start=\"29\" data-end=\"82\"\u003ePowerful auxiliary heating when temperatures drop\u003c\/strong\u003e\u003cbr data-start=\"82\" data-end=\"85\"\u003eThe \u003cstrong data-start=\"91\" data-end=\"132\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eMitsubishi EH17‑MPAS‑L Electric Heater Module\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e provides up to \u003cstrong data-start=\"148\" data-end=\"194\" data-is-only-node=\"\"\u003e17.5 kW of electric heat (13.2 kW at 208V)\u003c\/strong\u003e, delivering strong supplemental heating when a heat pump alone cannot maintain indoor comfort in very cold weather. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"61ee0u\" data-start=\"352\" data-end=\"643\"\u003e\n\u003cp data-start=\"354\" data-end=\"643\"\u003e\u003cstrong data-start=\"354\" data-end=\"400\"\u003eTwo-stage heating for balanced performance\u003c\/strong\u003e\u003cbr data-start=\"400\" data-end=\"403\"\u003eThe module operates with \u003cstrong data-start=\"430\" data-end=\"473\"\u003etwo heating stages (≈8.75 kW + 8.75 kW)\u003c\/strong\u003e, allowing the system to increase heat output gradually and maintain stable indoor temperatures without unnecessary energy spikes. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pqzktf\" data-start=\"645\" data-end=\"949\"\u003e\n\u003cp data-start=\"647\" data-end=\"949\"\u003e\u003cstrong data-start=\"647\" data-end=\"702\"\u003eDesigned for Mitsubishi multi-position air handlers\u003c\/strong\u003e\u003cbr data-start=\"702\" data-end=\"705\"\u003eEngineered specifically for \u003cstrong data-start=\"735\" data-end=\"777\"\u003ePVA-series multi-position air handlers\u003c\/strong\u003e, the heater integrates seamlessly with compatible Mitsubishi ducted systems used in residential and light-commercial installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3qtbk7\" data-start=\"951\" data-end=\"1220\"\u003e\n\u003cp data-start=\"953\" data-end=\"1220\"\u003e\u003cstrong data-start=\"953\" data-end=\"1008\"\u003eDirect-mount installation for cleaner system design\u003c\/strong\u003e\u003cbr data-start=\"1008\" data-end=\"1011\"\u003eThe heater module \u003cstrong data-start=\"1031\" data-end=\"1098\"\u003emounts directly to the air outlet connection of the air handler\u003c\/strong\u003e, simplifying installation and maintaining proper airflow through the duct system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r0aebl\" data-start=\"1222\" data-end=\"1463\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1463\"\u003e\u003cstrong data-start=\"1224\" data-end=\"1266\"\u003eReliable backup heat for cold climates\u003c\/strong\u003e\u003cbr data-start=\"1266\" data-end=\"1269\"\u003eElectric heater modules like this are commonly used as \u003cstrong data-start=\"1326\" data-end=\"1357\"\u003eauxiliary or emergency heat\u003c\/strong\u003e, automatically activating when outdoor temperatures fall below the heat pump’s optimal operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q4nr98\" data-start=\"1465\" data-end=\"1720\"\u003e\n\u003cp data-start=\"1467\" data-end=\"1720\"\u003e\u003cstrong data-start=\"1467\" data-end=\"1500\"\u003eRobust electrical performance\u003c\/strong\u003e\u003cbr data-start=\"1500\" data-end=\"1503\"\u003eOperating at \u003cstrong data-start=\"1518\" data-end=\"1557\"\u003e208\/240V and roughly 31.6–36.5 amps\u003c\/strong\u003e, the heater provides consistent heating capacity for larger ducted systems that require additional winter heating support. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xbdglr\" data-start=\"1722\" data-end=\"1952\"\u003e\n\u003cp data-start=\"1724\" data-end=\"1952\"\u003e\u003cstrong data-start=\"1724\" data-end=\"1754\"\u003eBuilt-in safety components\u003c\/strong\u003e\u003cbr data-start=\"1754\" data-end=\"1757\"\u003eIncludes \u003cstrong data-start=\"1768\" data-end=\"1823\"\u003ethermal limit cutoffs, relays, and protective fuses\u003c\/strong\u003e to safeguard the system and ensure safe operation during high-output heating conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1h02tty\" data-start=\"1954\" data-end=\"2169\"\u003e\n\u003cp data-start=\"1956\" data-end=\"2169\"\u003e\u003cstrong data-start=\"1956\" data-end=\"2008\"\u003eLarge cabinet design for higher capacity systems\u003c\/strong\u003e\u003cbr data-start=\"2008\" data-end=\"2011\"\u003eThe \u003cstrong data-start=\"2017\" data-end=\"2048\"\u003elarge cabinet configuration\u003c\/strong\u003e is designed for larger air handlers and higher heating loads, making it ideal for whole-home ducted heat pump systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"grid__item medium-up--one-half\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"93\" data-end=\"391\"\u003e\u003cstrong data-start=\"93\" data-end=\"158\"\u003eQ: What is the Mitsubishi EH17-MPAS-L electric heater module?\u003c\/strong\u003e\u003cbr data-start=\"158\" data-end=\"161\"\u003eA: The EH17-MPAS-L is an \u003cstrong data-start=\"186\" data-end=\"222\"\u003eoptional 17 kW electric heat kit\u003c\/strong\u003e designed for Mitsubishi \u003cstrong data-start=\"247\" data-end=\"282\"\u003ePVA multi-position air handlers\u003c\/strong\u003e, providing auxiliary or backup heating for ducted heat pump systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"393\" data-end=\"672\"\u003e\u003cstrong data-start=\"393\" data-end=\"448\"\u003eQ: What is the heating capacity of the EH17-MPAS-L?\u003c\/strong\u003e\u003cbr data-start=\"448\" data-end=\"451\"\u003eA: This heater module provides \u003cstrong data-start=\"482\" data-end=\"526\"\u003eup to 17.5 kW of electric heating (240V)\u003c\/strong\u003e or \u003cstrong data-start=\"530\" data-end=\"549\"\u003e13.2 kW at 208V\u003c\/strong\u003e, delivering strong supplemental heat when the heat pump needs additional capacity. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"674\" data-end=\"928\"\u003e\u003cstrong data-start=\"674\" data-end=\"734\"\u003eQ: How many heating stages does this heater module have?\u003c\/strong\u003e\u003cbr data-start=\"734\" data-end=\"737\"\u003eA: The EH17-MPAS-L features \u003cstrong data-start=\"765\" data-end=\"795\"\u003etwo-stage electric heating\u003c\/strong\u003e, typically split into \u003cstrong data-start=\"818\" data-end=\"846\"\u003e8.75 kW + 8.75 kW stages\u003c\/strong\u003e, improving efficiency and system control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"930\" data-end=\"1182\"\u003e\u003cstrong data-start=\"930\" data-end=\"985\"\u003eQ: What systems is the EH17-MPAS-L compatible with?\u003c\/strong\u003e\u003cbr data-start=\"985\" data-end=\"988\"\u003eA: It is designed for \u003cstrong data-start=\"1010\" data-end=\"1056\"\u003eMitsubishi PVA multi-position air handlers\u003c\/strong\u003e and compatible ducted systems such as \u003cstrong data-start=\"1095\" data-end=\"1141\"\u003ePVA-A42AA4\/A7 and select PVFY air handlers\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1184\" data-end=\"1415\"\u003e\u003cstrong data-start=\"1184\" data-end=\"1233\"\u003eQ: What voltage does the EH17-MPAS-L require?\u003c\/strong\u003e\u003cbr data-start=\"1233\" data-end=\"1236\"\u003eA: The heater module operates on \u003cstrong data-start=\"1269\" data-end=\"1300\"\u003e208\/240V single-phase power\u003c\/strong\u003e and requires a dedicated electrical supply separate from the outdoor unit. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1417\" data-end=\"1690\"\u003e\u003cstrong data-start=\"1417\" data-end=\"1468\"\u003eQ: How is the electric heater module installed?\u003c\/strong\u003e\u003cbr data-start=\"1468\" data-end=\"1471\"\u003eA: The EH17-MPAS-L \u003cstrong data-start=\"1490\" data-end=\"1557\"\u003emounts directly to the air outlet connection on the air handler\u003c\/strong\u003e, integrating with the ducted system to deliver heated airflow through the existing ductwork. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1692\" data-end=\"1913\"\u003e\u003cstrong data-start=\"1692\" data-end=\"1756\"\u003eQ: What are the dimensions of the EH17-MPAS-L heater module?\u003c\/strong\u003e\u003cbr data-start=\"1756\" data-end=\"1759\"\u003eA: The unit measures approximately \u003cstrong data-start=\"1794\" data-end=\"1824\"\u003e25″ W × 22-13\/16″ D × 6″ H\u003c\/strong\u003e, designed to fit large-cabinet PVA air handlers. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1915\" data-end=\"2205\"\u003e\u003cstrong data-start=\"1915\" data-end=\"1973\"\u003eQ: Why add an electric heat kit to a heat pump system?\u003c\/strong\u003e\u003cbr data-start=\"1973\" data-end=\"1976\"\u003eA: Electric heater modules provide \u003cstrong data-start=\"2011\" data-end=\"2128\"\u003eauxiliary heating during extreme cold conditions, defrost cycles, or when additional heating capacity is required\u003c\/strong\u003e, ensuring consistent indoor comfort. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2207\" data-end=\"2466\"\u003e\u003cstrong data-start=\"2207\" data-end=\"2262\"\u003eQ: Does this heater require additional accessories?\u003c\/strong\u003e\u003cbr data-start=\"2262\" data-end=\"2265\"\u003eA: Yes. Installations typically require the \u003cstrong data-start=\"2309\" data-end=\"2348\"\u003eSPTB1 Separate Power Terminal Block\u003c\/strong\u003e, which allows the heater to receive power from a dedicated electrical source.\u003c\/p\u003e\n\u003ch5 class=\"grid__item medium-up--one-half\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"2vnc14\" data-start=\"280\" data-end=\"562\"\u003e\n\u003cp data-start=\"282\" data-end=\"562\"\u003e\u003cstrong data-start=\"282\" data-end=\"317\"\u003eInspect Electrical Connections:\u003c\/strong\u003e Periodically check wiring, relays, and breakers for signs of wear or loose connections. Electric heat kits operate on \u003cstrong data-start=\"436\" data-end=\"454\"\u003e208\/240V power\u003c\/strong\u003e, so secure electrical connections are essential for safe operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tpi9r8\" data-start=\"563\" data-end=\"732\"\u003e\n\u003cp data-start=\"565\" data-end=\"732\"\u003e\u003cstrong data-start=\"565\" data-end=\"593\"\u003eKeep Airflow Path Clear:\u003c\/strong\u003e Ensure supply ducts and air handler filters remain clean to maintain proper airflow across the heating elements and prevent overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j1r0an\" data-start=\"733\" data-end=\"950\"\u003e\n\u003cp data-start=\"735\" data-end=\"950\"\u003e\u003cstrong data-start=\"735\" data-end=\"772\"\u003eCheck Safety Limits and Breakers:\u003c\/strong\u003e The heater module includes \u003cstrong data-start=\"800\" data-end=\"846\"\u003ethermal limit cutoffs and circuit breakers\u003c\/strong\u003e designed to prevent overheating—inspect during routine service. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6ipexj\" data-start=\"951\" data-end=\"1119\"\u003e\n\u003cp data-start=\"953\" data-end=\"1119\"\u003e\u003cstrong data-start=\"953\" data-end=\"995\"\u003eMaintain Clean Air Handler Components:\u003c\/strong\u003e Dust buildup on blower components or coils can reduce airflow, causing the heater to work harder and lowering efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w20zv8\" data-start=\"1120\" data-end=\"1308\"\u003e\n\u003cp data-start=\"1122\" data-end=\"1308\"\u003e\u003cstrong data-start=\"1122\" data-end=\"1153\"\u003eVerify Proper Power Supply:\u003c\/strong\u003e The electric heater requires a \u003cstrong data-start=\"1185\" data-end=\"1210\"\u003eseparate power supply\u003c\/strong\u003e and should not be powered directly from the outdoor unit. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bp8xrs\" data-start=\"1309\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1311\" data-end=\"1495\"\u003e\u003cstrong data-start=\"1311\" data-end=\"1352\"\u003eSchedule Annual Professional Service:\u003c\/strong\u003e A licensed HVAC technician should inspect heating elements, electrical relays, and safety controls annually to ensure reliable backup heating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":43533461782602,"sku":"EH17-MPAS-L","price":825.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/Heater1_2e71c23b-73f6-405a-872a-5bcdd82d3df0.jpg?v=1776877193","url":"https:\/\/wen0d6-q0.myshopify.com\/es\/products\/mitsubishi-17kw-electric-heater-module-large-cabinet-pva","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}