{"product_id":"mitsubishi-20-000-btu-mxz-2c20na-two-zone-heat-pump-unit","title":"MXZ-2C20NA - Mitsubishi 20,000 BTU 2-Zone Heat Pump Unit - R410A - MXZ-2C20NA","description":"\u003cdiv class=\"product_details\"\u003e\n\u003cdiv class=\"grid__item medium-up--one-half\"\u003e\n\u003ch2\u003eMXZ-2C20NA - Mitsubishi 20,000 BTU 2-Zone Heat Pump Unit - R410A - MXZ-2C20NA\u003c\/h2\u003e\n\u003cp\u003eThe Mitsubishi 20,000 BTU dual multi-zone outdoor heat pump (MXZ-2C20NA) is an extremely efficient heating and cooling option that can handle two zones.\u003c\/p\u003e\n\u003cp\u003eMitsubishi's current 20,000 BTU outdoor heat pump model is the MXZ-2C20NA3-U1. This specific outdoor unit allows you to connect a wide variety of indoor units that can range up to 15,000 BTU. The MXZ-2C20NA is part of Mitsubishi's M-Series, catering to residential applications.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cdiv class=\"product_details\"\u003e\n\u003col\u003e\n\u003cli\u003eLine Set - When hooking up indoor units to the MXZ-5C42NA, you'll need refrigerant lines. There can be three different combinations for this outdoor unit\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e: \u003ca style=\"color: rgb(0, 0, 0);\" title='1\/4\" x 3\/8\" Line-set Kit' href=\"https:\/\/gotductless.com\/products\/1-4-3-8-install-package-kit\" target=\"_blank\"\u003e1\/4\" \u0026amp; 3\/8\" \u003c\/a\u003efor 6,000-12,000 BTU units, \u003ca style=\"color: rgb(0, 0, 0);\" title='1\/4\" \u0026amp; 1\/2\" Line-set' href=\"https:\/\/gotductless.com\/products\/1-4-1-2-installation-package-kit\" target=\"_blank\"\u003e1\/4\" \u0026amp; 1\/2'\u003c\/a\u003e for 15,000-18,000 BTU units, and \u003ca style=\"color: rgb(0, 0, 0);\" title='3\/8\" x 5\/8\" line-set kit' href=\"https:\/\/gotductless.com\/products\/3-8-5-8-installation-package-kit\" target=\"_blank\"\u003e3\/8\" \u0026amp; 5\/8\" \u003c\/a\u003efor 24,000 BTU units. Our line-sets kits come in diff\u003c\/span\u003eerent lengths; however, you can cut the copper pipes to fit your application.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_details\"\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Disconnect Box \u0026amp; Electrical\" href=\"https:\/\/gotductless.com\/collections\/refrigerant-kits\" target=\"_blank\"\u003eDisconnect Box \u0026amp; Electrical Whip Kit \u003c\/a\u003e-\u003c\/span\u003e The disconnect \u0026amp; whip kit comes in each installation kit. It provides a safe and simple way to connect your outdoor condenser to your homes' electrical panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Mounting Kits\" href=\"https:\/\/gotductless.com\/collections\/mounting-kits\"\u003eOutdoor Condenser Plastic Pad (Optional)\u003c\/a\u003e - T\u003c\/span\u003ehis pad provides an even surface, free of debris, on which to place your outdoor condenser. It's included with multi-zone systems orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Mounting Kits\" href=\"https:\/\/gotductless.com\/collections\/mounting-kits\" target=\"_blank\"\u003eWall Bracket (Optional)\u003c\/a\u003e -\u003c\/span\u003e A simple and sturdy way to mount your outdoor condensing unit off of the ground and attached to your home. It's included with multi-zone systems orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Mitsubishi Port Adapters\" href=\"https:\/\/gotductless.com\/products\/mitsubishi-adp5834-port-adapter\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003ePort Adapters  (Optiona\u003c\/span\u003el)\u003c\/a\u003e - Port adapters are sometimes necessary when connecting multiple indoor units to an outdoor unit. See installation manual to see when these items are necessary.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003clabel\u003eUnit Type\u003c\/label\u003e 1.66-Ton Inverter Condenser\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eProduct Line\u003c\/label\u003e M-Series\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eOperating Mode\u003c\/label\u003e Cooling \u0026amp; Heating\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eLow Ambient Heat: \u003c\/label\u003eNO \u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eNumber of Zones\u003c\/label\u003e 2\u003c\/li\u003e\n\u003cli\u003eUnit Capacity 20,000 BTU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eIncludes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003clabel\u003eOutdoor Unit\u003c\/label\u003e MXZ-2C20NA3-U1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"grid__item medium-up--one-half\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003clabel\u003eCooling Capacity\u003c\/label\u003e up to 20,000 BTU\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eHeating Capacity\u003c\/label\u003e up to 25,500 BTU\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eSEER2\u003c\/label\u003e Up to 20.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eEER2 Up to 12.7\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eHSPF2\u003c\/label\u003e Up to 10.0\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eHeating Minimum Temp\u003c\/label\u003e 5 F\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eCooling Minimum Temp\u003c\/label\u003e 14 F\u003c\/li\u003e\n\u003cli\u003e\n\u003clabel\u003eRoom Cooling\/Heating Capacity\u003c\/label\u003e up to 850 sq ft\u003c\/li\u003e\n\u003cli\u003eNoise Level: Cooling: 50 dB(A) \u003c\/li\u003e\n\u003cli\u003eNoise Level: Heating - 54 dB(A) \u003c\/li\u003e\n\u003cli\u003eSize W: 33 1\/16\"\u003c\/li\u003e\n\u003cli\u003eSize: H: 27 11\/16\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSize: D: 13\"\u003c\/li\u003e\n\u003cli\u003eWeight: 126 lbs\u003c\/li\u003e\n\u003cli\u003ePre-Charged: 5 lbs 15 oz\u003c\/li\u003e\n\u003cli\u003eElectrical: 20 AMP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1gn4ltu\" data-start=\"27\" data-end=\"359\"\u003e\n\u003cp data-start=\"29\" data-end=\"359\"\u003e\u003cstrong data-start=\"29\" data-end=\"72\"\u003eReliable 2‑Zone Heat Pump Outdoor Unit:\u003c\/strong\u003e The \u003cstrong data-start=\"77\" data-end=\"130\"\u003eMitsubishi MXZ‑2C20NA 20,000 BTU 2‑Zone Heat Pump\u003c\/strong\u003e delivers balanced \u003cstrong data-start=\"149\" data-end=\"184\" data-is-only-node=\"\"\u003ecooling and heating performance\u003c\/strong\u003e for multiple rooms from a single outdoor condenser — ideal for homes or small offices seeking flexible climate control across two zones. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"148dzcl\" data-start=\"361\" data-end=\"647\"\u003e\n\u003cp data-start=\"363\" data-end=\"647\"\u003e\u003cstrong data-start=\"363\" data-end=\"400\"\u003eMulti‑Room Comfort from One Unit:\u003c\/strong\u003e Designed to connect with \u003cstrong data-start=\"426\" data-end=\"450\"\u003eup to 2 indoor units\u003c\/strong\u003e, it lets you individually control temperature settings in each space without separate outdoor units, reducing equipment footprint and installation complexity. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ooufow\" data-start=\"649\" data-end=\"904\"\u003e\n\u003cp data-start=\"651\" data-end=\"904\"\u003e\u003cstrong data-start=\"651\" data-end=\"693\"\u003eEfficient Inverter‑Driven Performance:\u003c\/strong\u003e The \u003cstrong data-start=\"698\" data-end=\"736\"\u003evariable‑speed inverter compressor\u003c\/strong\u003e adapts output to real‑time demand, improving energy efficiency and reducing temperature swings compared with traditional systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1brlxil\" data-start=\"906\" data-end=\"1141\"\u003e\n\u003cp data-start=\"908\" data-end=\"1141\"\u003e\u003cstrong data-start=\"908\" data-end=\"948\"\u003eQuiet and Durable Outdoor Operation:\u003c\/strong\u003e Engineered for \u003cstrong data-start=\"964\" data-end=\"984\"\u003elow noise levels\u003c\/strong\u003e during operation and equipped with features like intelligent power management for reduced loss and stable performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2ivyi7\" data-start=\"1143\" data-end=\"1321\"\u003e\n\u003cp data-start=\"1145\" data-end=\"1321\"\u003e\u003cstrong data-start=\"1145\" data-end=\"1167\"\u003eEnergy‑Smart Core:\u003c\/strong\u003e ENERGY STAR® efficiency helps lower utility costs through smarter cooling\/heating cycles while maintaining comfort. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hb6k5o\" data-start=\"1323\" data-end=\"1552\"\u003e\n\u003cp data-start=\"1325\" data-end=\"1552\"\u003e\u003cstrong data-start=\"1325\" data-end=\"1350\"\u003eWide Operating Range:\u003c\/strong\u003e Built to support performance across typical seasonal extremes, providing comfort in both summer and winter (actual connected capacities vary by indoor unit types). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b6hrms\" data-start=\"1554\" data-end=\"1758\"\u003e\n\u003cp data-start=\"1556\" data-end=\"1758\"\u003e\u003cstrong data-start=\"1556\" data-end=\"1586\"\u003eDurability and Protection:\u003c\/strong\u003e Standard safety and protection features, such as thermal lockout\/restart and high‑pressure protection, improve long‑term reliability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1blvd2g\" data-start=\"1760\" data-end=\"2040\"\u003e\n\u003cp data-start=\"1762\" data-end=\"2040\"\u003e\u003cstrong data-start=\"1762\" data-end=\"1781\"\u003eExpert Verdict:\u003c\/strong\u003e A versatile choice for homes needing \u003cstrong data-start=\"1819\" data-end=\"1891\"\u003edual‑zone HVAC control with efficient year‑round cooling and heating\u003c\/strong\u003e, offering quieter operation, flexible zoning, and energy‑saving benefits from a single outdoor heat pump unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"93\" data-end=\"353\"\u003e\u003cstrong data-start=\"93\" data-end=\"152\"\u003eQ: What type of HVAC unit is the Mitsubishi MXZ‑2C20NA?\u003c\/strong\u003e\u003cbr data-start=\"152\" data-end=\"155\"\u003eA: It’s a \u003cstrong data-start=\"165\" data-end=\"207\"\u003emulti‑zone heat pump outdoor condenser\u003c\/strong\u003e that supports \u003cstrong data-start=\"222\" data-end=\"246\"\u003eup to 2 indoor units\u003c\/strong\u003e for ductless mini‑split systems, providing both cooling and heating. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"355\" data-end=\"611\"\u003e\u003cstrong data-start=\"355\" data-end=\"404\"\u003eQ: What is the nominal capacity of this unit?\u003c\/strong\u003e\u003cbr data-start=\"404\" data-end=\"407\"\u003eA: The outdoor unit has a \u003cstrong data-start=\"433\" data-end=\"472\"\u003e20,000 BTU nominal cooling capacity\u003c\/strong\u003e and delivers strong heating capacity suitable for medium‑sized spaces when paired with indoor units. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"613\" data-end=\"791\"\u003e\u003cstrong data-start=\"613\" data-end=\"649\"\u003eQ: What refrigerant does it use?\u003c\/strong\u003e\u003cbr data-start=\"649\" data-end=\"652\"\u003eA: This model uses \u003cstrong data-start=\"671\" data-end=\"693\"\u003eR‑410A refrigerant\u003c\/strong\u003e, a widely used option in existing mini‑split installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"793\" data-end=\"977\"\u003e\u003cstrong data-start=\"793\" data-end=\"830\"\u003eQ: How many zones can it support?\u003c\/strong\u003e\u003cbr data-start=\"830\" data-end=\"833\"\u003eA: It supports \u003cstrong data-start=\"848\" data-end=\"892\"\u003etwo independent zones (two indoor units)\u003c\/strong\u003e for flexible room‑by‑room cooling and heating. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"979\" data-end=\"1270\"\u003e\u003cstrong data-start=\"979\" data-end=\"1048\"\u003eQ: What kind of efficiency and performance features does it have?\u003c\/strong\u003e\u003cbr data-start=\"1048\" data-end=\"1051\"\u003eA: The unit incorporates a \u003cstrong data-start=\"1078\" data-end=\"1116\"\u003evariable‑speed inverter compressor\u003c\/strong\u003e, operates quietly, and can achieve \u003cstrong data-start=\"1152\" data-end=\"1204\"\u003eup to ~20 SEER2 and ~10 HSPF2 efficiency ratings\u003c\/strong\u003e, helping reduce energy use. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1272\" data-end=\"1460\"\u003e\u003cstrong data-start=\"1272\" data-end=\"1318\"\u003eQ: Does it have Energy Star certification?\u003c\/strong\u003e\u003cbr data-start=\"1318\" data-end=\"1321\"\u003eA: Yes — this model is \u003cstrong data-start=\"1344\" data-end=\"1369\"\u003eEnergy Star certified\u003c\/strong\u003e for efficient performance and lower operating costs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1462\" data-end=\"1692\"\u003e\u003cstrong data-start=\"1462\" data-end=\"1507\"\u003eQ: What are typical operating conditions?\u003c\/strong\u003e\u003cbr data-start=\"1507\" data-end=\"1510\"\u003eA: It operates in both \u003cstrong data-start=\"1533\" data-end=\"1562\"\u003ecooling and heating modes\u003c\/strong\u003e across a wide range of ambient temperatures and restarts automatically after power outages. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1694\" data-end=\"1921\"\u003e\u003cstrong data-start=\"1694\" data-end=\"1746\"\u003eQ: What indoor unit capacities can it pair with?\u003c\/strong\u003e\u003cbr data-start=\"1746\" data-end=\"1749\"\u003eA: Compatible with a combination of indoor units that total up to roughly \u003cstrong data-start=\"1823\" data-end=\"1855\"\u003e24,000 BTU combined capacity\u003c\/strong\u003e (e.g., two 12 k BTU units). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1923\" data-end=\"2199\"\u003e\u003cstrong data-start=\"1923\" data-end=\"1977\"\u003eQ: What are its electrical and installation specs?\u003c\/strong\u003e\u003cbr data-start=\"1977\" data-end=\"1980\"\u003eA: The outdoor unit runs on \u003cstrong data-start=\"2008\" data-end=\"2048\"\u003e208\/230 V single‑phase power (60 Hz)\u003c\/strong\u003e with standard refrigerant line connections, and it includes built‑in protective features like pressure switches.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul data-start=\"89\" data-end=\"1816\"\u003e\n\u003cli data-section-id=\"5zyvv0\" data-start=\"89\" data-end=\"353\"\u003e\n\u003cp data-start=\"91\" data-end=\"353\"\u003e\u003cstrong data-start=\"91\" data-end=\"127\"\u003eKeep Outdoor Unit Clean \u0026amp; Clear:\u003c\/strong\u003e Remove leaves, debris, snow, and vegetation around the outdoor unit to maintain proper airflow and efficient heat exchange. Blocked airflow reduces performance and increases energy use. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16ad8k9\" data-start=\"354\" data-end=\"587\"\u003e\n\u003cp data-start=\"356\" data-end=\"587\"\u003e\u003cstrong data-start=\"356\" data-end=\"388\"\u003eClean the Condenser Surface:\u003c\/strong\u003e Use a soft dry cloth or lightly damp cloth to wipe the outdoor condenser’s surface; avoid harsh chemicals and direct water spray to prevent electrical issues. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gigr4t\" data-start=\"588\" data-end=\"794\"\u003e\n\u003cp data-start=\"590\" data-end=\"794\"\u003e\u003cstrong data-start=\"590\" data-end=\"623\"\u003eInspect Air Inlets \u0026amp; Outlets:\u003c\/strong\u003e Before use, ensure outdoor air inlets and outlets are free of blockages to keep airflow unobstructed and system pressure balanced. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12p7w1m\" data-start=\"795\" data-end=\"965\"\u003e\n\u003cp data-start=\"797\" data-end=\"965\"\u003e\u003cstrong data-start=\"797\" data-end=\"816\"\u003eCheck Drainage:\u003c\/strong\u003e Verify that condensate drain paths are unobstructed to avoid water buildup and potential corrosion or leaks. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7ezqt4\" data-start=\"966\" data-end=\"1198\"\u003e\n\u003cp data-start=\"968\" data-end=\"1198\"\u003e\u003cstrong data-start=\"968\" data-end=\"1002\"\u003eSecure Electrical Connections:\u003c\/strong\u003e Periodically verify that electrical connections and circuit breaker components show no signs of wear or looseness to prevent performance issues or hazards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o62ya4\" data-start=\"1199\" data-end=\"1410\"\u003e\n\u003cp data-start=\"1201\" data-end=\"1410\"\u003e\u003cstrong data-start=\"1201\" data-end=\"1229\"\u003eUse Correct Refrigerant:\u003c\/strong\u003e Only use and service the system with the specified \u003cstrong data-start=\"1281\" data-end=\"1290\"\u003eR410A\u003c\/strong\u003e refrigerant; improper refrigerants can damage the system and pose safety risks. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n2kz8c\" data-start=\"1411\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1413\" data-end=\"1617\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1445\"\u003eAnnual Professional Service:\u003c\/strong\u003e Have a certified HVAC technician inspect refrigerant levels, coils, electrical components, and safe operation at least once a year. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4eneng\" data-start=\"1618\" data-end=\"1816\"\u003e\n\u003cp data-start=\"1620\" data-end=\"1816\"\u003e\u003cstrong data-start=\"1620\" data-end=\"1644\"\u003eMonitor Performance:\u003c\/strong\u003e If cooling\/heating output weakens or unusual noises occur, contact a technician promptly — early diagnosis prevents larger repairs. \u003cspan class=\"\" data-state=\"delayed-open\" aria-describedby=\"radix-_r_gi_\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":43533462306890,"sku":"MXZ-2C20NA","price":1126.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/Screen_Shot_2019-06-14_at_9.46.33_AM.png?v=1776877218","url":"https:\/\/wen0d6-q0.myshopify.com\/es\/products\/mitsubishi-20-000-btu-mxz-2c20na-two-zone-heat-pump-unit","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}