{"product_id":"goodman-1-5-ton-18-000-btu-heat-pump-condenser-seer2-14-3-single-stage-r32","title":"Goodman - 1.5 Ton\/18,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA1810","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 1.5 Ton\/18,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA1810\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Goodman 1.5 Ton 15.2 SEER2 Heat Pump Condenser (R-32) - GLZS4BA1810 will provide you with reliable cooling and heating at money-saving energy efficiency levels as compared to lower SEER heat pump units. Your Goodman heat pump condenser starts with an energy-efficient compressor, which operates in tandem with our high-efficiency coil. These high-quality components together cool and heat your home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePlease note this is an outdoor unit only, for full system operation this needs to be paired with an indoor unit.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal size to cover a smaller house in ideal climates\u003c\/li\u003e\n\u003cli\u003e1.5 ton, 14.3 SEER2 heat pump condenser\u003c\/li\u003e\n\u003cli\u003eR32: Complies with Clean Air Act New Refrigerant Requirements\u003c\/li\u003e\n\u003cli\u003eLow sound output\u003c\/li\u003e\n\u003cli\u003eFully charged for up to 15' of line set\u003c\/li\u003e\n\u003cli\u003eFactory-installed bi-flow filter drier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" class=\"tg-wa1i\"\u003e1.5 Ton 14.3 SEER2 Goodman Heat Pump - R32\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGLZS4BA1810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e165.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eReplaces\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGSZ140181, GSZ140191, GSZB401810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Speed PSC Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHorsepower\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1\/6 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSEER2 (Efficiency)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e14.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e208\/230v 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e15 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e11.2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e32 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e29\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e29\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman_Heat_Pump_Install_Manual_v2023.pdf?v=1724741236\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GLZS4B_spec_sheet.pdf?v=1724741233\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eSpec Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"q0mlfz\" data-start=\"27\" data-end=\"308\"\u003e\n\u003cp data-start=\"29\" data-end=\"308\"\u003e\u003cstrong data-start=\"29\" data-end=\"62\"\u003eReliable 3‑Ton Cooling Power:\u003c\/strong\u003e The \u003cstrong data-start=\"67\" data-end=\"108\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eGoodman GLXS4BA3610 Air Conditioner Split System\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e delivers \u003cstrong data-start=\"118\" data-end=\"141\" data-is-only-node=\"\"\u003e36,000 BTU (3 tons)\u003c\/strong\u003e of cooling, making it a \u003cstrong data-start=\"166\" data-end=\"206\"\u003estrong choice for medium‑sized homes\u003c\/strong\u003e and larger living spaces with steady temperature control needs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"130e7lp\" data-start=\"310\" data-end=\"572\"\u003e\n\u003cp data-start=\"312\" data-end=\"572\"\u003e\u003cstrong data-start=\"312\" data-end=\"340\"\u003eSolid SEER2 Performance:\u003c\/strong\u003e With an \u003cstrong data-start=\"349\" data-end=\"369\"\u003eup to 14.3 SEER2\u003c\/strong\u003e rating, this system balances \u003cstrong data-start=\"399\" data-end=\"449\" data-is-only-node=\"\"\u003eenergy efficiency and operational cost savings\u003c\/strong\u003e — ideal for homeowners seeking a \u003cstrong data-start=\"483\" data-end=\"533\"\u003ebudget‑friendly yet efficient cooling solution\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17iw5ex\" data-start=\"574\" data-end=\"830\"\u003e\n\u003cp data-start=\"576\" data-end=\"830\"\u003e\u003cstrong data-start=\"576\" data-end=\"603\"\u003eR‑32 Refrigerant Ready:\u003c\/strong\u003e Designed for use with \u003cstrong data-start=\"626\" data-end=\"645\"\u003eR32 refrigerant\u003c\/strong\u003e, the unit delivers \u003cstrong data-start=\"665\" data-end=\"723\" data-is-only-node=\"\"\u003eeffective heat transfer and lower environmental impact\u003c\/strong\u003e compared to older refrigerants, aligning with modern HVAC standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1elgz7d\" data-start=\"832\" data-end=\"1106\"\u003e\n\u003cp data-start=\"834\" data-end=\"1106\"\u003e\u003cstrong data-start=\"834\" data-end=\"867\"\u003eMulti‑Positional Flexibility:\u003c\/strong\u003e The multi‑positional design supports \u003cstrong data-start=\"905\" data-end=\"954\"\u003eupflow, downflow, or horizontal installations\u003c\/strong\u003e, giving \u003cstrong data-start=\"963\" data-end=\"994\" data-is-only-node=\"\"\u003einstallers more flexibility\u003c\/strong\u003e to fit the unit into \u003cstrong data-start=\"1016\" data-end=\"1067\"\u003evaried duct layouts and tight mechanical spaces\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ort3ce\" data-start=\"1108\" data-end=\"1309\"\u003e\n\u003cp data-start=\"1110\" data-end=\"1309\"\u003e\u003cstrong data-start=\"1110\" data-end=\"1136\"\u003eDurable Outdoor Build:\u003c\/strong\u003e Built with a \u003cstrong data-start=\"1150\" data-end=\"1209\"\u003egalvanized steel cabinet and corrosion‑resistant finish\u003c\/strong\u003e for \u003cstrong data-start=\"1214\" data-end=\"1270\" data-is-only-node=\"\"\u003elong‑lasting outdoor exposure and weather resistance\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w25f51\" data-start=\"1311\" data-end=\"1544\"\u003e\n\u003cp data-start=\"1313\" data-end=\"1544\"\u003e\u003cstrong data-start=\"1313\" data-end=\"1345\"\u003eQuiet \u0026amp; Efficient Operation:\u003c\/strong\u003e Engineered with \u003cstrong data-start=\"1362\" data-end=\"1423\"\u003esound‑dampening features and a standard scroll compressor\u003c\/strong\u003e, this system delivers \u003cstrong data-start=\"1446\" data-end=\"1475\" data-is-only-node=\"\"\u003esteady, quiet performance\u003c\/strong\u003e throughout the cooling season. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q20uva\" data-start=\"1546\" data-end=\"1807\"\u003e\n\u003cp data-start=\"1548\" data-end=\"1807\"\u003e\u003cstrong data-start=\"1548\" data-end=\"1572\"\u003eStrong Value Choice:\u003c\/strong\u003e Combines \u003cstrong data-start=\"1582\" data-end=\"1662\"\u003etrusted Goodman reliability, energy efficiency, and installation flexibility\u003c\/strong\u003e, making it an \u003cstrong data-start=\"1677\" data-end=\"1722\" data-is-only-node=\"\"\u003eexcellent value‑oriented cooling solution\u003c\/strong\u003e for residential HVAC upgrades or replacements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"120\" data-end=\"372\"\u003e\u003cstrong data-start=\"120\" data-end=\"177\"\u003eQ: What type of HVAC unit is the Goodman GLZS4BA1810?\u003c\/strong\u003e\u003cbr data-start=\"177\" data-end=\"180\"\u003eA: It’s a \u003cstrong data-start=\"190\" data-end=\"234\"\u003e1.5 ton (18,000 BTU) heat pump condenser\u003c\/strong\u003e designed for \u003cstrong data-start=\"248\" data-end=\"276\"\u003eboth cooling and heating\u003c\/strong\u003e when paired with a matching indoor air handler or coil. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"374\" data-end=\"624\"\u003e\u003cstrong data-start=\"374\" data-end=\"407\"\u003eQ: What does SEER2 14.3 mean?\u003c\/strong\u003e\u003cbr data-start=\"407\" data-end=\"410\"\u003eA: \u003cstrong data-start=\"413\" data-end=\"427\"\u003eSEER2 14.3\u003c\/strong\u003e indicates seasonal cooling efficiency under updated testing standards — \u003cstrong data-start=\"500\" data-end=\"516\"\u003ehigher SEER2\u003c\/strong\u003e helps provide \u003cstrong data-start=\"531\" data-end=\"583\"\u003ebetter energy efficiency and lower utility costs\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"626\" data-end=\"849\"\u003e\u003cstrong data-start=\"626\" data-end=\"669\"\u003eQ: What refrigerant does this unit use?\u003c\/strong\u003e\u003cbr data-start=\"669\" data-end=\"672\"\u003eA: This unit uses \u003cstrong data-start=\"690\" data-end=\"709\"\u003eR32 refrigerant\u003c\/strong\u003e, a modern, \u003cstrong data-start=\"721\" data-end=\"782\"\u003emore efficient and lower‑environmental‑impact refrigerant\u003c\/strong\u003e compared with older types. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"851\" data-end=\"1104\"\u003e\u003cstrong data-start=\"851\" data-end=\"892\"\u003eQ: What are the heating capabilities?\u003c\/strong\u003e\u003cbr data-start=\"892\" data-end=\"895\"\u003eA: As a heat pump, it provides \u003cstrong data-start=\"926\" data-end=\"966\"\u003eup to 18,000 BTU of heating capacity\u003c\/strong\u003e (HSPF2 typically ~7.8) for mild to moderate climates when matched with suitable indoor equipment. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1106\" data-end=\"1298\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1153\"\u003eQ: What compressor and stages does it have?\u003c\/strong\u003e\u003cbr data-start=\"1153\" data-end=\"1156\"\u003eA: Features a \u003cstrong data-start=\"1170\" data-end=\"1204\"\u003esingle‑stage rotary compressor\u003c\/strong\u003e for \u003cstrong data-start=\"1209\" data-end=\"1257\"\u003esimple, reliable heating\/cooling performance\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1300\" data-end=\"1565\"\u003e\u003cstrong data-start=\"1300\" data-end=\"1350\"\u003eQ: What are the electrical and physical specs?\u003c\/strong\u003e\u003cbr data-start=\"1350\" data-end=\"1353\"\u003eA: Operates on \u003cstrong data-start=\"1368\" data-end=\"1400\"\u003e208\/230 V single‑phase power\u003c\/strong\u003e, typically needs \u003cstrong data-start=\"1418\" data-end=\"1466\"\u003e11.2 A min circuit ampacity and 15 A breaker\u003c\/strong\u003e. Dimensions ~\u003cstrong data-start=\"1480\" data-end=\"1507\"\u003e29″ W × 29″ D × 32.5″ H\u003c\/strong\u003e and ~\u003cstrong data-start=\"1513\" data-end=\"1524\"\u003e150 lbs\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1567\" data-end=\"1737\"\u003e\u003cstrong data-start=\"1567\" data-end=\"1609\"\u003eQ: How loud is this unit in operation?\u003c\/strong\u003e\u003cbr data-start=\"1609\" data-end=\"1612\"\u003eA: Typical sound level is around \u003cstrong data-start=\"1645\" data-end=\"1655\"\u003e74 dBA\u003c\/strong\u003e, common for outdoor heat pump condensers.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1p7wmpk\" data-start=\"117\" data-end=\"259\"\u003e\n\u003cp data-start=\"119\" data-end=\"259\"\u003e\u003cstrong data-start=\"119\" data-end=\"146\"\u003eClean the Outdoor Coil:\u003c\/strong\u003e Remove leaves, dirt, and debris regularly to maintain efficient heat transfer and cooling\/heating performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1u0ahei\" data-start=\"260\" data-end=\"375\"\u003e\n\u003cp data-start=\"262\" data-end=\"375\"\u003e\u003cstrong data-start=\"262\" data-end=\"292\"\u003eMaintain Proper Clearance:\u003c\/strong\u003e Keep at least \u003cstrong data-start=\"307\" data-end=\"326\"\u003e2–3 ft of space\u003c\/strong\u003e around the condenser for unrestricted airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ea15we\" data-start=\"376\" data-end=\"477\"\u003e\n\u003cp data-start=\"378\" data-end=\"477\"\u003e\u003cstrong data-start=\"378\" data-end=\"408\"\u003eInspect Refrigerant Lines:\u003c\/strong\u003e Check \u003cstrong data-start=\"415\" data-end=\"443\"\u003eliquid and suction lines\u003c\/strong\u003e for insulation damage or leaks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ylhxx4\" data-start=\"478\" data-end=\"568\"\u003e\n\u003cp data-start=\"480\" data-end=\"568\"\u003e\u003cstrong data-start=\"480\" data-end=\"502\"\u003eRinse Fins Gently:\u003c\/strong\u003e Use a garden hose to clean condenser fins without bending them.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"h0dvh3\" data-start=\"569\" data-end=\"680\"\u003e\n\u003cp data-start=\"571\" data-end=\"680\"\u003e\u003cstrong data-start=\"571\" data-end=\"604\"\u003eCheck Electrical Connections:\u003c\/strong\u003e Ensure wiring, disconnects, and capacitors are secure and corrosion-free.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wg7ky3\" data-start=\"681\" data-end=\"829\"\u003e\n\u003cp data-start=\"683\" data-end=\"829\"\u003e\u003cstrong data-start=\"683\" data-end=\"715\"\u003eMonitor Performance \u0026amp; Noise:\u003c\/strong\u003e Normal operation should be quiet; unusual sounds or reduced heating\/cooling may indicate maintenance is needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c20up2\" data-start=\"830\" data-end=\"997\"\u003e\n\u003cp data-start=\"832\" data-end=\"997\"\u003e\u003cstrong data-start=\"832\" data-end=\"873\"\u003eSchedule Annual Professional Service:\u003c\/strong\u003e A licensed HVAC technician should inspect the \u003cstrong data-start=\"920\" data-end=\"987\"\u003ecompressor, fan motor, refrigerant charge, and system pressures\u003c\/strong\u003e yearly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533434126410,"sku":"GLZS4BA1810","price":1669.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/gsz_front_right_1_1_17f2ef46-4bd9-4802-b3ed-9a8c5a029eb1.webp?v=1776875619","url":"https:\/\/wen0d6-q0.myshopify.com\/products\/goodman-1-5-ton-18-000-btu-heat-pump-condenser-seer2-14-3-single-stage-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}