{"product_id":"goodman-100-000-btu-97-variable-speed-modulating-gas-furnace-21-width-upflow-horizontal-115v-r32","title":"Goodman - 100,000 BTU 97% Variable Speed Modulating Gas Furnace - 21\" Width - Upflow \/ Horizontal - 115V - R32 - GRVM971005CN","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 100,000 BTU 97% Variable Speed Modulating Gas Furnace - 21\" Width - Upflow \/ Horizontal - 115V - R32 - GRVM971005CN\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWith a 97% efficiency rating, a variable-speed blower motor, and modulating gas valves, the GRVM971005CN is part of Goodman's top-tier furnace series. If you're looking to reduce your gas bill, the GRVM971005CN is an excellent choice, offering one of the best efficiency levels available on the market.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal to heat a small to medium house (in an ideal climate)\u003c\/li\u003e\n\u003cli\u003e100,000 BTU 97% AFUE modulating variable speed natural gas furnace\u003c\/li\u003e\n\u003cli\u003eRequires plastic\/PVC flue venting\u003c\/li\u003e\n\u003cli\u003eCan be installed in the upflow or horizontal orientation\u003c\/li\u003e\n\u003cli\u003eCan be converted to propane with an LP conversion kit (sold separately)\u003c\/li\u003e\n\u003cli\u003eInnovative design for electrical efficiency, safety, and lower sound output\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-4x00{background-color:#ffffff;border-color:#000000;color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-4x00\" colspan=\"2\"\u003eGoodman 97% 100,000 BTU Variable Speed Modulating Gas Furnace - 21\" Width - Upflow \/ Horizontal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGRVM971005CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e144.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eExhaust Flue Requirement\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003ePlastic \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eR-32 Compliant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eProduct Features\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eNew Refrigerant Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eFurnace Efficiency \/ AFUE\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eEnergy Star\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eBurner Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eModulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003ePropane, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e34 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e28 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GRVM97-GDVM97-Install-Manual.pdf?v=1760255220\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GR9T96-GD9T96-Install-Manual.pdf?v=1759999427\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-R32-GDVM97-Spec-Sheet.pdf?v=1760255214\" target=\"_blank\"\u003e\u003cstrong\u003eSpecifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"343\" data-start=\"27\" data-section-id=\"1oeb4i0\"\u003e\n\u003cp data-end=\"343\" data-start=\"29\"\u003e\u003cstrong data-end=\"69\" data-start=\"29\"\u003eOutstanding Efficiency \u0026amp; Performance\u003c\/strong\u003e\u003cbr data-end=\"72\" data-start=\"69\"\u003eThe \u003cstrong data-end=\"152\" data-start=\"78\"\u003eGoodman GRVM971005CN 100,000 BTU Variable‑Speed Modulating Gas Furnace\u003c\/strong\u003e delivers \u003cstrong data-is-only-node=\"\" data-end=\"175\" data-start=\"162\"\u003e97 % AFUE\u003c\/strong\u003e, converting nearly all fuel into usable heat to \u003cstrong data-end=\"266\" data-start=\"224\"\u003elower energy costs and improve comfort\u003c\/strong\u003e compared with lower‑efficiency models. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"681\" data-start=\"345\" data-section-id=\"jnc8ae\"\u003e\n\u003cp data-end=\"681\" data-start=\"347\"\u003e\u003cstrong data-end=\"382\" data-start=\"347\"\u003eTrue Modulating Comfort Control\u003c\/strong\u003e\u003cbr data-end=\"385\" data-start=\"382\"\u003eA \u003cstrong data-end=\"430\" data-start=\"389\"\u003eself‑calibrating modulating gas valve\u003c\/strong\u003e and \u003cstrong data-is-only-node=\"\" data-end=\"464\" data-start=\"435\"\u003evariable‑speed ECM blower\u003c\/strong\u003e continuously adjust heat output and airflow to match demand, reducing temperature swings and providing \u003cstrong data-end=\"603\" data-start=\"568\"\u003equieter, more consistent warmth\u003c\/strong\u003e than traditional single‑stage furnaces. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"964\" data-start=\"683\" data-section-id=\"ym9l4z\"\u003e\n\u003cp data-end=\"964\" data-start=\"685\"\u003e\u003cstrong data-end=\"718\" data-start=\"685\"\u003eSmart, Integrated Diagnostics\u003c\/strong\u003e\u003cbr data-end=\"721\" data-start=\"718\"\u003eBuilt‑in \u003cstrong data-end=\"760\" data-start=\"732\"\u003eself‑diagnostic controls\u003c\/strong\u003e, \u003cstrong data-is-only-node=\"\" data-end=\"808\" data-start=\"762\"\u003eComfortBridge™ communication compatibility\u003c\/strong\u003e, and optional \u003cstrong data-end=\"862\" data-start=\"823\"\u003eBluetooth commissioning\/diagnostics\u003c\/strong\u003e simplify setup and service while optimizing system performance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1267\" data-start=\"966\" data-section-id=\"1kjojjc\"\u003e\n\u003cp data-end=\"1267\" data-start=\"968\"\u003e\u003cstrong data-end=\"999\" data-start=\"968\"\u003eDurable, Quiet Construction\u003c\/strong\u003e\u003cbr data-end=\"1002\" data-start=\"999\"\u003eFeatures \u003cstrong data-end=\"1092\" data-start=\"1013\"\u003eheavy‑duty aluminized primary and stainless‑steel secondary heat exchangers\u003c\/strong\u003e, a sealed insulated cabinet, and a variable‑speed induced‑draft blower for \u003cstrong data-is-only-node=\"\" data-end=\"1212\" data-start=\"1168\"\u003erobust reliability and quieter operation\u003c\/strong\u003e in everyday use. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1588\" data-start=\"1269\" data-section-id=\"12cnsg4\"\u003e\n\u003cp data-end=\"1588\" data-start=\"1271\"\u003e\u003cstrong data-end=\"1306\" data-start=\"1271\"\u003eFlexible Installation \u0026amp; Venting\u003c\/strong\u003e\u003cbr data-end=\"1309\" data-start=\"1306\"\u003eDesigned for \u003cstrong data-end=\"1362\" data-start=\"1324\"\u003eupflow or horizontal configuration\u003c\/strong\u003e with easy‑venting options (direct or non‑direct), convenient left\/right gas and electrical service access, and low cabinet air leakage (≤ 2 %), aiding both retrofit and new installations. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1877\" data-start=\"1590\" data-section-id=\"6f9zqk\"\u003e\n\u003cp data-end=\"1877\" data-start=\"1592\"\u003e\u003cstrong data-end=\"1635\" data-start=\"1592\"\u003eModern Emissions \u0026amp; System Compatibility\u003c\/strong\u003e\u003cbr data-end=\"1638\" data-start=\"1635\"\u003eIncludes \u003cstrong data-end=\"1678\" data-start=\"1649\"\u003eLow NOx burner compliance\u003c\/strong\u003e and works with a range of thermostats (communicating or conventional), air cleaners, and humidifiers—making it a forward‑looking choice for modern HVAC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-end=\"400\" data-start=\"99\"\u003e\u003cstrong data-end=\"136\" data-start=\"99\"\u003eQ1: What type of furnace is this?\u003c\/strong\u003e\u003cbr data-end=\"139\" data-start=\"136\"\u003eA: The \u003cstrong data-end=\"170\" data-start=\"146\"\u003eGoodman GRVM971005CN\u003c\/strong\u003e is a \u003cstrong data-end=\"207\" data-start=\"176\"\u003ehigh‑efficiency gas furnace\u003c\/strong\u003e with a \u003cstrong data-end=\"239\" data-start=\"215\"\u003emodulating gas valve\u003c\/strong\u003e and \u003cstrong data-end=\"279\" data-start=\"244\"\u003evariable‑speed ECM blower motor\u003c\/strong\u003e that adjusts output to match heating demand for consistent comfort and efficiency. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"683\" data-start=\"402\"\u003e\u003cstrong data-end=\"467\" data-start=\"402\"\u003eQ2: How much heating capacity and efficiency does it deliver?\u003c\/strong\u003e\u003cbr data-end=\"470\" data-start=\"467\"\u003eA: This model delivers \u003cstrong data-end=\"535\" data-start=\"493\"\u003e100,000 BTU input (≈97,000 BTU output)\u003c\/strong\u003e at \u003cstrong data-end=\"552\" data-start=\"539\"\u003e97 % AFUE\u003c\/strong\u003e, meaning nearly all fuel energy is used for heat — reducing waste and lowering energy costs. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"916\" data-start=\"685\"\u003e\u003cstrong data-end=\"738\" data-start=\"685\"\u003eQ3: What installation orientations are supported?\u003c\/strong\u003e\u003cbr data-end=\"741\" data-start=\"738\"\u003eA: It supports \u003cstrong data-end=\"795\" data-start=\"756\"\u003eupflow and horizontal installations\u003c\/strong\u003e, ideal for basements, attics, closets, or crawlspaces with different duct layouts. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1214\" data-start=\"918\"\u003e\u003cstrong data-end=\"983\" data-start=\"918\"\u003eQ4: What advanced motor and control features does it include?\u003c\/strong\u003e\u003cbr data-end=\"986\" data-start=\"983\"\u003eA: The furnace features a \u003cstrong data-end=\"1041\" data-start=\"1012\"\u003evariable‑speed ECM blower\u003c\/strong\u003e for smooth airflow and quieter operation, plus \u003cstrong data-end=\"1130\" data-start=\"1089\"\u003eComfortBridge™ communicating controls\u003c\/strong\u003e with Bluetooth commissioning and diagnostics. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1558\" data-start=\"1216\"\u003e\u003cstrong data-end=\"1280\" data-start=\"1216\"\u003eQ5: What construction and reliability features are included?\u003c\/strong\u003e\u003cbr data-end=\"1283\" data-start=\"1280\"\u003eA: It includes \u003cstrong data-end=\"1383\" data-start=\"1298\"\u003eheavy‑duty aluminized steel primary and stainless steel secondary heat exchangers\u003c\/strong\u003e, a \u003cstrong data-end=\"1414\" data-start=\"1387\"\u003esilicon nitride igniter\u003c\/strong\u003e, \u003cstrong data-end=\"1461\" data-start=\"1416\"\u003eself‑diagnostic control board with memory\u003c\/strong\u003e, and provisions for accessory air cleaners or humidifiers. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1798\" data-start=\"1560\"\u003e\u003cstrong data-end=\"1609\" data-start=\"1560\"\u003eQ6: What fuel and venting requirements apply?\u003c\/strong\u003e\u003cbr data-end=\"1612\" data-start=\"1609\"\u003eA: Runs on \u003cstrong data-end=\"1638\" data-start=\"1623\"\u003enatural gas\u003c\/strong\u003e (convertible to propane with a kit) and requires \u003cstrong data-end=\"1711\" data-start=\"1688\"\u003eplastic\/PVC venting\u003c\/strong\u003e typical for high‑efficiency condensing furnaces. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2051\" data-start=\"1800\"\u003e\u003cstrong data-end=\"1851\" data-start=\"1800\"\u003eQ7: What are the physical and electrical specs?\u003c\/strong\u003e\u003cbr data-end=\"1854\" data-start=\"1851\"\u003eA: Approximate dimensions are \u003cstrong data-end=\"1914\" data-start=\"1884\"\u003e34.5″ H × 21″ W × 28.75″ D\u003c\/strong\u003e, weight ~144 lb, and it operates on \u003cstrong data-end=\"1979\" data-start=\"1951\"\u003e115 V single‑phase power\u003c\/strong\u003e with up to \u003cstrong data-end=\"2012\" data-start=\"1991\"\u003e2,000 CFM airflow\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2271\" data-start=\"2053\"\u003e\u003cstrong data-end=\"2110\" data-start=\"2053\"\u003eQ8: What emissions and safety standards does it meet?\u003c\/strong\u003e\u003cbr data-end=\"2113\" data-start=\"2110\"\u003eA: It complies with \u003cstrong data-end=\"2164\" data-start=\"2133\"\u003eLow NOx emissions standards\u003c\/strong\u003e and is \u003cstrong data-end=\"2205\" data-start=\"2172\"\u003eAHRI certified and ETL listed\u003c\/strong\u003e for performance and safety.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"316\" data-start=\"143\" data-section-id=\"1f9mwit\"\u003e\n\u003cp data-end=\"316\" data-start=\"145\"\u003e\u003cstrong data-end=\"185\" data-start=\"145\"\u003eReplace Air Filters Every 1–3 Months\u003c\/strong\u003e – Keep the airflow strong and protect the blower and heat exchanger. Dirty filters reduce efficiency and increase system strain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"553\" data-start=\"318\" data-section-id=\"13ljf02\"\u003e\n\u003cp data-end=\"553\" data-start=\"320\"\u003e\u003cstrong data-end=\"354\" data-start=\"320\"\u003eAnnual Professional Inspection\u003c\/strong\u003e – Have a certified HVAC technician check burners, heat exchanger, PVC venting, modulation controls, gas pressure, and safety systems each season to maintain 97% AFUE efficiency and safe operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"728\" data-start=\"555\" data-section-id=\"9wz6l0\"\u003e\n\u003cp data-end=\"728\" data-start=\"557\"\u003e\u003cstrong data-end=\"583\" data-start=\"557\"\u003eClean Surrounding Area\u003c\/strong\u003e – Vacuum dust near the furnace and around intake\/exhaust areas; keep the furnace area free of clutter to support airflow and reduce fire risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"897\" data-start=\"730\" data-section-id=\"67q51u\"\u003e\n\u003cp data-end=\"897\" data-start=\"732\"\u003e\u003cstrong data-end=\"762\" data-start=\"732\"\u003eTest Thermostat \u0026amp; Controls\u003c\/strong\u003e – Verify thermostat accuracy, test modulation response, and replace batteries yearly if applicable to ensure smooth comfort control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1072\" data-start=\"899\" data-section-id=\"15abh4s\"\u003e\n\u003cp data-end=\"1072\" data-start=\"901\"\u003e\u003cstrong data-end=\"935\" data-start=\"901\"\u003eInspect Electrical Connections\u003c\/strong\u003e – Have the technician tighten connections, check variable‑speed motor components, and inspect the control board for corrosion or wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1261\" data-start=\"1074\" data-section-id=\"1e7q1me\"\u003e\n\u003cp data-end=\"1261\" data-start=\"1076\"\u003e\u003cstrong data-end=\"1117\" data-start=\"1076\"\u003eCheck PVC Intake\/Exhaust \u0026amp; Condensate\u003c\/strong\u003e – Ensure PVC vent pipes and any condensate drains are clear of obstructions (e.g., ice, nests, debris) that can affect combustion and drainage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1409\" data-start=\"1263\" data-section-id=\"1etzr58\"\u003e\n\u003cp data-end=\"1409\" data-start=\"1265\"\u003e\u003cstrong data-end=\"1293\" data-start=\"1265\"\u003eDocument All Maintenance\u003c\/strong\u003e – Track filter changes and professional service visits to support warranty coverage and streamline troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533438582858,"sku":"GRVM971005CN","price":2670.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/90_upflow_frontleft-800x800_1_16_c6906961-9ba4-453a-8057-7fa7ab36a20f.webp?v=1776875831","url":"https:\/\/wen0d6-q0.myshopify.com\/products\/goodman-100-000-btu-97-variable-speed-modulating-gas-furnace-21-width-upflow-horizontal-115v-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}