{"product_id":"goodman-2-5-ton-30-000-btu-heat-pump-condenser-seer2-14-3-single-stage-r32","title":"Goodman - 2.5 Ton\/30,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA3010","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 2.5 Ton\/30,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA3010\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Goodman GLZS4BA3010 heat pump condenser is a standard efficiency, low-cost solution for an all-electric home when paired with a suitable heat pump coil or air handler. Just like all of Goodman's equipment, the GLZS4BA3010 is manufactured with high-quality materials to provide a superior comfort in your home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePlease note this is an outdoor unit only, for full system operation this needs to be paired with an indoor unit.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal size to cover a smaller house in ideal climates\u003c\/li\u003e\n\u003cli\u003e2.5 ton, 14.3 SEER2 heat pump condenser\u003c\/li\u003e\n\u003cli\u003eR32: Complies with Clean Air Act New Refrigerant Requirements\u003c\/li\u003e\n\u003cli\u003eLow sound output\u003c\/li\u003e\n\u003cli\u003eFully charged for up to 15' of line set\u003c\/li\u003e\n\u003cli\u003eFactory-installed bi-flow filter drier\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wa1i\" colspan=\"2\"\u003e2.5 Ton 14.3 SEER2 Goodman Heat Pump - R32\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGLZS4BA3010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e190.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eReplaces\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGSZ140301, GSZB403010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCooling BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e30,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e30,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Speed PSC Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDecibel Level (dBA)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHorsepower\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1\/6 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSEER2 (Efficiency)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e14.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eScroll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Valve Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e208\/230v 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e15.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e39 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e29\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e29\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman_Heat_Pump_Install_Manual_v2023.pdf?v=1724741236\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GLZS4B_spec_sheet.pdf?v=1724741233\" target=\"_blank\"\u003e\u003cstrong\u003eSpec Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1bokmmn\" data-start=\"27\" data-end=\"390\"\u003e\n\u003cp data-start=\"29\" data-end=\"390\"\u003e\u003cstrong data-start=\"29\" data-end=\"80\"\u003eBalanced Seasonal Comfort with R‑32 Refrigerant\u003c\/strong\u003e\u003cbr data-start=\"80\" data-end=\"83\"\u003eThe \u003cstrong data-start=\"89\" data-end=\"140\"\u003eGoodman GLZS4BA3010 2.5 Ton Heat Pump Condenser\u003c\/strong\u003e delivers \u003cstrong data-start=\"150\" data-end=\"193\" data-is-only-node=\"\"\u003e30,000 BTU cooling and heating capacity\u003c\/strong\u003e with \u003cstrong data-start=\"199\" data-end=\"239\"\u003e14.3 SEER2 and ~7.8 HSPF2 efficiency\u003c\/strong\u003e, offering reliable year‑round comfort and \u003cstrong data-start=\"282\" data-end=\"320\"\u003emodern R‑32 refrigerant compliance\u003c\/strong\u003e for lower environmental impact. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7koxai\" data-start=\"392\" data-end=\"648\"\u003e\n\u003cp data-start=\"394\" data-end=\"648\"\u003e\u003cstrong data-start=\"394\" data-end=\"422\"\u003eSingle‑Stage Reliability\u003c\/strong\u003e\u003cbr data-start=\"422\" data-end=\"425\"\u003eIts \u003cstrong data-start=\"431\" data-end=\"465\"\u003esingle‑stage rotary compressor\u003c\/strong\u003e provides \u003cstrong data-start=\"475\" data-end=\"531\" data-is-only-node=\"\"\u003econsistent performance and straightforward operation\u003c\/strong\u003e—ideal for homeowners who want dependable heating \u0026amp; cooling without complexity. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pe9eda\" data-start=\"650\" data-end=\"917\"\u003e\n\u003cp data-start=\"652\" data-end=\"917\"\u003e\u003cstrong data-start=\"652\" data-end=\"691\"\u003eQuiet \u0026amp; Weather‑Ready Outdoor Build\u003c\/strong\u003e\u003cbr data-start=\"691\" data-end=\"694\"\u003eWith a \u003cstrong data-start=\"703\" data-end=\"724\"\u003e77 dB sound level\u003c\/strong\u003e, heavy‑gauge galvanized‑steel cabinet and removable grille design, the unit is built to withstand outdoor conditions while minimizing noise and corrosion. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ibvpm4\" data-start=\"919\" data-end=\"1224\"\u003e\n\u003cp data-start=\"921\" data-end=\"1224\"\u003e\u003cstrong data-start=\"921\" data-end=\"966\"\u003eSmartShift® Defrost \u0026amp; Protective Features\u003c\/strong\u003e\u003cbr data-start=\"966\" data-end=\"969\"\u003eSmartShift® technology ensures \u003cstrong data-start=\"1002\" data-end=\"1049\"\u003equiet, reliable defrost cycles in heat mode\u003c\/strong\u003e, while factory‑installed components like high‑capacity muffler, accumulator, and filter drier protect the system and enhance durability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1csgci7\" data-start=\"1226\" data-end=\"1492\"\u003e\n\u003cp data-start=\"1228\" data-end=\"1492\"\u003e\u003cstrong data-start=\"1228\" data-end=\"1262\"\u003eInstaller‑Friendly Connections\u003c\/strong\u003e\u003cbr data-start=\"1262\" data-end=\"1265\"\u003eService valves with easy access to gauge ports, sweat connections, and fully‑enclosed contactor with lug connection help HVAC pros complete installations and maintenance more efficiently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"57\" data-end=\"347\"\u003e\u003cstrong data-start=\"57\" data-end=\"96\"\u003eQ1: What type of HVAC unit is this?\u003c\/strong\u003e\u003cbr data-start=\"96\" data-end=\"99\"\u003eA: The \u003cstrong data-start=\"106\" data-end=\"129\"\u003eGoodman GLZS4BA3010\u003c\/strong\u003e is a \u003cstrong data-start=\"135\" data-end=\"166\"\u003e2.5 ton heat pump condenser\u003c\/strong\u003e designed for year‑round \u003cstrong data-start=\"191\" data-end=\"214\"\u003eheating and cooling\u003c\/strong\u003e in split‑system installations. It must be paired with a compatible indoor coil or air handler. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"349\" data-end=\"569\"\u003e\u003cstrong data-start=\"349\" data-end=\"394\"\u003eQ2: What efficiency ratings does it have?\u003c\/strong\u003e\u003cbr data-start=\"394\" data-end=\"397\"\u003eA: It delivers \u003cstrong data-start=\"412\" data-end=\"445\"\u003e14.3 SEER2 cooling efficiency\u003c\/strong\u003e and \u003cstrong data-start=\"450\" data-end=\"484\"\u003e~7.8 HSPF2 heating performance\u003c\/strong\u003e, offering balanced comfort and energy savings. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"571\" data-end=\"785\"\u003e\u003cstrong data-start=\"571\" data-end=\"621\"\u003eQ3: Which refrigerant does this heat pump use?\u003c\/strong\u003e\u003cbr data-start=\"621\" data-end=\"624\"\u003eA: This model uses \u003cstrong data-start=\"643\" data-end=\"663\"\u003eR‑32 refrigerant\u003c\/strong\u003e, a modern, lower‑environmental‑impact refrigerant with improved energy performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"787\" data-end=\"1027\"\u003e\u003cstrong data-start=\"787\" data-end=\"851\"\u003eQ4: What kind of compressor and operation does the unit use?\u003c\/strong\u003e\u003cbr data-start=\"851\" data-end=\"854\"\u003eA: It features a \u003cstrong data-start=\"871\" data-end=\"905\"\u003esingle‑stage rotary compressor\u003c\/strong\u003e with a \u003cstrong data-start=\"913\" data-end=\"953\"\u003esingle‑speed PSC condenser fan motor\u003c\/strong\u003e for reliable, consistent operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1029\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1079\"\u003eQ5: What key protective features are included?\u003c\/strong\u003e\u003cbr data-start=\"1079\" data-end=\"1082\"\u003eA: The unit includes \u003cstrong data-start=\"1103\" data-end=\"1236\"\u003efactory‑installed filter drier, suction‑line accumulator, crankcase heater, high‑capacity muffler, and high\/low‑pressure switches\u003c\/strong\u003e to help improve durability and performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1320\" data-end=\"1651\"\u003e\u003cstrong data-start=\"1320\" data-end=\"1373\"\u003eQ6: What cabinet and build features does it have?\u003c\/strong\u003e\u003cbr data-start=\"1373\" data-end=\"1376\"\u003eA: Built with a \u003cstrong data-start=\"1392\" data-end=\"1432\"\u003eheavy‑gauge galvanized‑steel cabinet\u003c\/strong\u003e, \u003cstrong data-start=\"1434\" data-end=\"1458\"\u003eremovable grille top\u003c\/strong\u003e, and \u003cstrong data-start=\"1464\" data-end=\"1491\"\u003esteel louver coil guard\u003c\/strong\u003e with a durable architectural gray finish — rated to resist corrosion and meet structural wind requirements when anchored. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1653\" data-end=\"1860\"\u003e\u003cstrong data-start=\"1653\" data-end=\"1706\"\u003eQ7: What are typical dimensions and sound levels?\u003c\/strong\u003e\u003cbr data-start=\"1706\" data-end=\"1709\"\u003eA: Approximate size is \u003cstrong data-start=\"1732\" data-end=\"1759\"\u003e29\" W × 29\" D × 39.5\" H\u003c\/strong\u003e, with typical sound levels around \u003cstrong data-start=\"1794\" data-end=\"1804\"\u003e77 dBA\u003c\/strong\u003e during operation.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"q86jzk\" data-start=\"121\" data-end=\"365\"\u003e\n\u003cp data-start=\"123\" data-end=\"365\"\u003e\u003cstrong data-start=\"123\" data-end=\"150\"\u003eKeep Outdoor Coil Clean\u003c\/strong\u003e – Regularly remove leaves, grass, and dirt from the condenser fins and wash gently with a hose (inside‑out) to maintain efficiency; avoid pressure washers that can bend fins. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tb4s9r\" data-start=\"366\" data-end=\"539\"\u003e\n\u003cp data-start=\"368\" data-end=\"539\"\u003e\u003cstrong data-start=\"368\" data-end=\"407\"\u003eMaintain Proper Airflow Around Unit\u003c\/strong\u003e – Ensure at least ~18–24″ clearance at sides and ~36″ in front so airflow isn’t restricted. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1u83t6c\" data-start=\"540\" data-end=\"746\"\u003e\n\u003cp data-start=\"542\" data-end=\"746\"\u003e\u003cstrong data-start=\"542\" data-end=\"583\"\u003eCheck Electrical Connections Annually\u003c\/strong\u003e – Inspect contactor, capacitor and wiring for loose or corroded connections that can reduce performance or cause failures. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fhfndq\" data-start=\"747\" data-end=\"949\"\u003e\n\u003cp data-start=\"749\" data-end=\"949\"\u003e\u003cstrong data-start=\"749\" data-end=\"780\"\u003eClear Drainage and Pad Area\u003c\/strong\u003e – Make sure the unit base is level and that water drains away from the pad to avoid corrosion and flooding around the condenser. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1upnv1u\" data-start=\"950\" data-end=\"1140\"\u003e\n\u003cp data-start=\"952\" data-end=\"1140\"\u003e\u003cstrong data-start=\"952\" data-end=\"981\"\u003eInspect Refrigerant Lines\u003c\/strong\u003e – Ensure R32 refrigerant lines are properly insulated and leak‑free; low charge reduces heating\/cooling effectiveness. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1odcg30\" data-start=\"1141\" data-end=\"1357\"\u003e\n\u003cp data-start=\"1143\" data-end=\"1357\"\u003e\u003cstrong data-start=\"1143\" data-end=\"1179\"\u003eAnnual HVAC Professional Service\u003c\/strong\u003e – Have a licensed technician check refrigerant levels, clean coils, test defrost operation, and verify the heat pump’s SEER2 performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533439041610,"sku":"GLZS4BA3010","price":1995.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/gsz_front_right_1_1_0d3a5fa2-7277-47f1-944a-0158a18515a4.webp?v=1776875859","url":"https:\/\/wen0d6-q0.myshopify.com\/products\/goodman-2-5-ton-30-000-btu-heat-pump-condenser-seer2-14-3-single-stage-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}