{"product_id":"goodman-60-000-btu-96-variable-speed-gas-furnace-17-5-width-downflow-horizontal-two-stage-115v-r32","title":"Goodman - 60,000 BTU 96% Variable Speed Gas Furnace - 17.5\" Width - Downflow \/ Horizontal - Two Stage - 115V - R32 - GDVT960603BN","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 60,000 BTU 96% Variable Speed Gas Furnace - 17.5\" Width - Downflow \/ Horizontal - Two Stage - 115V - R32 - GDVT960603BN\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWith a 96% efficiency rating, a variable-speed blower motor, and two stage gas valves, the GDVT960603BN is part of Goodman's top-tier furnace series. If you're looking to reduce your gas bill, the GDVT960603BN is an excellent choice, offering one of the best efficiency levels available on the market.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal to heat a small to medium house (in an ideal climate)\u003c\/li\u003e\n\u003cli\u003e60,000 BTU 96% AFUE modulating variable speed natural gas furnace\u003c\/li\u003e\n\u003cli\u003eRequires plastic\/PVC flue venting\u003c\/li\u003e\n\u003cli\u003eCan be installed in the downflow or horizontal orientation\u003c\/li\u003e\n\u003cli\u003eCan be converted to propane with an LP conversion kit (sold separately)\u003c\/li\u003e\n\u003cli\u003eInnovative design for electrical efficiency, safety, and lower sound output\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-4x00{background-color:#ffffff;border-color:#000000;color:#000000;font-weight:bold;text-align:center;vertical-align:middle}\n.tg .tg-8c31{background-color:#ffffff;border-color:#000000;color:#000000;text-align:left;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-4x00\"\u003eSKU\u003c\/th\u003e\n\u003cth class=\"tg-8c31\"\u003eGDVT960603BN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e119.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eExhaust Flue Requirement\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003ePlastic \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eR-32 Compliant\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eProduct Features\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eNew Refrigerant Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eFurnace Efficiency \/ AFUE\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e60,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eDownflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eEnergy Star\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003ePropane, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e34 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e17 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e28 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eLifetime Heat Exchanger, 10 Years Unit Replacement, and 10 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e35 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e22.4 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e27 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e66\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-4x00\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eOwner's Manual\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GRVT96-GDVT96-Install-Manual.pdf?v=1760249705\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eInstallation Manual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-R32-GDVT96-Spec-Sheet.pdf?v=1760249698\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eSpecifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"nwaltc\" data-start=\"344\" data-end=\"579\"\u003e\n\u003cp data-start=\"346\" data-end=\"579\"\u003e\u003cstrong data-start=\"346\" data-end=\"383\"\u003eOutstanding Efficiency (96% AFUE)\u003c\/strong\u003e\u003cbr data-start=\"383\" data-end=\"386\"\u003e• With \u003cstrong data-start=\"395\" data-end=\"437\"\u003e96% Annual Fuel Utilization Efficiency\u003c\/strong\u003e, this furnace converts nearly all the fuel into usable heat — leading to \u003cstrong data-start=\"511\" data-end=\"548\"\u003esignificantly lower heating costs\u003c\/strong\u003e compared to standard furnaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"oycnte\" data-start=\"581\" data-end=\"782\"\u003e\n\u003cp data-start=\"583\" data-end=\"782\"\u003e\u003cstrong data-start=\"583\" data-end=\"617\"\u003eVariable‑Speed Comfort Control\u003c\/strong\u003e\u003cbr data-start=\"617\" data-end=\"620\"\u003e• The \u003cstrong data-start=\"628\" data-end=\"659\"\u003evariable‑speed blower motor\u003c\/strong\u003e continuously adjusts airflow for \u003cstrong data-start=\"693\" data-end=\"781\"\u003esmooth temperature transitions, quieter operation, and better indoor air circulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18p95x\" data-start=\"784\" data-end=\"990\"\u003e\n\u003cp data-start=\"786\" data-end=\"990\"\u003e\u003cstrong data-start=\"786\" data-end=\"807\"\u003eTwo‑Stage Heating\u003c\/strong\u003e\u003cbr data-start=\"807\" data-end=\"810\"\u003e• \u003cstrong data-start=\"814\" data-end=\"837\"\u003eTwo‑stage gas valve\u003c\/strong\u003e enhances comfort by using a \u003cstrong data-start=\"866\" data-end=\"900\"\u003elow stage for moderate heating\u003c\/strong\u003e and a \u003cstrong data-start=\"907\" data-end=\"935\" data-is-only-node=\"\"\u003ehigh stage for cold days\u003c\/strong\u003e, reducing temperature swings and improving energy use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bxturf\" data-start=\"992\" data-end=\"1185\"\u003e\n\u003cp data-start=\"994\" data-end=\"1185\"\u003e\u003cstrong data-start=\"994\" data-end=\"1041\"\u003eFlexible Installation (Downflow\/Horizontal)\u003c\/strong\u003e\u003cbr data-start=\"1041\" data-end=\"1044\"\u003e• Designed for \u003cstrong data-start=\"1061\" data-end=\"1087\"\u003edownflow or horizontal\u003c\/strong\u003e setups — perfect for \u003cstrong data-start=\"1109\" data-end=\"1147\"\u003ebasements, attics, or crawl spaces\u003c\/strong\u003e where vertical upflow isn’t feasible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u3dgdr\" data-start=\"1187\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1189\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1208\"\u003e115 V Operation\u003c\/strong\u003e\u003cbr data-start=\"1208\" data-end=\"1211\"\u003e• Uses standard \u003cstrong data-start=\"1229\" data-end=\"1244\"\u003e115 V power\u003c\/strong\u003e, simplifying electrical needs and installation for existing home systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"onove7\" data-start=\"1320\" data-end=\"1519\"\u003e\n\u003cp data-start=\"1322\" data-end=\"1519\"\u003e\u003cstrong data-start=\"1322\" data-end=\"1353\"\u003eModern System Compatibility\u003c\/strong\u003e\u003cbr data-start=\"1353\" data-end=\"1356\"\u003e• When paired with a matched R‑32 HVAC outdoor unit and a \u003cstrong data-start=\"1416\" data-end=\"1436\"\u003esmart thermostat\u003c\/strong\u003e, this furnace helps deliver \u003cstrong data-start=\"1465\" data-end=\"1518\"\u003ebalanced comfort and enhanced seasonal efficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"263\" data-end=\"442\"\u003e\u003cstrong data-start=\"263\" data-end=\"318\"\u003eQ: What heating capacity does this furnace deliver?\u003c\/strong\u003e\u003cbr data-start=\"318\" data-end=\"321\"\u003eA: This unit provides \u003cstrong data-start=\"343\" data-end=\"371\"\u003e60,000 BTU of input heat\u003c\/strong\u003e and efficient output for \u003cstrong data-start=\"397\" data-end=\"441\"\u003esmall to medium homes and tighter spaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"444\" data-end=\"602\"\u003e\u003cstrong data-start=\"444\" data-end=\"486\"\u003eQ: How energy efficient is this model?\u003c\/strong\u003e\u003cbr data-start=\"486\" data-end=\"489\"\u003eA: With \u003cstrong data-start=\"497\" data-end=\"509\"\u003e96% AFUE\u003c\/strong\u003e, it converts \u003cstrong data-start=\"523\" data-end=\"555\"\u003e96% of fuel into usable heat\u003c\/strong\u003e, lowering gas bills and maximizing efficiency.\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"814\"\u003e\u003cstrong data-start=\"604\" data-end=\"656\"\u003eQ: What type of blower and staging does it have?\u003c\/strong\u003e\u003cbr data-start=\"656\" data-end=\"659\"\u003eA: It features a \u003cstrong data-start=\"676\" data-end=\"711\"\u003evariable‑speed ECM blower motor\u003c\/strong\u003e and \u003cstrong data-start=\"716\" data-end=\"739\"\u003etwo‑stage gas valve\u003c\/strong\u003e for \u003cstrong data-start=\"744\" data-end=\"813\"\u003econsistent comfort, quieter operation, and better airflow control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"816\" data-end=\"998\"\u003e\u003cstrong data-start=\"816\" data-end=\"870\"\u003eQ: What installation configurations are supported?\u003c\/strong\u003e\u003cbr data-start=\"870\" data-end=\"873\"\u003eA: Supports \u003cstrong data-start=\"885\" data-end=\"924\"\u003edownflow or horizontal installation\u003c\/strong\u003e, ideal for \u003cstrong data-start=\"936\" data-end=\"997\"\u003ecrawlspaces, attics, closets, or compact mechanical rooms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1000\" data-end=\"1171\"\u003e\u003cstrong data-start=\"1000\" data-end=\"1043\"\u003eQ: What power and fuel does it require?\u003c\/strong\u003e\u003cbr data-start=\"1043\" data-end=\"1046\"\u003eA: Runs on \u003cstrong data-start=\"1057\" data-end=\"1066\"\u003e115 V\u003c\/strong\u003e electrical supply and is \u003cstrong data-start=\"1092\" data-end=\"1123\"\u003efactory set for natural gas\u003c\/strong\u003e, with \u003cstrong data-start=\"1130\" data-end=\"1160\"\u003epropane convertible option\u003c\/strong\u003e available.\u003c\/p\u003e\n\u003cp data-start=\"1173\" data-end=\"1341\"\u003e\u003cstrong data-start=\"1173\" data-end=\"1220\"\u003eQ: Is this model environmentally compliant?\u003c\/strong\u003e\u003cbr data-start=\"1220\" data-end=\"1223\"\u003eA: Yes — designed with \u003cstrong data-start=\"1246\" data-end=\"1267\"\u003elow‑NOx emissions\u003c\/strong\u003e and \u003cstrong data-start=\"1272\" data-end=\"1302\"\u003ehigh combustion efficiency\u003c\/strong\u003e for environmentally sensitive regions.\u003c\/p\u003e\n\u003cp data-start=\"1343\" data-end=\"1542\"\u003e\u003cstrong data-start=\"1343\" data-end=\"1402\"\u003eQ: Does the furnace have smart diagnostics or controls?\u003c\/strong\u003e\u003cbr data-start=\"1402\" data-end=\"1405\"\u003eA: Integrated \u003cstrong data-start=\"1419\" data-end=\"1462\"\u003eComfortBridge™ communication technology\u003c\/strong\u003e enables advanced diagnostic capability and compatible smart thermostat control.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1tef5k2\" data-start=\"186\" data-end=\"317\"\u003e\n\u003cp data-start=\"188\" data-end=\"317\"\u003e\u003cstrong data-start=\"188\" data-end=\"220\"\u003eReplace or Clean Air Filters\u003c\/strong\u003e\u003cbr data-start=\"220\" data-end=\"223\"\u003eInspect \u003cstrong data-start=\"233\" data-end=\"244\"\u003emonthly\u003c\/strong\u003e; replace every \u003cstrong data-start=\"260\" data-end=\"274\" data-is-only-node=\"\"\u003e1–3 months\u003c\/strong\u003e to maintain airflow and high efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qn6ry6\" data-start=\"319\" data-end=\"470\"\u003e\n\u003cp data-start=\"321\" data-end=\"470\"\u003e\u003cstrong data-start=\"321\" data-end=\"358\"\u003eInspect Burner and Heat Exchanger\u003c\/strong\u003e\u003cbr data-start=\"358\" data-end=\"361\"\u003eSchedule \u003cstrong data-start=\"372\" data-end=\"406\"\u003eannual professional inspection\u003c\/strong\u003e to ensure safe operation and consistent 96% AFUE performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q8r5x6\" data-start=\"472\" data-end=\"615\"\u003e\n\u003cp data-start=\"474\" data-end=\"615\"\u003e\u003cstrong data-start=\"474\" data-end=\"507\"\u003eClean Blower and Fan Assembly\u003c\/strong\u003e\u003cbr data-start=\"507\" data-end=\"510\"\u003eDust buildup can reduce efficiency and airflow; professional cleaning is recommended \u003cstrong data-start=\"597\" data-end=\"612\"\u003eonce a year\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g7ak5t\" data-start=\"617\" data-end=\"719\"\u003e\n\u003cp data-start=\"619\" data-end=\"719\"\u003e\u003cstrong data-start=\"619\" data-end=\"649\"\u003eCheck Thermostat Operation\u003c\/strong\u003e\u003cbr data-start=\"649\" data-end=\"652\"\u003eConfirm proper calibration for smooth two-stage heating cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16z63xi\" data-start=\"721\" data-end=\"852\"\u003e\n\u003cp data-start=\"723\" data-end=\"852\"\u003e\u003cstrong data-start=\"723\" data-end=\"754\"\u003eMaintain Ductwork and Vents\u003c\/strong\u003e\u003cbr data-start=\"754\" data-end=\"757\"\u003eEnsure unobstructed airflow in downflow or horizontal configuration for consistent heating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nvqv0\" data-start=\"854\" data-end=\"987\"\u003e\n\u003cp data-start=\"856\" data-end=\"987\"\u003e\u003cstrong data-start=\"856\" data-end=\"890\"\u003eInspect Electrical Connections\u003c\/strong\u003e\u003cbr data-start=\"890\" data-end=\"893\"\u003eSecure wiring and have a technician check for corrosion or wear during annual maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b4bquc\" data-start=\"989\" data-end=\"1126\"\u003e\n\u003cp data-start=\"991\" data-end=\"1126\"\u003e\u003cstrong data-start=\"991\" data-end=\"1031\"\u003eSchedule Annual Professional Service\u003c\/strong\u003e\u003cbr data-start=\"1031\" data-end=\"1034\"\u003eVerify gas pressure, blower performance, and safety controls to extend furnace lifespan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533431504970,"sku":"GDVT960603BN","price":2025.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/90_downflow_frontright-800x800_1c60086e-9172-428e-8485-fdbabbdbf847.webp?v=1776875486","url":"https:\/\/wen0d6-q0.myshopify.com\/products\/goodman-60-000-btu-96-variable-speed-gas-furnace-17-5-width-downflow-horizontal-two-stage-115v-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}