{"product_id":"goodman-80-000-btu-80-gas-furnace-24-5-width-upflow-horizontal-two-stage-115v-r32","title":"Goodman - 80,000 BTU 80% Gas Furnace - 24.5\" Width - Upflow \/ Horizontal - Two Stage - 115V - R32 - GR9T800805DX","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 80,000 BTU 80% Gas Furnace - 24.5\" Width - Upflow \/ Horizontal - Two Stage - 115V - R32 - GR9T800805DX\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GR9T800805DX Goodman low NOx gas furnace features high-quality construction and efficient operation at a great value. The GR9T800805DX two-stage, 9-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the Goodman GR9T800805DX.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThis furnace is ideal to heat a medium-sized house (depending on climate)\u003c\/li\u003e\n\u003cli\u003e80,000 BTU 80% efficient natural gas furnace\u003c\/li\u003e\n\u003cli\u003eRequires metal flue venting\u003c\/li\u003e\n\u003cli\u003eCan be used in the upflow or horizontal orientation\u003c\/li\u003e\n\u003cli\u003eCan be converted to an LP furnace with a conversion kit (sold separately)\u003c\/li\u003e\n\u003cli\u003eInnovative design for electrical efficiency, safety, and lower sound output\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wa1i\" colspan=\"2\"\u003eGoodman 80% 80,000 BTU Two Stage Gas Furnace - 24.5\" Width - Upflow \/ Horizontal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGR9T800805DX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e129.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e215358031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eExhaust Flue Requirement\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eR-32 Compliant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eReplaces\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGM9C800805DX, GMEC800805DX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eProduct Features\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eLow NOx, New Refrigerant Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eFurnace Efficiency \/ AFUE\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeating BTU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBlower Motor\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e9 Speed - ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMaximum CFM\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow\/Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e115v 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMax Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eMin. Breaker Size\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e14.3 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLow NOx\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eLow NOx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBurner Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003ePropane, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e33 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e24.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GR9T80_GD9T80-Install-Manual.pdf?v=1759832887\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eInstallation Manual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GR9T80_Specification_Sheet.pdf?v=1759832884\" target=\"_blank\"\u003e\u003cstrong\u003eSpecifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"lm3prr\" data-start=\"27\" data-end=\"175\"\u003e\n\u003cp data-start=\"29\" data-end=\"175\"\u003e\u003cstrong data-start=\"29\" data-end=\"60\"\u003eReliable 80,000 BTU Output:\u003c\/strong\u003e Provides \u003cstrong data-start=\"70\" data-end=\"97\"\u003e80 k BTU with 80 % AFUE\u003c\/strong\u003e, delivering dependable heat for medium‑sized homes with consistent comfort.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1u3nxob\" data-start=\"176\" data-end=\"339\"\u003e\n\u003cp data-start=\"178\" data-end=\"339\"\u003e\u003cstrong data-start=\"178\" data-end=\"208\"\u003eTwo‑Stage Heating Comfort:\u003c\/strong\u003e \u003cstrong data-start=\"209\" data-end=\"232\"\u003eTwo‑stage gas valve\u003c\/strong\u003e adjusts output to match demand—reducing temperature swings and lowering noise versus single‑stage units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qozzar\" data-start=\"340\" data-end=\"517\"\u003e\n\u003cp data-start=\"342\" data-end=\"517\"\u003e\u003cstrong data-start=\"342\" data-end=\"380\"\u003eFlexible Upflow\/Horizontal Design:\u003c\/strong\u003e Designed for \u003cstrong data-start=\"394\" data-end=\"431\"\u003eupflow or horizontal installation\u003c\/strong\u003e, making it easier to fit in basements, closets, attics, or tight mechanical spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nkohez\" data-start=\"518\" data-end=\"655\"\u003e\n\u003cp data-start=\"520\" data-end=\"655\"\u003e\u003cstrong data-start=\"520\" data-end=\"545\"\u003eStandard 115 V Power:\u003c\/strong\u003e Runs on common \u003cstrong data-start=\"561\" data-end=\"592\"\u003e115‑volt electrical service\u003c\/strong\u003e, simplifying wiring and compatibility with existing systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bz97d8\" data-start=\"656\" data-end=\"797\"\u003e\n\u003cp data-start=\"658\" data-end=\"797\"\u003e\u003cstrong data-start=\"658\" data-end=\"681\"\u003eSolid Construction:\u003c\/strong\u003e \u003cstrong data-start=\"682\" data-end=\"716\"\u003eInsulated, heavy‑gauge cabinet\u003c\/strong\u003e increases durability, reduces heat loss, and helps maintain quieter operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l7vyyu\" data-start=\"798\" data-end=\"956\"\u003e\n\u003cp data-start=\"800\" data-end=\"956\"\u003e\u003cstrong data-start=\"800\" data-end=\"830\"\u003eService‑Friendly Features:\u003c\/strong\u003e Accessible panels and familiar layout make maintenance and servicing quicker and more straightforward for HVAC technicians.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xaakjy\" data-start=\"957\" data-end=\"1104\"\u003e\n\u003cp data-start=\"959\" data-end=\"1104\"\u003e\u003cstrong data-start=\"959\" data-end=\"985\"\u003eR‑32 Compliance Ready:\u003c\/strong\u003e Built to work with \u003cstrong data-start=\"1005\" data-end=\"1039\"\u003eR‑32 refrigerant‑based systems\u003c\/strong\u003e, ensuring compatibility with modern split HVAC configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"185\" data-end=\"470\"\u003e\u003cstrong data-start=\"185\" data-end=\"263\"\u003eQ: What heating capacity and efficiency does this Goodman furnace deliver?\u003c\/strong\u003e\u003cbr data-start=\"263\" data-end=\"266\"\u003eA: The \u003cstrong data-start=\"273\" data-end=\"297\"\u003eGoodman GR9T800805DX\u003c\/strong\u003e delivers \u003cstrong data-start=\"307\" data-end=\"321\"\u003e80,000 BTU\u003c\/strong\u003e input heat with \u003cstrong data-start=\"338\" data-end=\"361\"\u003e80% AFUE efficiency\u003c\/strong\u003e, providing dependable heat output suitable for \u003cstrong data-start=\"409\" data-end=\"431\"\u003emedium‑sized homes\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"472\" data-end=\"713\"\u003e\u003cstrong data-start=\"472\" data-end=\"519\"\u003eQ: What type of heating stages does it use?\u003c\/strong\u003e\u003cbr data-start=\"519\" data-end=\"522\"\u003eA: This model features a \u003cstrong data-start=\"547\" data-end=\"570\"\u003etwo‑stage gas valve\u003c\/strong\u003e, offering quieter operation and more consistent home temperature control compared to single‑stage units. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"715\" data-end=\"944\"\u003e\u003cstrong data-start=\"715\" data-end=\"769\"\u003eQ: What blower and motor does the furnace include?\u003c\/strong\u003e\u003cbr data-start=\"769\" data-end=\"772\"\u003eA: Equipped with a \u003cstrong data-start=\"791\" data-end=\"837\"\u003emulti‑speed ECM circulator motor (9‑speed)\u003c\/strong\u003e for optimized airflow, quieter performance, and improved efficiency. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"946\" data-end=\"1168\"\u003e\u003cstrong data-start=\"946\" data-end=\"998\"\u003eQ: What installation orientations are supported?\u003c\/strong\u003e\u003cbr data-start=\"998\" data-end=\"1001\"\u003eA: Designed for \u003cstrong data-start=\"1017\" data-end=\"1054\"\u003eupflow or horizontal (left\/right)\u003c\/strong\u003e installation, allowing flexible placement in closets, attics, or basements. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1170\" data-end=\"1413\"\u003e\u003cstrong data-start=\"1170\" data-end=\"1228\"\u003eQ: What electrical and fuel requirements does it have?\u003c\/strong\u003e\u003cbr data-start=\"1228\" data-end=\"1231\"\u003eA: Operates on \u003cstrong data-start=\"1246\" data-end=\"1274\"\u003e115 V single‑phase 60 Hz\u003c\/strong\u003e electrical service, with \u003cstrong data-start=\"1300\" data-end=\"1315\"\u003enatural gas\u003c\/strong\u003e and \u003cstrong data-start=\"1320\" data-end=\"1356\"\u003eLP propane conversion capability\u003c\/strong\u003e (with proper kit). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1415\" data-end=\"1578\"\u003e\u003cstrong data-start=\"1415\" data-end=\"1452\"\u003eQ: What venting type is required?\u003c\/strong\u003e\u003cbr data-start=\"1452\" data-end=\"1455\"\u003eA: As an \u003cstrong data-start=\"1464\" data-end=\"1484\"\u003e80% AFUE furnace\u003c\/strong\u003e, it uses \u003cstrong data-start=\"1494\" data-end=\"1516\"\u003emetal flue venting\u003c\/strong\u003e for combustion exhaust. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1580\" data-end=\"1773\"\u003e\u003cstrong data-start=\"1580\" data-end=\"1641\"\u003eQ: What are the physical dimensions and airflow capacity?\u003c\/strong\u003e\u003cbr data-start=\"1641\" data-end=\"1644\"\u003eA: Cabinet measures \u003cstrong data-start=\"1664\" data-end=\"1694\"\u003e24.5″ W × 28″ D × 33.38″ H\u003c\/strong\u003e with a maximum airflow of ~\u003cstrong data-start=\"1722\" data-end=\"1734\"\u003e2000 CFM\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1775\" data-end=\"2063\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1836\"\u003eQ: What durability and performance features are included?\u003c\/strong\u003e\u003cbr data-start=\"1836\" data-end=\"1839\"\u003eA: Includes \u003cstrong data-start=\"1851\" data-end=\"1896\"\u003eheavy‑gauge steel cabinet with insulation\u003c\/strong\u003e, \u003cstrong data-start=\"1898\" data-end=\"1937\"\u003eSilicon Nitride hot‑surface igniter\u003c\/strong\u003e, and \u003cstrong data-start=\"1943\" data-end=\"1976\"\u003eself‑diagnostic control board\u003c\/strong\u003e for reliable heating and simplified maintenance.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69afaf41-d0e0-8323-a3ce-642acad1b445-2\" data-testid=\"conversation-turn-28\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"260a4270-c0be-4d1f-a5cf-55c14cac346c\" dir=\"auto\" data-message-model-slug=\"gpt-5-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cul data-start=\"119\" data-end=\"1098\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1djnsnx\" data-start=\"119\" data-end=\"251\"\u003e\n\u003cp data-start=\"121\" data-end=\"251\"\u003e\u003cstrong data-start=\"121\" data-end=\"170\"\u003eReplace or clean air filters every 1–3 months\u003c\/strong\u003e to maintain airflow and prevent dust buildup on the heat exchanger and blower.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10qtrqu\" data-start=\"252\" data-end=\"359\"\u003e\n\u003cp data-start=\"254\" data-end=\"359\"\u003e\u003cstrong data-start=\"254\" data-end=\"293\"\u003eInspect the heat exchanger annually\u003c\/strong\u003e for cracks or corrosion to ensure safe and efficient operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bfxopk\" data-start=\"360\" data-end=\"453\"\u003e\n\u003cp data-start=\"362\" data-end=\"453\"\u003e\u003cstrong data-start=\"362\" data-end=\"416\"\u003eClean burners, pilot assembly, and ignition system\u003c\/strong\u003e for reliable two-stage combustion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1254v5x\" data-start=\"454\" data-end=\"542\"\u003e\n\u003cp data-start=\"456\" data-end=\"542\"\u003e\u003cstrong data-start=\"456\" data-end=\"499\"\u003eCheck the blower motor and fan assembly\u003c\/strong\u003e for dust, debris, and lubrication needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1166k52\" data-start=\"543\" data-end=\"650\"\u003e\n\u003cp data-start=\"545\" data-end=\"650\"\u003e\u003cstrong data-start=\"545\" data-end=\"578\"\u003eInspect venting and flue pipe\u003c\/strong\u003e for obstructions or leaks to ensure safe exhaust of combustion gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o4r5y0\" data-start=\"651\" data-end=\"745\"\u003e\n\u003cp data-start=\"653\" data-end=\"745\"\u003e\u003cstrong data-start=\"653\" data-end=\"709\"\u003eTest gas valves, two-stage operation, and thermostat\u003c\/strong\u003e for accurate temperature control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vay747\" data-start=\"746\" data-end=\"828\"\u003e\n\u003cp data-start=\"748\" data-end=\"828\"\u003e\u003cstrong data-start=\"748\" data-end=\"786\"\u003eVerify 115V electrical connections\u003c\/strong\u003e and check wiring for wear or corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2yw85n\" data-start=\"829\" data-end=\"909\"\u003e\n\u003cp data-start=\"831\" data-end=\"909\"\u003e\u003cstrong data-start=\"831\" data-end=\"862\"\u003eKeep surrounding area clear\u003c\/strong\u003e to maintain airflow and reduce fire hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ioe2q\" data-start=\"910\" data-end=\"1010\"\u003e\n\u003cp data-start=\"912\" data-end=\"1010\"\u003e\u003cstrong data-start=\"912\" data-end=\"957\"\u003eSchedule annual professional HVAC service\u003c\/strong\u003e for full inspection, cleaning, and safety testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1orv5b3\" data-start=\"1011\" data-end=\"1098\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"1013\" data-end=\"1098\" data-is-last-node=\"\"\u003e\u003cstrong data-start=\"1013\" data-end=\"1038\"\u003eRegister your furnace\u003c\/strong\u003e to activate warranty coverage and maintain service records.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":43533440548938,"sku":"GR9T800805DX","price":1200.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/2387\/2074\/files\/80_upflow_frontleft-800x800_12e8e5e4-6001-458a-a2e4-f75dcafc164a.webp?v=1776875927","url":"https:\/\/wen0d6-q0.myshopify.com\/products\/goodman-80-000-btu-80-gas-furnace-24-5-width-upflow-horizontal-two-stage-115v-r32","provider":"Power Gear for Every Journey","version":"1.0","type":"link"}