Ir directamente a la información del producto
1 de 10

Goodman - 1.5 Ton/18,000 BTU Air Conditioner Condenser - SEER2 15.2 - Single Stage - R32 - GLXS5BA1810

Goodman - 1.5 Ton/18,000 BTU Air Conditioner Condenser - SEER2 15.2 - Single Stage - R32 - GLXS5BA1810

Precio habitual $1,620.99 USD
Precio habitual $2,161.00 USD Precio de oferta $1,620.99 USD
Oferta Agotado

Descripción

Goodman - 1.5 Ton/18,000 BTU Air Conditioner Condenser - SEER2 15.2 - Single Stage - R32 - GLXS5BA1810

The Goodman 1.5 Ton 15.2 SEER2 Air Conditioner Condenser (R-32) - GLXS4BA1810 uses the environmentally friendly refrigerant R-32 and features the unique Goodman sound control top design for quiet operation. In addition, the unit has an attractive louvered metal guard that protects the coil from damage plus a powder-paint finish that provides premium durability and improved UV protection.

Features
  • Energy-efficient compressor
  • Fully charged for 15' of tubing length
  • Copper tube/ enhanced aluminum fin coil-5mm diameter
  • Factory-installed filter drier
  • Sweat connection service valves with easy access to gauge ports
  • Enclosed contactor
  • High-pressure switch
  • Ground lug connection
  • Capacitors with extended life
  • ETL Listed
Specifications
Model Number(s) GLXS5BA1810
Brand Goodman
Type Air Conditioning
Category Condensers
Ton 1.5 Ton
SEER 15.2
Cooling Stage(s) 1
Compressor Stage Single
Voltage 208/230V
Refrigerant Type R-32
UPC # 663051735460
Manual
What our Experts Think
  • Perfect for Smaller Spaces: Provides 18,000 BTU cooling capacity, making it an excellent fit for small homes, apartments, or dedicated cooling zones.

  • High Efficiency: 15.2 SEER2 rating delivers superior energy performance, helping reduce cooling costs compared to lower‑SEER models.

  • Dependable Single‑Stage Operation: Single‑stage compressor offers simple, reliable performance with fewer moving parts and easier maintenance.

  • R‑32 Refrigerant Compatible: Uses modern R‑32 refrigerant for improved heat transfer efficiency and lower environmental impact versus older refrigerants.

  • Weather‑Resistant Build: Durable outdoor cabinet stands up to weather and seasonal conditions, enhancing long‑term reliability.

  • Service‑Friendly Design: Accessible service valves and panels simplify installation and future maintenance work.


Q&A

Q: What cooling capacity and efficiency does the Goodman GLXS5BA1810 1.5 Ton Air Conditioner Condenser deliver?
A: This condenser offers 1.5 tons (≈18,000 BTU) of cooling with a 15.2 SEER2 efficiency rating, balancing solid energy performance and comfort for small to medium residential spaces.

Q: What type of compressor and refrigerant does it use?
A: It uses a single‑stage scroll compressor and is designed for R‑32 refrigerant, which supports modern efficiency and lower environmental impact.

Q: What are the main durability and protection features?
A: Standard features include a factory‑installed filter drier, enclosed contactor, high‑pressure safety switch, extended‑life capacitors, and a galvanized, powder‑coated steel cabinet with coil guard for outdoor durability.

Q: What are the electrical and connection specifications?
A: The condenser operates on 208/230 V single‑phase power, with 3/8″ liquid and 3/4″ suction line connections, and comes pre‑charged for up to 15 ft of tubing to simplify installation.

Q: How loud is the unit in operation?
A: Typical sound levels are around 72–73 dBA, making it reasonably quiet for a residential outdoor unit.


Maintenance Tips
  • Maintain at least 24 inches of clearance around the outdoor unit for proper airflow and efficient cooling.

  • Clean the condenser coil regularly with low-pressure water to remove dirt and debris and maintain SEER2 15.2 efficiency.

  • Replace or clean indoor air filters every 1–3 months to reduce strain on the compressor and maintain airflow.

  • Inspect refrigerant lines and insulation for leaks, damage, or loose connections to ensure proper R‑32 operation.

  • Check electrical connections and disconnect box for corrosion, wear, or loose wiring.

  • Monitor unusual noises or vibrations from the compressor or fan motor as early signs of maintenance needs.

  • Ensure the unit is level to prevent drainage issues and uneven cooling.

  • Keep the cabinet and coil guards clean and intact to protect components and maintain airflow.

  • Schedule annual professional HVAC service to inspect refrigerant levels, coils, and system controls.

Ver todos los detalles