Ir directamente a la información del producto
1 de 10

Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630B3

Goodman - 2.5 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630B3

Precio habitual $3,435.99 USD
Precio habitual $4,580.00 USD Precio de oferta $3,435.99 USD
Oferta Agotado

Descripción

Features
  • This furnace is ideal to heat a smaller house (depending on climate)
  • 40,000 BTU 96% efficient natural gas furnace
  • Requires plastic/PVC flue venting
  • Complies with Clean Air Act New Refrigerant Requirements
  • Can be used in the downflow or horizontal orientation
  • Can be converted to an LP furnace with a conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
  • Ideal size to cover a small house in ideal climates
  • 2.5 ton, 14.3 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Fully charged for up to 15' of line set
  • Low sound output
  • Factory-installed filter drier
  • 3 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
Specifications
2.5 Ton 14.3 SEER2 Goodman Air Conditioner Condenser - R32
SKU GLXS4BA3010
Weight 170.000000
Manufacturer Goodman
Replaces GSXN403010
Product Features New Refrigerant Compliant
Cooling BTU 30,000
Decibel Level (dBA) 71
Horsepower 1/6 HP
Refrigerant R32
SEER2 14.3
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 25 Amps
Min. Breaker Size 15.0 Amps
Tonnage 2.5 Ton
Connection Sweat
Height 32"
Width 29"
Depth 29"
Manual
What our Experts Think
  • Balanced Year‑Round Comfort: The Goodman CHPTA3630B3 HVAC System matches a 96% AFUE gas furnace with a 2.5 ton (40,000 BTU) air conditioner, delivering efficient heating and cooling in one system.

  • High‑Efficiency Heating: The 96% AFUE furnace helps maximize fuel use, reducing winter heating costs with reliable warmth.

  • Energy‑Smart Cooling: With 14.5 SEER2, the air conditioner provides improved cooling efficiency, lowering energy consumption during hot months.

  • Horizontal Installation Fit: Designed for horizontal duct applications, ideal for tight spaces such as crawlspaces, attics, or compact mechanical areas.

  • R32 Refrigerant Performance: Uses R32 refrigerant for better heat transfer and lower environmental impact than older refrigerants.

  • Matched System Advantage: Engineered as a coordinated package to ensure optimized airflow, capacity balance, and dependable year‑round performance.

  • Goodman Value & Reliability: Combines high heating efficiency, efficient cooling, and flexible installation, making it a smart choice for homeowners wanting dependable, whole‑home comfort.


Q&A

Q: What components are included in this system?
A: This complete HVAC system includes: a 2.5 ton 14.5 SEER2 R32 air conditioner condenser, a 40,000 BTU 96% AFUE gas furnace, and a horizontal cased evaporator coil (CHPTA3630B3) — all matched for performance.

Q: What heating and cooling capacities does it offer?
A: Cooling capacity is 2.5 tons (~30,000 BTU) with 14.5 SEER2 efficiency for efficient cooling. The furnace delivers 40,000 BTU heat input at 96% AFUE, meaning most fuel becomes usable heat.

Q: What does a 96% AFUE rating mean?
A: 96% AFUE means approximately 96 ¢ of every dollar spent on fuel becomes heat, making this one of the most efficient gas furnaces available for operating cost savings.

Q: What is SEER2 14.5 and why it matters?
A: SEER2 14.5 measures seasonal cooling efficiency under updated test standards. A higher SEER2 rating improves efficiency and typically reduces electricity costs compared to lower SEER units.

Q: What installation configurations are supported?
A: The furnace and coil support horizontal installation, ideal for attics, closets, or tight mechanical spaces with horizontal duct runs.

Q: What refrigerant does the system use?
A: This system uses R32 refrigerant, a newer and more environmentally friendly choice that meets updated regulatory requirements.


Maintenance Tips
  • Replace Air Filters Monthly: Keep airflow optimal and protect both furnace and AC components; replace every 1–3 months.

  • Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.

  • Inspect Furnace Venting: Check intake and exhaust pipes for blockages or damage to maintain safe operation.

  • Clean Around the Units: Maintain 2–3 ft clearance around furnace and condenser to prevent dust buildup and allow proper airflow.

  • Check Thermostat & Electricals: Verify thermostat settings, gas supply, and 115V/208–230V circuits for proper operation.

  • Monitor System Performance: Listen for unusual noises from the variable-speed blower or condenser; watch for reduced heating or cooling efficiency.

  • Schedule Annual Professional Service: Licensed HVAC technicians should inspect burners, heat exchanger, gas pressure, AC refrigerant charge, and safety controls yearly.

Ver todos los detalles