Features
  • Ideal size to cover a small house in ideal climates
  • 2.5 ton, 14.3 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Fully charged for up to 15' of line set
  • Low sound output
  • Factory-installed filter drier
  • 3 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
  • This furnace is ideal to heat a smaller house (depending on climate)
  • 40,000 BTU 96% AFUE natural gas furnace
  • Requires plastic/PVC flue venting
  • Complies with Clean Air Act New Refrigerant Requirements
  • Can be used in the downflow or horizontal orientation
  • Can be converted to an LP furnace with an optional conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
SKU GLXS4BA3010
Weight 170.000000
Manufacturer Goodman
Replaces GSXN403010
Product Features New Refrigerant Compliant
Cooling BTU 30,000
Decibel Level (dBA) 71
Horsepower 1/6 HP
Refrigerant R32
SEER2 14.3
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 25 Amps
Min. Breaker Size 15.0 Amps
Tonnage 2.5 Ton
Connection Sweat
Height 32"
Width 29"
Depth 29"
Owner's Manual
What our Experts Think
  • Well‑rounded cooling + high‑efficiency heating: This system combines a 2.5 ton R‑32 air conditioner (~14.5 SEER2) with a 96 % AFUE, 60,000 BTU gas furnace, offering efficient year‑round comfort for small to medium homes.

  • Lower energy bills in winter: The 96 % AFUE furnace converts most fuel into heat—only ~4 % is lost—helping reduce heating costs compared to standard 80 % AFUE units.

  • Stable, smooth airflow: The furnace’s multi‑speed ECM blower motor delivers controlled airflow with quieter operation and more consistent indoor temperatures than basic single‑speed motors.

  • Modern refrigerant and cooling tech: The GLXS4BA3010 condenser uses R‑32 refrigerant for improved thermodynamic efficiency and a factory‑installed TXV evaporator coil helps with better humidity control and cooling responsiveness.

  • Versatile installation options: Designed for horizontal placement and multi‑position setups, this system fits attics, crawlspaces, and other tight mechanical areas with installation flexibility.

  • Built‑in durability: Goodman components feature heavy‑gauge cabinets, insulated panels, and extended warranty options that support long‑term reliability and easier service access.

  • Cost‑effective comfort package: Our experts view this configuration as a solid mid‑efficiency HVAC solution that balances good seasonal efficiency, modern refrigerant tech, and dependable performance at an attractive value.


Q&A

Q: What type of HVAC system is this?
A: This is a complete high-efficiency Goodman 2.5-ton system, including a 14.5 SEER2 air conditioner (GLXS4BA3010), 2.5-ton cased evaporator coil (CHPTA3630B3), and 40,000 BTU 96% AFUE gas furnace (GD9T960403BN) for dependable year-round comfort.

Q: What size home is suitable for this system?
A: A 2.5-ton AC system (30,000 BTU) is ideal for medium-sized homes around 1,200–1,600 sq. ft., depending on insulation, ceiling height, and layout.

Q: How energy efficient is this system?
A: The system delivers 14.5 SEER2 cooling efficiency and a 96% AFUE gas furnace, converting nearly all fuel into usable heat for highly efficient residential heating.

Q: What refrigerant does the air conditioner use?
A: The outdoor condenser uses R‑32 refrigerant, a modern, eco-friendly refrigerant designed to maximize energy efficiency and reduce environmental impact.

Q: Does the furnace include advanced features?
A: Yes. The GD9T960403BN furnace has a variable-speed ECM blower motor, providing quieter operation, improved airflow, and consistent indoor temperatures.

Q: Can this system be installed horizontally?
A: Yes. Both the furnace and coil support horizontal installation, making it suitable for attics, crawl spaces, or closets where vertical space is limited.

Q: What components are included?
A: The package includes:

  • GLXS4BA3010 – 2.5 Ton 14.5 SEER2 outdoor AC condenser

  • CHPTA3630B3 – 2.5 Ton cased evaporator coil

  • GD9T960403BN – 40,000 BTU 96% AFUE gas furnace


Maintenance Tips
  • Replace air filters every 1–3 months: Maintains airflow, protects the blower motor, and improves indoor air quality.

  • Keep the outdoor condenser clear: Maintain 2–3 ft clearance around the unit and remove leaves, dirt, or debris to ensure optimal cooling performance.

  • Inspect evaporator coil and drain pan: Check the CHPTA aluminum coil for dust or clogs to prevent water leaks and maintain efficiency.

  • Check refrigerant line insulation: Ensure suction line insulation is intact to prevent energy loss.

  • Keep vents and registers unobstructed: Ensures balanced airflow for consistent heating and cooling throughout the home.

  • Schedule annual professional service: A certified HVAC technician should inspect the furnace heat exchanger, blower motor, refrigerant levels, and safety controls yearly.

  • Maintain a clear furnace area: Keep the surrounding space free of clutter for safe operation and proper airflow.