Features
  • Ideal size to cover a small house in ideal climates
  • 2 ton, 14.3 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Fully charged for up to 15' of line set
  • Low sound output
  • Factory-installed filter drier
  • 2.5 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
  • This furnace is ideal to heat a medium house (depending on climate)
  • 60,000 BTU 96% efficient natural gas furnace
  • Requires plastic/pvc flue venting
  • Can be used in the downflow or horizontal orientation
  • Can be converted to an LP furnace with a conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
SKU GLXS4BA2410
Weight 132.000000
Manufacturer Goodman
Replaces GSXN402410
Product Features New Refrigerant Compliant
Cooling BTU 24,000
Decibel Level (dBA) 74
Horsepower 1/8 HP
Refrigerant R32
SEER2 14.3
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 15 Amps
Min. Breaker Size 10.9 Amps
Tonnage 2 Ton
Connection Sweat
Height 27"
Width 26"
Depth 26"
Warranty 10 Years Parts with Online Registration
Owner's Manual
What our Experts Think
  • Balanced heating + cooling performance: This complete 2 ton (24,000 BTU) R‑32 split system combines a ~14.5 SEER2 air conditioner with a 96 % AFUE 60,000 BTU gas furnace, delivering dependable year‑round comfort for small to medium homes.

  • Very high heating efficiency: With 96 % AFUE, nearly all fuel converts to usable heat, reducing winter energy costs and boosting overall system efficiency compared with standard 80 % furnaces.

  • Modern condenser technology: The GLXS4BA2410 outdoor unit uses R‑32 refrigerant, which improves cooling efficiency and lowers global warming potential versus older refrigerants, helping future‑proof your installation.

  • Precise refrigerant control: The included CHPTA3026B3 evaporator coil with TXV enhances cooling responsiveness and humidity management by adjusting refrigerant flow based on load demands.

  • 9‑speed ECM blower: The GC9S960603BN furnace’s multi‑speed ECM motor boosts airflow control, reduces electrical draw, and runs more quietly than older PSC motors — contributing to smoother fan performance and fewer comfort swings.

  • Flexible installation: Designed for horizontal or downflow applications, this system easily fits attics, crawl spaces, and tight utility rooms where vertical setups aren’t possible.

  • Durable and service‑ready: Goodman’s condensing units and furnace cabinets are AHRI‑certified and ETL‑listed for safety, with features like robust steel construction and self‑diagnostic controls that simplify maintenance.

  • Strong value choice: Experts consider this a well‑rounded mid‑efficiency HVAC package — it blends solid cooling performance, excellent heating efficiency, modern refrigerant tech, and dependable components at a competitive price point.



Q&A

Q: What type of HVAC system is this?
A: This is a complete high-efficiency Goodman HVAC system, including a 2‑ton air conditioner (GLXS4BA2410), cased evaporator coil (CHPTA3026B3), and 60,000 BTU 96% AFUE gas furnace (GC9S960603BN) for year-round heating and cooling.

Q: What size home is this system suitable for?
A: A 2‑ton AC system (24,000 BTU cooling) is ideal for small to medium homes around 900–1,400 sq. ft., depending on insulation, climate, and home layout.

Q: How energy efficient is this system?
A: The system delivers 14.5 SEER2 cooling efficiency and a 96% AFUE gas furnace, meaning nearly all fuel is converted into usable heat for highly efficient residential comfort.

Q: What refrigerant does the air conditioner use?
A: The condenser uses R‑32 refrigerant, a modern, eco-friendly refrigerant that improves efficiency and reduces environmental impact.

Q: Does the furnace include advanced technology?
A: Yes. The GC9S960603BN furnace features a variable-speed ECM blower motor and a high-efficiency design for quiet operation, consistent airflow, and precise indoor temperature control.

Q: Can this system be installed horizontally?
A: Yes. The furnace and coil support horizontal airflow installation, making it suitable for attics, crawl spaces, or closets with limited vertical space.

Q: What components are included in this HVAC system?
A: The system includes:

  • GLXS4BA2410 – 2 Ton 14.5 SEER2 outdoor AC condenser

  • CHPTA3026B3 – 2 Ton cased evaporator coil

  • GC9S960603BN – 60,000 BTU 96% AFUE gas furnace


Maintenance Tips
  • Replace air filters every 1–3 months: Keeps airflow optimal, protects the blower motor, and improves indoor air quality.

  • Keep the outdoor condenser clean: Maintain 2–3 ft clearance and remove leaves, dirt, or debris for efficient cooling.

  • Inspect evaporator coil and condensate pan: The CHPTA coil should be checked for dust and clogs to prevent leaks and maintain cooling efficiency.

  • Check refrigerant line insulation: Ensure suction line insulation is intact to prevent energy loss.

  • Maintain clear vents and registers: Unblocked supply and return vents allow balanced airflow throughout the home.

  • Schedule annual professional service: A certified HVAC technician should inspect the furnace heat exchanger, blower motor, refrigerant levels, and safety controls yearly.

  • Keep the furnace area clean: Ensure surrounding space is clear for safe operation of the 96% AFUE gas furnace.