Ir directamente a la información del producto
1 de 10

Goodman - 2 Ton/80,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - CHPTA2426B3

Goodman - 2 Ton/80,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - CHPTA2426B3

Precio habitual $3,543.99 USD
Precio habitual $4,725.00 USD Precio de oferta $3,543.99 USD
Oferta Agotado

Descripción

Features
  • This furnace is ideal to heat a smaller house (depending on climate)
  • 80,000 BTU 96% efficient natural gas furnace
  • Requires plastic/PVC flue venting
  • Complies with Clean Air Act New Refrigerant Requirements
  • Can be used in the upflow or horizontal orientation
  • Can be converted to an LP furnace with a conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
  • Ideal size to cover a small house in ideal climates
  • 2 ton, 14.3 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Fully charged for up to 15' of line set
  • Low sound output
  • Factory-installed filter drier
  • 2 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
Specifications
80,000 BTU 96% AFUE 9-Speed Single Stage Goodman Gas Furnace - Upflow/Horizontal
SKU GR9S960803BN
Weight 118.000000
AHRI Certificate Number 215224973
Config Search Upflow/Horizontal
Exhaust Flue Requirement Plastic / PVC
Manufacturer Goodman
Product Features New Refrigerant Compliant
Furnace Efficiency / AFUE 96%
Heating BTU 80,000
Blower Motor 9 Speed - ECM
Maximum CFM 1200
Horsepower 1/2 HP
Configuration Upflow/Horizontal
Energy Star Yes
Electrical 115 V. 1 Phase 60 Hz
Max Breaker Size 15 Amps
Min. Breaker Size 10.1 Amps
Burner Stages Single
Fuel Type Propane, Natural Gas
Height 34.5"
Width 17.5"
Depth 28.75"
Manual
What our Experts Think
  • Complete Comfort System – Combines a **2 ton air conditioner with an 80,000 BTU, 96% AFUE gas furnace to deliver efficient year‑round cooling and heating for small to medium homes.

  • High Heating Efficiency (96% AFUE) – Maximizes fuel‑to‑heat conversion to lower winter heating costs compared with standard‑efficiency units.

  • 14.3 SEER2 Cooling Performance – Meets modern efficiency guidelines, helping reduce cooling energy use and provide comfortable indoor temperatures.

  • Horizontal Configuration – Designed for attic or crawl‑space installations, offering flexible placement in common residential layouts.

  • R‑32 Refrigerant Compatibility – Built for next‑generation, environmentally improved refrigerant, aligning with modern HVAC standards.

  • Multi‑Speed ECM Blower Motor – Provides quieter airflow, improved comfort, and better temperature distribution compared to basic blower motors.

  • Factory‑Matched Components – Engineered to work together for optimized system performance, reliability, and longevity when installed professionally.

  • Durable Construction & Support – Built with quality materials and backed by Goodman’s parts network for dependable long‑term use.


Q&A

Q: What components are included in this system?
A: This matched HVAC package includes a Goodman 2 ton 14.3 SEER2 R32 air conditioner condenser, a horizontal evaporator coil (CHPTA2426B3) with factory‑installed TXV, and a 96% AFUE 80,000 BTU gas furnace — all designed to work together for year‑round comfort.

Q: What heating and cooling capacity does it offer?
A: The 2 ton air conditioner cools spaces up to roughly 1,000–1,800 sq ft (varies with home size and climate), while the 80,000 BTU furnace delivers high‑efficiency heating for medium‑sized areas.

Q: What does 14.3 SEER2 mean?
A: 14.3 SEER2 is the seasonal energy efficiency rating for the AC, which helps lower cooling energy use and electricity costs compared to older, lower‑SEER systems.

Q: What does 96% AFUE mean for the furnace?
A: 96% AFUE means 96% of fuel is converted into heat, delivering high heating efficiency and reduced natural gas costs versus less efficient units.

Q: What are the benefits of the horizontal CHPTA2426B3 coil?
A: The CHPTA2426B3 coil is optimized for R32 refrigerant, with an all‑aluminum design and factory‑installed TXV for precise refrigerant control and efficient performance.

Q: How does the furnace perform?
A: The 96% AFUE gas furnace features a multi‑speed ECM blower, aluminized steel heat exchanger, and reliable two‑stage operation to balance performance and comfort.

Q: What refrigerant does the system use?
A: This system uses R32 refrigerant, which improves energy efficiency and has a lower environmental impact than many older refrigerants.


Maintenance Tips
  • Replace Air Filters Every 1–3 Months: Keeps airflow optimal, protects both furnace and AC components, and maintains efficiency.

  • Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.

  • Clean Outdoor AC Condenser: Rinse coils every 3–6 months to preserve SEER2 performance and prevent debris buildup.

  • Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe furnace operation.

  • Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 efficiency.

  • Maintain Condensate Drains: Keep furnace and AC drain lines clear to prevent water buildup or system shutdowns.

  • Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.

  • Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require prompt professional attention.

Ver todos los detalles