Goodman - 4 Ton/48,000 BTU - Multi-Positional - Heat Pump Split System - 15.2 SEER2 - R32 - GLZS5BA4810 

The Goodman Heat Pump Split System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, the Goodman Heat Pump Split System is a perfect choice for all of your heating and cooling needs.

Features
  • Designed to cover a smaller house in average climates
  • 4 Ton, 15.2 SEER2 heat pump condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Low sound output
  • Fully charged for up to 15' of line set
  • Factory-installed bi-flow filter drier
  • Air Handler
  • 4 ton air handler
  • Electric heat compatible
  • Optimized for use with R-32 refrigerant
  • Multi-speed, direct drive ECM blower motor
  • Multi-positional (upflow, downflow, or horizontal)
Specifications
4 Ton 15.2 SEER2 High Efficiency Goodman Heat Pump - 7.8 HSPF2
SKU GLZS5BA4810
Weight 292.000000
Manufacturer Goodman
Replaces GSZ160481
Cooling BTU 48,000
Heating BTU 48,000
Blower Motor Single Speed Motor
Decibel Level (dBA) 74
Horsepower 0.25 HP
Refrigerant R32
SEER2 15.2
Condenser Stages Single Stage
Compressor Type Scroll
Liquid Line 3/8"
Suction Line 1 1/8"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 45 Amps
Min. Breaker Size 26.2 Amps
Tonnage 4 Ton
Connection Sweat
Height 36 1/2"
Width 35 1/2"
Depth 35 1/2"
Manual
What our Experts Think
  • Efficient Year‑Round Comfort with Modern R‑32 Refrigerant
    The Goodman GLZS5BA4810 4 Ton Heat Pump uses R‑32 refrigerant, delivering 48,000 BTU cooling and heating capacity with a 15.2 SEER2 rating for balanced energy performance throughout the seasons.

  • Reliable Single‑Stage Scroll Compressor
    A single‑stage scroll compressor offers dependable, consistent performance with fewer moving parts—helping reduce service complexity and support long‑term reliability.

  • SmartShift® Defrost System for Quiet Heating
    Built‑in SmartShift® technology ensures smooth, quiet defrost cycles in heating mode, which enhances comfort without frequent noise disruptions.

  • Durable Outdoor Construction
    Heavy‑gauge galvanized‑steel cabinet with powder‑painted finish and steel louver coil guard protects against weather and corrosion, supporting longevity in outdoor installations.

  • Installer Friendly Features
    Factory‑installed accumulator, crankcase heater, high‑capacity muffler, and easy‑access service valves simplify installation and maintenance for HVAC professionals.

  • Quiet Operation & Certified Performance
    With around 73–74 dB noise level and AHRI/ETL certification, this unit is engineered for quieter operation while meeting industry performance standards.


Q&A

Q1: What type of HVAC system is this?
A: The Goodman GLZS5BA4810 is a 4 ton (48,000 BTU) heat pump split system designed for both heating and cooling in residential applications. It includes an outdoor heat pump condenser (must be paired with a compatible indoor air handler or coil).

Q2: What efficiency ratings does it have?
A: It delivers 15.2 SEER2 cooling efficiency and approximately 8.2 HSPF2 heating performance, providing balanced year‑round comfort and energy savings.

Q3: What refrigerant does this heat pump use?
A: The unit uses environmentally friendly R‑32 refrigerant, which helps improve efficiency and reduce environmental impact vs older refrigerants.

Q4: What kind of compressor and operation does it have?
A: It features a single‑stage scroll compressor for reliable, consistent performance throughout heating and cooling cycles.

Q5: What are the key durability features?
A: The heat pump has a heavy‑gauge galvanized steel cabinet, removable grille top, steel coil guard, extended‑life capacitor, factory‑installed accumulator and crankcase heater, and is AHRI certified and ETL listed for performance and safety.

Q6: How loud is the unit?
A: Typical sound levels are around the mid‑70 dB range during operation, offering reasonable outdoor noise control.

Q7: What installation flexibility does it offer?
A: When paired with a multi‑positional compatible indoor air handler, this system supports upflow, downflow, or horizontal installations for versatile home layouts.

Maintenance Tips
  • Replace Air Filters Every 1–3 Months – Clean filters protect the indoor coil and blower, maintaining proper airflow and system efficiency.

  • Clean Evaporator & Condenser Coils Annually – Dust and debris on all‑aluminum coils reduce heat transfer and SEER2 efficiency.

  • Inspect Refrigerant Lines & TXV – Ensure R32 refrigerant lines are leak-free and the thermostatic expansion valve regulates refrigerant correctly for efficient cooling/heating.

  • Maintain Proper Airflow – Keep supply and return vents clear and ensure blower fans operate without obstruction for optimal performance.

  • Check Condensate Drain & Pan – Prevent water buildup and microbial growth by keeping the condensate drain clear.

  • Inspect Electrical Components – Regularly check contactors, capacitors, and wiring for wear or corrosion to prevent failures.

  • Schedule Professional Annual Maintenance – Technicians should check refrigerant levels, clean coils, verify SEER2 performance, and ensure safe multi-positional heat pump operation.

Ver todos los detalles