Ir directamente a la información del producto
1 de 10

Goodman - 80,000 BTU 96% Gas Furnace - 17.5" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T960803BN

Goodman - 80,000 BTU 96% Gas Furnace - 17.5" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T960803BN

Precio habitual $1,759.99 USD
Precio habitual $2,346.00 USD Precio de oferta $1,759.99 USD
Oferta Agotado

Descripción

Goodman - 80,000 BTU 96% Gas Furnace - 17.5" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T960803BN

As a high-efficiency system, the GR9T960803BN Goodman gas furnace features many money saving features. The two-stage, 9-speed furnace uses a superior heat exchanger for better heat transfers to your home. Considered one of the best efficiencies on the market, the GR9T960803BN is a good way to go if you want to lower your gas bill.

Features
  • This furnace is ideal to heat a medium-sized house (depending on climate)
  • 80,000 BTU 96% AFUE natural gas furnace
  • Requires plastic/PVC flue venting
  • Complies with Clean Air Act New Refrigerant Requirements
  • Can be used in the upflow or horizontal orientation
  • Can be converted to an LP furnace with an optional conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
Goodman 96% 80,000 BTU Two Stage Gas Furnace - 17.5" Width - Upflow / Horizontal
SKU GR9T960803BN
Weight (in lbs) 118.000000
AHRI Certificate Number 215225027
Airflow Direction Upflow/Horizontal
Exhaust Flue Requirement Plastic / PVC
R-32 Compliant Yes
Brand/Manufacturer Goodman
Product Features New Refrigerant Compliant
Furnace Efficiency / AFUE 96%
Heating BTU 80,000
Blower Motor 9 Speed - ECM
Maximum CFM 1200
Configuration Upflow/Horizontal
Energy Star Yes
Electrical 115 V. 1 Phase 60 Hz
Max Breaker Size 15 Amps
Min. Breaker Size 7.8 Amps
Burner Stages Two
Fuel Type Propane, Natural Gas
Height 34.5"
Width 17.5"
Depth 28.75"
Manual

What our Experts Think
  • High‑Efficiency Heating: With a 96 % AFUE rating, this furnace converts most fuel into usable heat—reducing gas costs and energy waste compared with standard 80 % models.

  • Appropriate 80 k BTU Capacity: 80,000 BTU input makes it well‑suited for medium‑sized homes or larger living spaces needing consistent, robust heating output.

  • Two‑Stage Comfort: The two‑stage gas valve allows quieter, more stable temperature delivery by running at a lower stage for mild weather and full capacity when demand rises.

  • Multi‑Speed ECM Blower: 9‑speed ECM blower motor improves airflow control, enhances comfort distribution, lowers electricity use, and reduces operational noise.

  • Flexible Installation Options: Designed for upflow or horizontal orientation, offering flexibility in tight mechanical spaces like basements, closets, or attics.

  • Durable & Advanced Controls: Features heavy‑gauge steel construction, stainless secondary heat exchanger, silicon nitride igniter, and self‑diagnostic controls for reliable long‑term operation.

  • Low NOx & R‑32 Compliance: Meets Low NOx emissions standards and is designed for compatibility with R‑32 refrigerant systems, aligning with modern environmental requirements.

Q&A

Q: What heating capacity and efficiency does the Goodman GR9S960803BN furnace deliver?
A: The Goodman GR9S960803BN provides 80,000 BTU input heat with 96% AFUE efficiency, meaning most fuel is converted into usable heat for dependable home comfort.

Q: What type of operation and stages does it have?
A: This model features a single‑stage gas valve with a multi‑speed (9‑speed) ECM blower motor for quieter, efficient airflow and consistent temperature.

Q: What installation orientations are supported?
A: Designed for upflow or horizontal (left/right) installation, offering flexible placement in attics, basements, or other indoor spaces.

Q: What electrical and venting requirements does it have?
A: Operates on 115 V single‑phase power and, as a high‑efficiency furnace, requires plastic/PVC flue venting.

Q: What materials and durability features are included?
A: Features include heavy‑gauge steel cabinet, aluminized and secondary stainless‑steel heat exchangers, durable silicon nitride igniter, and self‑diagnostic control board, for long‑term reliability and easier service.

Q: What fuel types are supported?
A: Factory‑configured for natural gas but can be converted to LP propane with the appropriate conversion kit (sold separately).

Q: What are the physical dimensions and airflow capacity?
A: Measures about 34.5″ H × 17.5″ W × 28.75″ D with a maximum airflow ~1200 CFM, fitting common residential duct systems.


Maintenance Tips
  • Replace or clean air filters every 1–3 months to maintain airflow and prevent dust buildup on the heat exchanger and blower.

  • Inspect the heat exchanger annually for cracks or corrosion to ensure safe and efficient operation.

  • Clean burners, pilot assembly, and ignition system for reliable two-stage combustion.

  • Check the blower motor and fan assembly for dust, debris, and lubrication needs.

  • Inspect venting and flue pipe for obstructions or leaks to ensure safe exhaust of combustion gases.

  • Test gas valves, two-stage operation, and thermostat for accurate temperature control.

  • Verify 115V electrical connections and inspect wiring for wear or corrosion.

  • Keep surrounding area clear to maintain airflow and reduce fire hazards.

  • Schedule annual professional HVAC service for full inspection, cleaning, and safety testing.

Ver todos los detalles