Skip to product information
1 of 10

Goodman - 2 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - GLXS4BA2410 / CHPTA2426B3 / GD9T960403BN

Goodman - 2 Ton/40,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - GLXS4BA2410 / CHPTA2426B3 / GD9T960403BN

Regular price $3,593.99 USD
Regular price $4,791.00 USD Sale price $3,593.99 USD
Sale Sold out

Description

Features
  • Ideal size to cover a small house in ideal climates
  • 2 ton, 14.3 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Fully charged for up to 15' of line set
  • Low sound output
  • Factory-installed filter drier
  • 2 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
  • This furnace is ideal to heat a smaller house (depending on climate)
  • 40,000 BTU 96% AFUE natural gas furnace
  • Requires plastic/PVC flue venting
  • Complies with Clean Air Act New Refrigerant Requirements
  • Can be used in the downflow or horizontal orientation
  • Can be converted to an LP furnace with an optional conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
SKU GLXS4BA2410
Weight 132.000000
Manufacturer Goodman
Replaces GSXN402410
Product Features New Refrigerant Compliant
Cooling BTU 24,000
Decibel Level (dBA) 74
Horsepower 1/8 HP
Refrigerant R32
SEER2 14.3
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 15 Amps
Min. Breaker Size 10.9 Amps
Tonnage 2 Ton
Connection Sweat
Height 27"
Width 26"
Depth 26"
Owner's Manual
What our Experts Think
  • Balanced comfort for small–medium homes: This system combines a **2 ton (24,000 BTU) air conditioner at ~14.3 SEER2 with a 96 % AFUE 40,000 BTU gas furnace, delivering reliable year‑round heating and cooling without oversizing equipment for typical residential spaces.

  • High‑efficiency heating saves fuel: The 96 % AFUE condensing furnace converts almost all fuel into usable heat, cutting heating costs and energy waste compared with lower‑efficiency models.

  • Good SEER2 rating for cooling: A 14.3 SEER2 cooling rating offers above‑average energy performance in its class, helping lower summer electricity bills compared with older or baseline systems.

  • Solid airflow and control: Multi‑speed ECM blower motors and staged gas or multi‑speed operation (depending on furnace variant) provide smoother temperature control, reduced cycling, quieter operation, and better humidity management than single‑stage motors.

  • R‑32 refrigerant for modern performance: Built for R‑32 refrigerant compliance, the condenser enhances cooling efficiency and lowers environmental impact compared to legacy refrigerants.

  • TXV‑equipped evaporator coil: The included CHPTA2426B3 coil with factory‑installed thermal expansion valve helps optimize refrigerant flow and improves overall cooling efficiency and comfort performance.

  • Flexible horizontal installation: Designed for horizontal or multi‑position setups, this system fits attics, crawlspaces, and tight utility areas where vertical configurations aren’t feasible.

  • Durability and peace of mind: Heavy‑gauge steel cabinets, efficient ignition systems, and long 10‑year parts + lifetime heat exchanger warranty (with registration) support long‑term reliability and lower maintenance concerns.

  • Value‑oriented choice: Experts see this configuration as a cost‑effective mid‑efficiency HVAC solution that balances heating efficiency, good cooling performance, modern refrigerant tech, and dependable comfort for everyday residential use.



Q&A

Q: What type of HVAC system is this?
A: This is a complete high-efficiency Goodman HVAC system, featuring a 2‑ton air conditioner (GLXS4BA2410), cased evaporator coil (CHPTA2426B3), and 40,000 BTU 96% AFUE gas furnace (GD9T960403BN) for reliable heating and cooling year-round.

Q: What size home is this system suitable for?
A: A 2‑ton AC system (24,000 BTU) is ideal for small to medium homes, condos, or zones around 900–1,400 sq. ft., depending on insulation, layout, and climate.

Q: How energy efficient is this system?
A: The system delivers 14.3 SEER2 cooling efficiency and a 96% AFUE gas furnace, converting nearly all fuel into usable heat for highly efficient residential comfort.

Q: What refrigerant does the air conditioner use?
A: The condenser uses R‑32 refrigerant, a modern, eco-friendly refrigerant designed to maximize efficiency and minimize environmental impact.

Q: Does the furnace include advanced technology?
A: Yes. The GD9T960403BN furnace features a variable-speed ECM blower motor, providing quieter operation, improved airflow, and consistent indoor temperatures.

Q: Can this system be installed horizontally?
A: Yes. Both the furnace and coil support horizontal airflow installation, suitable for attics, crawl spaces, or closets with limited vertical space.

Q: What components are included in this system?
A: The package includes:

  • GLXS4BA2410 – 2 Ton 14.3 SEER2 outdoor AC condenser

  • CHPTA2426B3 – 2 Ton cased evaporator coil

  • GD9T960403BN – 40,000 BTU 96% AFUE gas furnace


Maintenance Tips
  • Replace air filters every 1–3 months: Prevents dust buildup, maintains airflow, and protects the blower motor.

  • Keep the outdoor condenser clear: Maintain 2–3 ft clearance around the unit and remove leaves or debris for optimal cooling performance.

  • Inspect and clean evaporator coil and drain pan: The CHPTA aluminum coil should be checked periodically to avoid clogs, water leaks, and reduced efficiency.

  • Check refrigerant line insulation: Ensure suction line insulation is intact to maintain energy efficiency.

  • Keep vents and registers unobstructed: Allows balanced airflow for consistent heating and cooling.

  • Schedule annual professional service: A certified HVAC technician should inspect the furnace heat exchanger, blower motor, refrigerant levels, and safety controls each year.

  • Maintain a clean furnace area: Clear surrounding space to ensure safe operation and optimal airflow for the 96% AFUE furnace.

View full details