Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3026B3 

A Goodman gas furnace and air conditioner system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman gas furnace and air conditioner system is the perfect choice for all of your heating and cooling needs.

Features
  • Ideal size to cover a medium-sized house
  • 2 ton, 13.4 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Low sound output
  • Fully charged for up to 15' of line set
  • Factory-installed filter drier
  • 2.5 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
  • This furnace is ideal to heat a medium-sized house (in average climate conditions)
  • 60,000 BTU 80% AFUE two stage variable speed natural gas furnace
  • Requires metal flue venting
  • Can be used in the upflow or horizontal orientation
  • Can be converted to propane with an LP conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
2 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32
SKU GLXS3BN2410
Weight 130.000000
Manufacturer Goodman
Replaces GSX130241 and GSXN3N2410
Product Features New Refrigerant Compliant
Cooling BTU 24,000
Decibel Level (dBA) 74
Horsepower 1/8 HP
Refrigerant R32
SEER2 13.4
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208 / 230 V. 1 Phase 60 Hz
Max Breaker Size 15 Amps
Min. Breaker Size 10.9 Amps
Tonnage 2 Ton
Connection Sweat
Height 27.5"
Width 26"
Depth 26"
Manual
What our Experts Think
  • Complete Heating & Cooling System – A matched 2 ton air conditioner + 60,000 BTU, 80% AFUE gas furnace that delivers reliable year‑round comfort in smaller to mid‑size homes.

  • 14.5 SEER2 Cooling Efficiency – Meets modern energy standards for efficient summer cooling and can help reduce electricity costs compared with older systems.

  • 80% AFUE Gas Furnace – Offers dependable heating performance with a standard‑efficiency rating that balances comfort with upfront value.

  • Horizontal Installation Configuration – Designed for attic or crawl‑space setups, making it a good choice where space is limited or ductwork is horizontal.

  • R‑32 Refrigerant Ready – Designed for use with next‑generation R‑32 refrigerant, improving environmental performance and aligning with current HVAC standards.

  • Factory‑Matched Components – Engineered to work together for optimized system performance, smoother airflow, and improved reliability compared to mismatched units.

  • Simple, Service‑Friendly Design – Straightforward configuration means easier installation and routine maintenance for HVAC professionals.

  • Balanced Comfort & Value – Provides consistent cooling and everyday heating without premium costs for advanced staging or ultra‑high efficiency.


Q&A

Q: What components are included in this system?
A: A matched HVAC comfort system featuring a **2 ton 14.5 SEER2 R32 air conditioner condenser, a horizontal CHPTA3026B3 evaporator coil with factory‑installed TXV, and a 60,000 BTU 80% AFUE gas furnace designed for year‑round cooling and heating.

Q: What size home is this system best for?
A: With 2 ton (about 24,000 BTU) cooling and 60,000 BTU heating, it’s ideal for small to medium homes (~1,000–1,800 sq ft) depending on insulation, climate, and duct design.

Q: What does 14.5 SEER2 efficiency mean?
A: 14.5 SEER2 denotes solid seasonal cooling efficiency. It helps reduce electricity use and cooling costs compared to older or lower‑rated systems, while meeting current efficiency standards.

Q: What does 80% AFUE indicate for the furnace?
A: 80% AFUE means 80% of the gas energy becomes usable heat, offering cost‑effective and dependable heating performance for everyday comfort.

Q: How does the CHPTA3026B3 coil improve performance?
A: The horizontal evaporator coil with factory‑installed TXV ensures precise refrigerant metering and efficient heat transfer, enhancing overall cooling performance and reliability.

Q: What refrigerant does this system use?
A: This system uses R32 refrigerant, which provides higher efficiency and lower environmental impact compared with many older refrigerants.

Q: What installation orientation is supported?
A: It’s designed for horizontal installation, making it suitable for attic, closet, or tight mechanical room applications requiring sideways airflow.

Q: Is professional installation required?
A: Yes — licensed HVAC professionals should install and properly configure the system for safety, optimal performance, and warranty compliance.


Maintenance Tips
  • Replace Air Filters Every 1–3 Months: Maintains airflow, protects both furnace and AC components, and ensures efficient operation.

  • Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.

  • Clean Outdoor AC Condenser: Rinse coils every 3–6 months to maintain SEER2 efficiency and prevent debris buildup.

  • Annual Professional Inspection: Technicians should check burners, heat exchanger, gas pressure, and airflow for safe furnace operation.

  • Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 performance.

  • Maintain Condensate Drains: Keep both furnace and AC drain lines clear to prevent water issues or system shutdowns.

  • Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.

  • Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require immediate attention.