Skip to product information
1 of 10

Goodman - 3 Ton/36,000 BTU High Efficiency Heat Pump Condenser- 15.2 SEER2 - Single Stage - R32 - GLZS5BA3610

Goodman - 3 Ton/36,000 BTU High Efficiency Heat Pump Condenser- 15.2 SEER2 - Single Stage - R32 - GLZS5BA3610

Regular price $2,664.99 USD
Regular price $3,552.00 USD Sale price $2,664.99 USD
Sale Sold out

Description

Goodman - 3 Ton/36,000 BTU High Efficiency Heat Pump Condenser- 15.2 SEER2 - Single Stage - R32 - GLZS5BA3610

The Goodman GLZS5BA3610 heat pump condenser delivers high efficiency, helping you save money on energy bills. With its solid construction, it's perfect for a wide range of home heating and cooling needs.

Please note this is an outdoor unit only, for full system operation this needs to be paired with an indoor unit.

Features
  • Designed to cover a smaller house in average climates
  • 3 Ton, 15.2 SEER2 heat pump condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Low sound output
  • Fully charged for up to 15' of line set
  • Factory-installed bi-flow filter drier
Specifications
3 Ton 15.2 SEER2 High Efficiency Goodman Heat Pump - 7.8 HSPF2
SKU GLZS5BA3610
Weight (in lbs) 242.000000
Brand/Manufacturer Goodman
Replaces GSZ160361
Product Features New Refrigerant Compliant
Cooling BTU 36,000
Heating BTU 36,000
Decibel Level (dBA) 72
Horsepower 0.33 HP
Refrigerant R32
SEER2 (Efficiency) 15.2
Condenser Stages Single Stage
Compressor Type Scroll
Liquid Line 3/8"
Suction Line 7/8"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 35 Amps
Min. Breaker Size 22.8 Amps
Tonnage 3 Ton
Connection Sweat
Height 39 1/2"
Width 35 1/2"
Depth 35 1/2"
Manual
What our Experts Think
  • 3 Ton / 36,000 BTU Heat Pump Capacity – Well‑suited for medium‑sized homes (≈1,500–1,800 sq ft), providing balanced cooling and heating performance throughout the year.

  • 15.2 SEER2 & R‑32 Refrigerant – Meets modern efficiency standards with eco‑friendlier R‑32 refrigerant, helping reduce utility costs and environmental impact compared with older systems.

  • Single‑Stage Scroll Compressor – Simple, reliable compressor design that delivers consistent performance with easier serviceability and fewer moving parts to fail.

  • SmartShift Quiet Defrost Technology – Built‑in defrost system enhances heating performance and comfort in colder weather without loud cycling.

  • Durable Outdoor Construction – Heavy‑gauge galvanized‑steel cabinet with powder‑coat finish and coil guard resists corrosion and weathering for longer service life in outdoor conditions.

  • Easy Service Access – High‑/low‑pressure switches, accessible gauge ports, and service valves simplify installation and maintenance for HVAC pros.


Q&A

Q: What type of system is the GLZS5BA3610?
A: It’s a 3 ton (36,000 BTU) high‑efficiency heat pump condenser designed to provide both cooling and heating when paired with a compatible indoor air handler or coil.

Q: What does the 15.2 SEER2 rating mean?
A: 15.2 SEER2 (Seasonal Energy Efficiency Ratio 2) reflects efficient seasonal cooling performance, helping lower electricity use and cooling costs compared with older, lower SEER units.

Q: How does this heat pump perform in heating?
A: It delivers roughly 36,000 BTU of heating capacity and generally has a HSPF2 (Heating Seasonal Performance Factor) around 7.8, giving efficient heat transfer in moderate winter climates.

Q: What refrigerant does it use and why it matters?
A: This unit uses R32 refrigerant, which offers improved energy efficiency and lower global warming potential compared to many older options.

Q: What kind of compressor and fan does it have?
A: It includes a single‑stage scroll compressor for dependable, steady performance, and a single‑speed condenser fan motor to support consistent airflow.

Q: What are key durability and build features?
A: Its heavy‑gauge galvanized steel cabinet with powder‑coat finish, removable grille design, coil guard, ground lug, and factory‑installed protections (accumulator, crankcase heater, muffler) improve weather durability and serviceability.

Q: Is the unit pre‑charged?
A: Yes — it comes factory‑charged for up to ~15 ft of line set, simplifying installation for HVAC professionals.

Q: What installation requirements does it have?
A: It typically runs on 208/230 V single‑phase power and must be paired with a properly sized indoor air handler or coil and compatible thermostat.


Maintenance Tips
  • Keep Outdoor Unit Clear: Maintain at least 24 inches of clearance around the condenser; remove leaves, dirt, and debris to ensure proper airflow.

  • Clean Condenser Coils: Rinse coils every 3–6 months to prevent buildup that reduces SEER2 efficiency.

  • Replace Indoor Air Filters: Change filters every 1–3 months to protect the system and maintain airflow.

  • Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is not damaged for optimal R32 performance.

  • Check Condensate Drain: Keep the drain line clear to prevent water buildup or system interruptions.

  • Schedule Annual Professional Maintenance: Technicians should inspect electrical connections, refrigerant levels, fan motor, and overall heat pump performance.

  • Monitor System Performance: Unusual noises, weak heating/cooling, or rising energy bills indicate the need for prompt service.

View full details