Skip to product information
1 of 10

Goodman - 3 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3630B3

Goodman - 3 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3630B3

Regular price $3,615.99 USD
Regular price $4,821.00 USD Sale price $3,615.99 USD
Sale Sold out

Description

Goodman - 3 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3630B3 

A Goodman combination system is an excellent way to keep your home cozy in winter and cool in summer. With top-notch features and a budget-friendly price, it's a smart choice for any homeowner.

Features
  • This furnace is ideal to heat a smaller house (depending on climate)
  • 60,000 BTU 92% efficient natural gas furnace
  • Requires plastic/PVC flue venting
  • Complies with Clean Air Act New Refrigerant Requirements
  • Can be used in the upflow or horizontal orientation
  • Can be converted to an LP furnace with a conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
  • Ideal size to cover a small house in ideal climates
  • 3 ton, 14.3 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Fully charged for up to 15' of line set
  • Low sound output
  • Factory-installed filter drier
  • 3 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
Specifications
SKU GLXS4BA3610
Weight 173.000000
Manufacturer Goodman
Replaces GSXN403610
Product Features New Refrigerant Compliant
Cooling BTU 36,000
Decibel Level (dBA) 67
Horsepower 1/6 HP
Refrigerant R32
SEER2 14.3
Condenser Stages Single Stage
Compressor Type Scroll
Liquid Line 3/8"
Suction Line 7/8"
Liquid Valve Size 3/8"
Suction Valve Size 7/8"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 30 Amps
Min. Breaker Size 17.8 Amps
Tonnage 3 Ton
Connection Sweat
Height 39 1/2"
Width 29"
Depth 29"
Manual
What our Experts Think
  • High Efficiency: 92% AFUE furnace paired with 15.2 SEER2 AC provides reliable year-round comfort.

  • Optimal Capacity: 3 Ton / 60,000 BTU output ideal for medium to large homes.

  • Horizontal Installation: Designed for seamless integration into horizontal ductwork layouts.

  • Reliable Performance: Engineered for consistent, dependable heating and cooling.

  • Eco-Friendly Refrigerant: AC uses R32 to reduce environmental impact.

  • Durable Build: Built for long-term reliability across diverse climates.

  • Quiet Operation: Optimized for minimal noise in both heating and cooling modes.

Q&A

Q: What’s included in this HVAC system?
A: This matched split system bundles a Goodman 3 ton R32 central air conditioner condenser (GLXS4MA3610), a horizontal cased evaporator coil with factory‑installed TXV (CHPTA3630B3), and a 60,000 BTU 92% AFUE gas furnace (GR9S920603BN) for complete year‑round comfort.

Q: What cooling capacity and efficiency does it deliver?
A: The outdoor unit provides 3 tons (36,000 BTU) of cooling with a 15.2 SEER2 efficiency rating, helping reduce energy costs while keeping your home comfortably cool.

Q: How efficient and powerful is the heating component?
A: The gas furnace delivers 60,000 BTU input with 92% AFUE, meaning most fuel is converted into heat — ideal for small to medium homes or zones.

Q: What refrigerant does the system use?
A: Uses R‑32 refrigerant, a more environmentally responsible option with lower global warming potential than many older refrigerants.

Q: What installation orientation does it support?
A: Designed for horizontal installation (often attic or closet applications) with flexibility for installation orientation in restricted spaces.

Q: What are the key features of the evaporator coil?
A: The CHPTA3630B3 coil has an all‑aluminum design, factory‑installed TXV for precise refrigerant control, foil‑faced insulation and rust‑resistant drain pan for durability and efficient operation.

Q: What blower and control features does the furnace include?
A: The furnace features a multi‑speed ECM blower for smoother airflow and quieter operation, plus safety and diagnostic controls for dependable performance.

Maintenance Tips
  • Replace air filters every 1–3 months to maintain airflow and system efficiency.

  • Keep supply and return vents clear of furniture, dust, and debris.

  • Maintain 2–3 feet of clearance around the furnace and condenser for safe operation.

  • Inspect the condensate drain line regularly to prevent clogs and water buildup.

  • Check thermostat settings and operation for proper heating and cooling cycles.

  • Examine vent pipes, ductwork, and connections for leaks or blockages.

  • Clean blower compartment and indoor coil surfaces to reduce dust buildup.

  • Inspect the outdoor air conditioner coil periodically and remove debris to maintain efficiency.

  • Listen for unusual noises such as rattling, buzzing, or humming indicating potential mechanical issues.

  • Schedule annual professional HVAC maintenance to inspect burners, heat exchanger, refrigerant levels, and electrical components.

View full details